Search

Your search keyword '"Amy L. Throckmorton"' showing total 105 results

Search Constraints

Start Over You searched for: Author "Amy L. Throckmorton" Remove constraint Author: "Amy L. Throckmorton"
105 results on '"Amy L. Throckmorton"'

Search Results

1. Practical Comparison of Two- and Three-Phase Bearingless Permanent Magnet Slice Motors for Blood Pumps

2. Development of the Centrifugal Blood Pump for a Hybrid Continuous Flow Pediatric Total Artificial Heart: Model, Make, Measure

3. Tunable Blood Shunt for Neonates With Complex Congenital Heart Defects

4. Novel hybrid total artificial heart with integrated oxygenator

5. Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments

7. A Cross University-Led COVID-19 Rapid-Response Effort: Design, Build, and Distribute Drexel AJFlex Face Shields

8. On the path to permanent artificial heart technology: Greater energy independence is paramount

9. Technology landscape of pediatric mechanical circulatory support devices: A systematic review 2010-2021

10. Microscale impeller pump for recirculating flow in organs-on-chip and microreactors

11. Fluid–structure interaction modeling in cardiovascular medicine – A systematic review 2017–2019

12. Invited commentary: A prospective randomized trial on parents’ disease knowledge and quality of life. Shall WeChat about telehealth?

14. Multi-disciplinary Frameworks for the Treatment of Primary Cardiac Sarcoma

15. BIO27: Advancements of DragonHeart BiVentricular Assist Device

16. The newly emerging field of pediatric engineering: Innovation for our next generation

17. Integrated long-term multifunctional pediatric mechanical circulatory assist device

18. Invited commentary for asymmetric dimethylarginine (ADMA): Is it a risk factor in the repair of aortic coarctation?

19. Invited commentary: Personalized surgical planning by computational and visual methods in 21st-century medical engineering

20. Fluid-structure interaction analysis of a collapsible axial flow blood pump impeller and protective cage for Fontan patients

21. Hybrid Continuous-Flow Total Artificial Heart

22. Externally applied compression therapy for Fontan patients

24. Pediatric mechanical circulatory support-leveraging design innovation for the younger generation

25. Clinical implications of LDH isoenzymes in hemolysis and continuous-flow left ventricular assist device-induced thrombosis

26. New versatile dual-support pediatric heart pump

27. Cardiac Magnetic Resonance Imaging of Mechanical Cavopulmonary Assistance

28. Vortical flow characteristics of mechanical cavopulmonary assistance: Pre- and post-swirl dynamics

29. Physics-driven impeller designs for a novel intravascular blood pump for patients with congenital heart disease

30. A Formal Task-Analytic Approach to Medical Device Alarm Troubleshooting Instructions

31. Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century

32. Mechanical Circulatory Support of the Right Ventricle for Adult and Pediatric Patients With Heart Failure

33. Implantable Roller Pump for Heart-Failure Induced Lymphedema

34. Total Artificial Hearts-Past, Current, and Future

35. Pressure-Flow Experimental Performance of New Intravascular Blood Pump Designs for Fontan Patients

36. Using Formal Task Analytic Models to Support User Manual Development: An LVAD Case Study

37. Stereo-Particle Image Velocimetry Measurements of a Patient-Specific Fontan Physiology Utilizing Novel Pressure Augmentation Stents

38. Design of Axial Blood Pumps for Patients With Dysfunctional Fontan Physiology: Computational Studies and Performance Testing

39. Dual-Pump Support in the Inferior and Superior Vena Cavae of a Patient-Specific Fontan Physiology

40. Steady Flow Analysis of Mechanical Cavopulmonary Assistance in MRI-Derived Patient-Specific Fontan Configurations

41. Uniquely shaped cardiovascular stents enhance the pressure generation of intravascular blood pumps

42. Twisted Cardiovascular Cages for Intravascular Axial Flow Blood Pumps to Support the Fontan Physiology

43. Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century

44. Laser Flow Measurements in an Idealized Total Cavopulmonary Connection With Mechanical Circulatory Assistance

45. Mechanical Cavopulmonary Assistance of a Patient-Specific Fontan Physiology: Numerical Simulations, Lumped Parameter Modeling, and Suction Experiments

46. Flexible Impeller Blades in an Axial Flow Pump for Intravascular Cavopulmonary Assistance of the Fontan Physiology

47. Filament Support Spindle for an Intravascular Cavopulmonary Assist Device

48. Interaction of an Idealized Cavopulmonary Circulation With Mechanical Circulatory Assist Using an Intravascular Rotary Blood Pump

49. Hydraulic Testing of Intravascular Axial Flow Blood Pump Designs With a Protective Cage of Filaments for Mechanical Cavopulmonary Assist

50. Intravascular Mechanical Cavopulmonary Assistance for Patients With Failing Fontan Physiology

Catalog

Books, media, physical & digital resources