1. Anatomical Parameters of Percutaneous, Minimally Invasive, Direct Intralaminar Pars Screw Fixation of Spondylolysis.
- Author
-
Güdü BO, Aydın AL, Mercan NE, Dilbaz S, Çırak M, Öktenoğlu T, and Özer AF
- Subjects
- Humans, Female, Male, Middle Aged, Adult, Aged, Minimally Invasive Surgical Procedures methods, Tomography, X-Ray Computed, Young Adult, Spinal Fusion methods, Spinal Fusion instrumentation, Retrospective Studies, Spondylolysis surgery, Spondylolysis diagnostic imaging, Lumbar Vertebrae surgery, Lumbar Vertebrae diagnostic imaging, Bone Screws
- Abstract
Objective: To investigate the anatomical parameters of the ideal screw trajectory for percutaneous intralaminar screw fixation of a pars defect in lumbar spondylolysis using computed tomography scans., Methods: Using advanced radiological software, the ideal intralaminar screw trajectory was determined. The anatomical parameters of this trajectory were analyzed using a total of 80 single-level lumbar tomography scans in patients with spondylolysis at the lumbar 4 vertebrae and lumbar 5 vertebrae levels. The ideal intralaminar screw trajectory started from the inferolateral edge of the lamina and was between the intralaminar region, pars defect, and defective pars neck and pedicle. Along this trajectory, the skin-lamina distance, intralaminar screw length, isthmic lamina length and width, defective pars neck width, lateral entry distance of the screw to the center of the spinous process, and sagittal and coronal screw application angles were analyzed., Results: When comparing the lumbar 4 vertebrae and lumbar 5 vertebrae parameters, the mean skin-to-lamina distances were 11-9 cm (P = 0.000), intralaminar screw lengths 3.5-3.6 cm (P = 0.067), isthmic lamina lengths 2-2 cm (P = 0.698), mid-lamina widths 1-1 cm (P = 0.941), defective pars neck widths 1-1 cm (P = 0.674), screw lateral entry distances according to the spinous process 1-1.5 cm (P = 0.000), sagittal screw angles 45°-45° (P = 0.870), and coronal screw angles 10°-20° (P = 0.000), respectively. There were no differences based on age and gender (P < 0.05)., Conclusions: Percutaneous intralaminar rigid screw fixation of a pars defect in spondylolysis provides minimally invasive, low-profile instrumentation. In spondylolysis, a screw length of 3-4 cm and a screw diameter of 4-5 mm may be sufficient for pars fixation with intralaminar screws., (Copyright © 2024 Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF