201. Complications of peripherally inserted central venous catheter in Japanese neonatal intensive care units.
- Author
-
Ohki Y, Maruyama K, Harigaya A, Kohno M, and Arakawa H
- Subjects
- Cardiac Tamponade etiology, Cardiac Tamponade surgery, Device Removal, Female, Humans, Incidence, Infant, Newborn, Japan epidemiology, Male, Pericardial Effusion etiology, Pericardial Effusion surgery, Prospective Studies, Risk Factors, Thrombosis etiology, Thrombosis surgery, Cardiac Tamponade epidemiology, Catheter-Related Infections epidemiology, Catheterization, Central Venous adverse effects, Catheters, Indwelling adverse effects, Intensive Care Units, Neonatal, Pericardial Effusion epidemiology, Thrombosis epidemiology
- Abstract
Background: The aim of this study was to investigate the incidence and risk factors of peripherally inserted central venous catheter (PICC)-related complications using a multicenter case survey., Method: A prospective cohort study was carried out by 19 neonatal intensive care units (NICUs) in Japan from February 2005 to March 2007. A total of 975 case records were collected. PICC-related complications including pericardial effusion/cardiac tamponade pleural effusion/ascites, catheter removal difficulties, catheter-related bloodstream infection (CR-BSI), and symptomatic catheter-related thrombosis were collected from case record forms. As for precautions during insertion, institutions were classified into three groups: those with maximum barrier precautions; standard precautions; and no specific precautions., Results: PICC complications occurred in 27 cases (2.9%) among 946 PICC. The incidence was 1.6% for CR-BSI, and 0.1% for cardiac tamponade. CR-BSI rate per 1000 catheter-days was 1.1 with maximum barrier precautions at catheter insertion, 1.2 with standard precautions, and 1.8 with no specific precautions. Multiple logistic regression analysis showed that proximal placement (odds ratio [OR], 3.88; 95% confidence interval [CI]: 1.42-10.60, P = 0.008) and longer placement duration (OR, 1.35; 95%CI: 1.14-1.60, for each week, P = 0.0005) independently contributed to overall complications., Conclusion: The incidence of cardiac tamponade was rare in this multicenter prospective study. Longer duration and proximal placement may be risk factors for PICC complications. In this cohort, the CR-BSI rate was low irrespective of the degree of barrier precautions at insertion., (© 2012 The Authors. Pediatrics International © 2012 Japan Pediatric Society.)
- Published
- 2013
- Full Text
- View/download PDF