151. A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis
- Author
-
Keumhee C. Carriere, Joonghyun Ahn, Mirae Lee, Eun Kyung Kim, Hae Jin Kim, Yeon Hyeon Choe, Sung Ji Park, and Sung Mok Kim
- Subjects
Aortic valve ,Intraclass correlation ,Planimetry ,High resolution ,Magnetic Resonance Imaging, Cine ,Constriction, Pathologic ,Asymptomatic ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Cardiovascular Imaging ,Aged ,medicine.diagnostic_test ,business.industry ,Aortic stenosis ,Cardiac magnetic resonance imaging, Echocardiography ,Reproducibility of Results ,Magnetic resonance imaging ,Steady-state free precession imaging ,Aortic Valve Stenosis ,Middle Aged ,Magnetic Resonance Imaging ,Confidence interval ,AORTIC VALVULAR STENOSIS ,medicine.anatomical_structure ,Echocardiography ,030220 oncology & carcinogenesis ,Aortic Valve ,Original Article ,medicine.symptom ,Nuclear medicine ,business - Abstract
Objective We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and methods We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm², 0.82 ± 0.34 cm², and 0.80 ± 0.26 cm², respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.
- Published
- 2020