151. P212 Computed tomography derived left ventricular outflow tract area downgrades severity of prosthesis-patient mismatch after transcatheter aortic valve replacement
- Author
-
S Garcia, M Nunes, Miho Fukui, K Han, Mario Gössl, João L. Cavalcante, Marcus Burns, John R. Lesser, H Niikura, Lynelle Schneider, Paul Sorajja, and L Tiang
- Subjects
Body surface area ,medicine.medical_specialty ,Transcatheter aortic ,medicine.diagnostic_test ,business.industry ,medicine.medical_treatment ,Computed tomography ,General Medicine ,medicine.disease ,Prosthesis ,Computed tomographic angiography ,Aortic valve replacement ,Valve replacement ,medicine ,Radiology, Nuclear Medicine and imaging ,Left ventricular outflow tract area ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background Prosthesis-patient mismatch (PPM) is associated with poor outcomes after surgical aortic valve replacement, but evidence in the era of transcatheter aortic valve replacement (TAVR) is small. Although PPM is conventionally defined by transthoracic echocardiogram (TTE) derived indexed effective orifice area (EOAi), TTE may underestimate left ventricular outflow tract (LVOT) area when compared with cardiac computed tomography angiography (CTA). Purpose To evaluate the inter-modality (TTE vs CTA) agreement and inter-valve (balloon-expanding valve (BEV) vs. self-expandable valve (SEV)) differences in EOAi and the severity of PPM after TAVR. Methods We analyzed all patients who underwent TAVR between 2015 to 2017and who had both of CTA and TTE at 30-days after TAVR. EOAi was calculated using the continuity equation and then indexed to body surface area as per guidelines using TTE derived LVOT diameter (EOAi-TTE) or post-procedure CTA derived LVOT area (EOAi-CTA). The external LVOT diameter was measured at inflow of TAVR bioprosthetic stent frame as per recommendations. The EOAi was used to define the grading severity of PPM: None (> 0.85 cm²/m²); Moderate (0.65 to 0.85 cm²/m²); and Severe (< 0.65 cm²/m²). Paired or Student t-test and Chi-square test were used to assess the inter-modality and inter-valve difference. Results A total of 280 patients were included (the mean age, 81.2 ± 8.1 years; 48%, female). BEV was used in 150 patients (54%). The mean EOAi-TTE vs. EOAi-CTA was 1.00 ± 0.32 and 1.41 ± 0.50 cm²/m², respectively, p Conclusion EOAi-CTA was larger and downgraded the severity of PPM than the EOAi-TTE. There was no significant difference in the severity of PPM defined by post-procedure CT between patients treated with BEV and those with SEV. Abstract P212 Figure.
- Published
- 2020
- Full Text
- View/download PDF