Objective: Efficacy of thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection (CTBAD) is dependent on eliminating retrograde false lumen perfusion and remodeling the aorta. We describe the efficacy of a novel transcatheter electrosurgical technique to fenestrate the dissection flap and create a distal seal zone for TEVAR in CTBAD., Methods: A retrospective review of the Emory Aortic Database from 2016 to 2023 identified 33 patients who underwent TEVAR with intentional endovascular rupture of the dissection flap (Knickerbocker; KNICK) for CTBAD. In 11 patients, we performed transcatheter electrosurgical aortic septostomy (TECSAS) before KNICK. The technical aspects of TECSAS + KNICK are described and results compared with TEVAR + KNICK alone., Results: Dissection chronicity, aortic size, and preoperative demographics were similar between groups. Technical success was 100%, with zero stroke or paraplegia in both groups. Thirty-day mortality for TECSAS versus KNICK was 0% versus 13.6% ( P = .199). Median follow-up was shorter after TECSAS versus KNICK, although not statistically significant (14.6 months vs 21.9 months; P = .065). Elimination of retrograde false lumen perfusion (TECSAS 100% vs KNICK 68.2%; P = .035) and complete false lumen thrombosis or obliteration (TECSAS 91.9% vs KNICK 54.6%; P = .037) were more frequent after the TECSAS procedure. Aortic reinterventions were less frequent after TECSAS versus KNICK (0% vs 13.6%, P = .199), although not statistically significant., Conclusions: The addition of TECSAS to intentional endovascular rupture of the dissection flap in CTBAD improves distal seal, eliminating retrograde false lumen perfusion. This technique is a safe and precise method to fenestrate a dissection flap and optimize TEVAR in CTBAD., Competing Interests: Y.M.D. serves as a consultant for Cook Medical. W.D.J. serves as a consultant for Gore, Medtronic, Cook Medical, and Endologix. V.C.B. serves as a consultant for Edwards, Abbott, Medtronic, Boston Scientific, and Transmural Systems, Inc. B.G.L. serves as a consultant for Endospan and as a Speaker's Bureau for Medtronic. All other authors reported no conflicts of interest. The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest., (© 2024 The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF