63 results on '"Fiaschetti, V"'
Search Results
52. Surgery for fistula-in-ano in a specialist colorectal unit: a critical appraisal.
- Author
-
Sileri P, Cadeddu F, D'Ugo S, Franceschilli L, Del Vecchio Blanco G, De Luca E, Calabrese E, Capperucci SM, Fiaschetti V, Milito G, and Gaspari AL
- Subjects
- Adolescent, Adult, Aged, Colorectal Surgery, Fecal Incontinence etiology, Female, Follow-Up Studies, Hospital Units, Humans, Male, Middle Aged, Postoperative Complications, Prospective Studies, Rectal Fistula classification, Rectal Fistula etiology, Recurrence, Reoperation statistics & numerical data, Treatment Outcome, Young Adult, Digestive System Surgical Procedures methods, Rectal Fistula surgery
- Abstract
Background: Several techniques have been described for the management of fistula-in-ano, but all carry their own risks of recurrence and incontinence. We conducted a prospective study to assess type of presentation, treatment strategy and outcome over a 5-year period., Methods: Between 1st January 2005 and 31st March 2011,247 patients presenting with anal fistulas were treated at the University Hospital Tor Vergata and were included in the present prospective study. Mean age was 47 years (range 16-76 years); minimum follow-up period was 6 months (mean 40, range 6-74 months).Patients were treated using 4 operative approaches: fistulotomy, fistulectomy, seton placement and rectal advancement flap. Data analyzed included: age, gender, type of fistula, operative intervention, healing rate, postoperative complications, reinterventions and recurrence., Results: Etiologies of fistulas were cryptoglandular (n = 218), Crohn's disease (n = 26) and Ulcerative Colitis (n = 3). Fistulae were classified as simple -intersphincteric 57 (23%), low transphincteric 28 (11%) and complex -high transphicteric 122 (49%), suprasphincteric 2 (0.8%), extrasphinteric 2 (0.8%), recto-vaginal 7 (2.8%) Crohn 26 (10%) and UC 3 (1.2%).The most common surgical procedure was the placement of seton (62%), usually applied in case of complex fistulae and Crohn's patients.Eighty-five patients (34%) underwent fistulotomy, mainly for intersphincteric and mid/low transphincteric tracts. Crohn's patients were submitted to placement of one or more loose setons.The main treatment successfully eradicated the primary fistula tract in 151/247 patients (61%). Three cases of major incontinence (1.3%) were detected during the follow-up period; Furthermore, three patients complained minor incontinence that was successfully treated by biofeedback and permacol injection into the internal anal sphincter., Conclusions: This prospective audit demonstrates an high proportion of complex anal fistulae treated by seton placement that was the most common surgical technique adopted to treat our patients as a first line. Nevertheless, a good outcome was achieved in the majority of patients with a limited rate of faecal incontinence (6/247 = 2.4%). New technologies provide promising alternatives to traditional methods of management particularly in case of complex fistulas. There is, however, a real need for high-quality randomized control trials to evaluate the different surgical and non surgical treatment options. more...
- Published
- 2011
- Full Text
- View/download PDF
53. 3-5 BI-RADs Microcalcifications: Correlation between MRI and Histological Findings.
- Author
-
Fiaschetti V, Pistolese CA, Perretta T, Cossu E, Arganini C, Salimbeni C, Scarano AL, Arduini S, and Simonetti G
- Abstract
Purpose. To evaluate the correlation between MRI and histopathological findings in patients with mammographically detected 3-5 BI-RAD (Breast Imaging Reporting And Data Systems) microcalcifications and to allow a better surgical planning. Materials and Method. 62 female Patients (age 50 ± 12) with screening detected 3-5 BI-RAD microcalcifications underwent dynamic 3 T contrast-enhanced breast MRI. After 30-day (range 24-36 days) period, 55 Patients underwent biopsy using stereotactic vacuum-assisted biopsy (VAB), 5 Patients underwent stereotactic mammographically guided biopsy, and 2 Patients underwent MRI-guided VAB. Results. Microhistology examination demonstrated 36 malignant lesions and 26 benign lesions. The analysis of MRI findings identified 8 cases of MRI BI-RADS 5, 23 cases of MRI BI-RADS 4, 11 cases of MRI BI-RADS 3, 4 cases type A and 7 cases type B, and 20 cases of MRI BI-RADS 1-2. MRI sensitivity, specificity, positive predictive value, and negative predictive value were 88.8%, 76.9%, 84.2%, and 83.3%, respectively. more...
- Published
- 2011
- Full Text
- View/download PDF
54. Comparison of different dose reduction system in computed tomography for orthodontic applications.
- Author
-
Fanucci E, Fiaschetti V, Ottria L, Mataloni M, Acampora V, Lione R, Barlattani A, and Simonetti G
- Abstract
TO CORRELATE DIFFERENT CT SYSTEM: MSCT (multislice computed tomography) with different acquisition parameters (100KV, 80KV), different reconstruction algorithm (ASIR) and CBCT (cone beam computed tomography) examination in terms of absorbed X-ray dose and diagnostic accuracy.80 KV protocols compared with 100 KV protocols resulted in reduced total radiation dose without relevant loss of diagnostic image information and quality. CBCT protocols compared with 80 KV MSCT protocols resulted in reduced total radiation dose but loss of diagnostic image information and quality although no so relevant.In addition the new system applies to equipment ASIR applicable on MSCT allows 50% of the dose without compromising image quality. more...
- Published
- 2011
55. Jaw expansive lesions: population incidence and CT dentalscan role.
- Author
-
Fiaschetti V, Fanucci E, Rascioni M, Ottria L, Barlattani A, and Simonetti G
- Abstract
Aim: The aim of the study is to evaluate the incidence of different expansive lesions and the advantages of the clinical employment of Dentalscan to study bones lesions and to establish a common diagnostic path., Materials and Methods: Since January 2005 to November 2009, 3200 patients, not selected for sex or age, have undergone a CT "Dentalscan" in the department of Diagnostic Imaging, Tor Vergata University Hospital (PTV), a suspect bone pathology was found in 704 of them through the XR-orthopantomograpy (OPT). CT images were obtained with General Electric CT Light Speed multislice. Images were saved in the Advantage Workstation (GE) supported by the "Dentascan" dedicated software and by the 3D software (3D SSD). The protocol was : Slice thickness 1,25 mm, gap 0, matrix 512 × 512, 140 KV and 70 mA. All the lesions were also studied with the dedicated three-dimensional reconstructor 3D SSD. Biopsy for diagnosis was performed on all the lesions, except one (false positive with digital OPT). THE TECHNIQUE SENSITIVITY WAS ASSESSED FOR TWO IMPORTANT CLASSES: benign and malignant lesions., Results: Through CT Dentascan a detailed evaluation of the jaws lesions and their extension was obtained. 656 patients (93.1 %) out of 704 examined for a suspicious lesion on the orthopantomography had a benign lesion: (127 follicular cysts (18.2 %), 181 radicular cysts (25.1%), 93 non odontogenic cysts (13.2%), 29 fibroma (4.2%), 198 odontomes (28.2%), 24 ameloblastoma (3.6%), 4 brown tumors (0.7%), 47 (6.9%) had malignant lesions: (12 carcinoma (1.7%), 29 metastasis (4.3%), 6 sarcoma (0.8%), 1 Dentascan CT resulted to be negative (1 false positive of digital OPT). The sensitivity of the technique for both groups was 99% for benign lesions and 98% for malign lesions., Conclusions: CT Dentascan characteristics suggest to consider these techniques as the gold standard for the evaluation of jaw expansive lesions and the support of surgical planning. more...
- Published
- 2010
56. Adult intra-thoracic kidney: a case report of bochdalek hernia.
- Author
-
Fiaschetti V, Velari L, Gaspari E, Mastrangeli R, and Simonetti G
- Abstract
Introduction. Bochdalek hernia is a congenital posterior lateral diaphragmatic defect that allows abdominal viscera to herniate into the thorax. Intrathoracic kidney is a very rare finding representing less than 5% of all renal ectopias with the least frequency of all renal ectopias. Case Presentation. We report a case of a 62-year-old man who had a left thoracic kidney associated with left Bochdalek hernia. Abdominal X-ray and chest X-ray revealed dilated loops of the colon above left hemidiaphragm. Abdominal ultrasound (US) showed the right kidney with many fluid and esophytic cysts; left kidney was unfeasible to study because of the impossibility to find it. Computed Tomography (CT) basal scan demonstrated a left-sided Bochdalek hernia with dilatated colon loops and the left kidney within the pleural space. Magnetic Resonance (MR) confirmed a defect in left hemidiaphragm with herniation of left kidney, omento, spleen and colon flexure, and intrarotation with posterior hilum on sagittal plane. Conclusion. The association of a Bochdalek hernia and an intrathoracic renal ectopia is very rare, that pose many diagnostic and management dilemmas for clinicians. Our patient has been visualized by CT and MR imaging. A high index of suspicion can result in early diagnosis and prompt intervention with reduced morbidity and mortality. more...
- Published
- 2010
- Full Text
- View/download PDF
57. Mixed hepatoblastoma in a young male adult: a case report and literature review.
- Author
-
Fiaschetti V, Fiori R, Gaspari E, Crusco S, and Simonetti G
- Abstract
Hepatoblastoma (HB) is a rare malignant tumour of the liver and usually occurs in the first three years of life. Most of these tumours arise in the embryo; hence it seems to be unusual that hepatoblastoma occurs in adults and is an exceptional cause of primary malignant liver tumour in adult patients. The diagnosis is often overlooked, and patients might be diagnosed at late stages of the disease at risk of increased mortality. In this paper we report a case of a 30-year-old man with mixed hepatoblastoma and abdominal pain, hepatomegaly and fever. The patient under went noninvasive diagnostic methods: duplex scanning, Computed Tomography (CT), and Magnetic Resonance imaging (MRI). In our experience, despite the important role of histological sample provided by biopsy in defining the diagnosis, very important was the role of MRI, more than ultrasonography and enhanced CT. The MRI detects tumor features as size, margins, and ratio with neighboring organs in order to get the best surgical approach. more...
- Published
- 2010
- Full Text
- View/download PDF
58. Gallbladder agenesis and cystic duct absence in an adult patient diagnosed by magnetic resonance cholangiography: report of a case and review of the literature.
- Author
-
Fiaschetti V, Calabrese G, Viarani S, Bazzocchi G, and Simonetti G
- Abstract
Gallbladder agenesis (GA) is a rare congenital anomaly of the biliary system often associated with other congenital abnormalities. Patients become symptomatic in 23% of cases. GA is often misinterpreted as other diseases, therefore, leading to unnecessary surgery. We report a case of congenital GA associated to cystic duct absence and a biliary tract abnormality diagnosed by Magnetic Resonance with Cholangiopancreatography. more...
- Published
- 2009
- Full Text
- View/download PDF
59. Role of diagnostic imaging to malignant sinus tumors in presurgical staging.
- Author
-
Fanucci E, Fiaschetti V, Fusco N, Viarani S, Gargari M, Barlattani A, Assako EP, and Simonetti G
- Abstract
The aim of this study is to describe the current role of imaging in pre-surgical planning, reporting 25 cases of paranasal sinus tumors examined in our Institute. Between June 2006 and May 2008, we identified 25 patients with malignant tumors of the paranasal sinuses. All of the patients were evaluated with CT and/or MR exams. US were used to assess regional lymph node involvement. When necessary CT-PET scanning using FDG, was done. Diagnostic imaging is essential during the initial work-up of a patient suspected of having a paranasal sinus tumor. The role of imaging is to define the tumor extension, nodal involvement, metastases and recurrences in the postoperative patient. CT and MR imaging are the primary modalities employed; each have advantages and disadvantages but tend to be complementary. The involvement of fine bone structures is best evaluated with CT. In assessing the extent of the tumor, MR provides excellent soft tissue detail, allowing for delineation of neoplasm from surrounding inflammatory tissue and secretions. For evaluation of lymph node enlargement color-Doppler US, CT and MR provide morphologic data, while CT-PET provides metabolic data. CT-PET can be used to stage nodal and metastatic disease and for assessing the efficacy of therapy or recurrent disease. more...
- Published
- 2008
60. Low-dose CT protocol for orthodontic diagnosis.
- Author
-
Ballanti F, Lione R, Fiaschetti V, Fanucci E, and Cozza P
- Subjects
- Adolescent, Child, Cuspid diagnostic imaging, Female, Humans, Male, Maxilla, Radiation Dosage, Statistics, Nonparametric, Tomography Scanners, X-Ray Computed, Tomography, X-Ray Computed instrumentation, Malocclusion diagnostic imaging, Radiography, Dental, Digital methods, Tomography, X-Ray Computed methods, Tooth, Impacted diagnostic imaging
- Abstract
Aim: This was to correlate the dosimetric evaluation with high diagnostic accuracy by suggesting a protocol that significantly reduces the dose administered by a Dentascan exam without affecting diagnostic accuracy., Materials and Methods: 17 patients were selected consecutively (7 males and 10 females) of a mean age of 11.2 (8-14 years) who sought orthodontic treatment. They needed CT control before and after treatment with RME to evaluate impacted canines. The study was performed using a multidetector 16-rows CT with two protocols that provided 2 different KV acquisition parameters: 80 KV or 120 KV. Radiation dose was evaluated in two ways: CTDI and DLP. Image quality was rated and the results were compared to identify significant differences in terms of image quality, radiation exposure and presence of artefacts., Results: The 80 KV scanning has a significantly lower effective radiation dose compared to the 120 KV scanning (p <0.05). The images of all patients were used for comparing the protocols in terms of image quality. The mean scores for the 80 KV scanning images were 4.18 +/-0.81 and 4.41 +/-0.80 for dose obtained by 120 KV scanning. The median image quality was 4 (good) for both protocols. The 80 KV protocol allowed, as well as the 120 KV, a careful analysis by the orthodontist and the dental surgeon that together, based on this images, can choose the best line of treatment between several available options., Conclusion: 80 KV protocols compared with 120 KV protocols resulted in reduced total radiation dose without relevant loss of diagnostic image information and quality. The images were good enough to obtain information about the exact position of impacted teeth and to plan the best line of surgical treatment and mechanotherapy strategy. more...
- Published
- 2008
61. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure.
- Author
-
Fanucci E, Fiaschetti V, Rotili A, Floris R, and Simonetti G
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Clinical Protocols, Female, Humans, Italy, Male, Middle Aged, Outcome and Process Assessment, Health Care, Positron-Emission Tomography statistics & numerical data, Radiography, Time Factors, Whole Body Imaging statistics & numerical data, Emergency Service, Hospital standards, Multiple Trauma diagnostic imaging, Positron-Emission Tomography standards, Whole Body Imaging standards
- Abstract
The objective of this study was to compare two different scanning protocols in patients suspected to have multiple trauma using multidetector 16-row computed tomography (CT) to better define scanning time, imaging quality and radiation exposure. Forty-six patients, between March 2004 and March 2005, with suspected multiple trauma (cerebral, spine, chest, abdominal and pelvis) were evaluated with two different protocols: Protocol "A" 26 patients; Protocol "B" 20 patients. Protocol A consists of a single-pass continuous whole-body acquisition (from vertex to pubic symphysis), whereas Protocol B of conventional segmented acquisition with scanning of body segments individually. Both protocols were performed using a multidetector 16-rows CT (Light-Speed 16, General Electric Medical System, Milwaukee, WI, USA) with the same technical factors. Radiation dose was evaluated in two ways: computer tomography dose index (CTDI) = dose measured in central and peripheral region of the subjects as a direct result of a CT section acquisition of T millimeters thick (independent from the two protocols) and dose length product (DLP) = total dose deposited over the length of the acquisition (dependent from the two protocols). Image quality was rated according to the following scores: 1, excellent; 2, good; 3, satisfactory; 4, moderate and 5, poor. The results were compared using Wilcoxon's test to identify significant difference in terms of image quality, scanning time, radiation exposure and presence of artifacts, assuming significance at a p value of <0.05. In the single-pass scanning, DLP was 2.671 mGy x cm and a total scan time of 35 s. In whole-body protocols, we have seen artifacts due to arm adduction in thorax and less image quality in brain. In the conventional segmented study, DLP was 3.217 mGy x cm and a total scan time of 65 s; this protocol offered less extraction capabilities of off-axial on focused images of the entire spine, aorta, facial bones or hip without rescanning. Protocol A revealed a significant decrease in scan time (35 vs 65 min, p < 0.05), time in the CT examination room (21.7 vs 31.6 min.; p < 0.05), and final image analysis (83.7 vs 102.9 min; p < 0.05) and radiation dose compared to protocol B (p < 0.05). No significant difference was found for patient transport time, image reconstruction time and imaging quality. Reconstruction and isotropic reformation of axial image acquired by whole-body, single-pass protocols due to entire spine evaluation, aortic and splanchnic CT angiography eliminate additional studies. The whole-body, single-pass protocols, compared with segmented acquisitions protocols, resulted in a reduced total radiation dose without relevant loss of diagnostic image information. more...
- Published
- 2007
- Full Text
- View/download PDF
62. New technologies in breast MRI.
- Author
-
Cossu E, Fiaschetti V, Talamo M, Comes MS, Serafini G, and Simonetti G
- Subjects
- Breast Neoplasms pathology, Humans, Image Processing, Computer-Assisted, Radiographic Image Enhancement, Breast pathology, Breast Neoplasms diagnosis, Magnetic Resonance Imaging instrumentation, Magnetic Resonance Imaging methods
- Published
- 2002
63. [Breath-hold gadolinium enhanced tree-dimensional MR angiography: personal experience in the thoracic-abdominal area].
- Author
-
Maspes F, Gandini R, Pocek M, Mazzoleni C, Fiaschetti V, Marchetti Ascoli, Pistolese GR, and Simonetti G
- Subjects
- Abdomen blood supply, Gadolinium, Humans, Sensitivity and Specificity, Thorax blood supply, Aortic Diseases diagnosis, Arterial Occlusive Diseases diagnosis, Magnetic Resonance Angiography methods
- Abstract
Purpose: To investigate different clinical applications of gadolinium-enhanced MR angiography (Gd MRA) using three-dimensional breath-hold GE sequences, without bolus time calculation, in patients with vascular diseases., Material and Methods: Forty-seven patients were examined (49 studies in all). Eleven of them had an abdominal aortic aneurysm, 6 surgical bypass, 7 renal artery stenosis, 3 aortoiliac Wallstent, 7 aortic stent-graft; 11 patients had a suspected condition in the thoracic aorta and pulmonary arteries, 1 had subclavian artery stenosis and 1 suspected axillary artery compression. All patients were submitted to breath-hold Gd MRA, after 30-40 mL Gd, with a 1.5 T magnet (Gyroscan ACS-NT, Philips, The Netherlands) and a standard body coil. The GE sequences were acquired with TR = 8.8, TE = 2.7, FA = 60 degrees, matrix = 163 x 512, with 28 seconds acquisition time. Digital subtraction angiography and intraoperative findings were the reference standards to evaluate the results., Results: Thoracopulmonary district: metastatic compression of axillary vessels was found in 1 breast cancer patient; the true and the false lumens and the intimal flap were identified in 2 patients with chronic aortic dissection (Stanford A), and graft patency and complete resolution of the aortic dissection was seen in the patient operated on for acute aortic dissection (Stanford A). The thrombus, lumen, extent and diameter were studied in 2 patients with thoracic aortic aneurysms. Subclavian artery stenosis was demonstrated in 1 patient, which was treated with transluminal angioplasty and stenting. The other 6 patients had normal findings. Abdominal aortic aneurysms (AAA): as for disease extent, breath-hold Gd MRA had 100% sensitivity and specificity compared with surgical findings. Juxtarenal aneurysm extent, which had been missed at DSA, was detected in 1 patient and then confirmed at surgery. Stenosis: comparing DSA and MRA findings in the whole series of patients we had 97.4% agreement (155/159 arteries), that is 76.4% (13/17) arteries) considering only stenoses > 50%. Breath-hold Gd MRA sensitivity and specificity were 100 and 87.5%, respectively, in our 28 stenoses. Bypass, aortoiliac stent, vascular endograft: patency was demonstrated in all the 6 surgical bypass patients, and there was agreement with color Doppler findings in 5 of 6. Breath-hold Gd MRA seems to have no possible applications in the follow-up of percutaneously implanted iliac stents, but we had excellent findings about patency and position of nichel-titanium endografts used for AAA treatment., Conclusions: We optimized breath-hold 3D MRA without bolus transit time calculation and with high-dose Gd in different clinical vascular conditions. In our opinion, 3D GE sequences can replace DSA in selected cases, providing a fast, accurate and noninvasive examination. more...
- Published
- 1999
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.