551. Electrophysiologic procedures and activation of the hemostatic system.
- Author
-
Michelucci A, Antonucci E, Conti AA, Alessandrello Liotta A, Fedi S, Padeletti L, Porciani MC, Prisco D, Abbate R, and Gensini GF
- Subjects
- Adult, Aged, Electrophysiology, Female, Humans, Male, Middle Aged, Platelet Aggregation drug effects, Thrombosis blood, Blood Coagulation drug effects, Electrocoagulation adverse effects, Fibrinolytic Agents therapeutic use, Heparin therapeutic use, Thrombosis etiology, Thrombosis prevention & control
- Abstract
Background: Thromboembolism occurs in 0.4% to 2% of the subjects undergoing radiofrequency ablation (RFA), but its mechanisms remain unclear. Our aim was to evaluate several parameters of the hemostatic system in relation to the electrophysiologic procedure., Methods: Thirty consecutive patients were enrolled in the study. Fifteen underwent electrophysiologic study and 15 underwent radiofrequency ablation. Before the ablation procedure, all subjects were given an intravenous heparin bolus (2500 IU). Blood samples were drawn immediately before, at the end of, and 24 hours after the procedures. Spontaneous platelet aggregation in whole blood and in platelet-rich plasma, markers of clotting activation (prothrombin fragment 1+2 and the thrombin-antithrombin complex) and the fibrinolytic system (plasminogen activator inhibitor and D-dimer) levels were evaluated., Results: At the end of the procedure, spontaneous platelet aggregation in whole blood, prothrombin fragment 1+2, thrombin-antithrombin complex, and D-dimer levels increased significantly in all patients. The hemostatic changes were more marked after RFA than after electrophysiology. Spontaneous aggregation in whole blood, prothrombin fragment 1+2, and thrombin-antithrombin complex levels at 24 hours after the procedure were similar to those observed before the procedure in both groups; D -dimer levels were still elevated with respect to preprocedure levels, with a trend toward higher levels in patients undergoing RFA rather than electrophysiology. A significantly more marked activation of coagulation (prothrombin fragment 1+2, P <.005) was found in patients in whom the mean duration of energy application was higher than 23.5 seconds., Conclusions: Our data suggest that antithrombotic prevention with a prolonged administration of heparin and/or the association of antiplatelet agents should be considered in patients undergoing RFA.
- Published
- 1999
- Full Text
- View/download PDF