1. The Development of High Performance Pulsed Magnets of the Prototype Facility of WHMFC.
- Author
-
Li, L., Peng, T., Ding, H., Han, X., Ding, T., Qiu, L., Lv, Y., Song, Y., Duan, X., Herlach, F., and Pan, Y.
- Subjects
MAGNETS ,MAGNETIC circuits ,CAPACITORS ,STRAINS & stresses (Mechanics) - Abstract
Coils for pulsed magnets in the range of 50-75 T are developed with optimized combinations of conductors and reinforcement for the prototype laboratory of the Wuhan High Magnetic Field Center (WHMFC). The basic design tool is a Pulsed Magnet Design Software package (PMDS) for calculating the capacitor discharge, conductor heating, mechanical stresses and the residual stress, including plastic deformation and winding tension. A 1 MJ capacitor bank is equipped with a thyristor switch, a mechanical switch, polarity reversal switches, a current limiting inductor and a diode crowbar. The design and the test results of the magnets, of the protection inductance and of the capacitor bank are presented and discussed in this paper. [ABSTRACT FROM AUTHOR]
- Published
- 2010
- Full Text
- View/download PDF