1. Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients With New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement: The MARE Study.
- Author
-
Rodés-Cabau J, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, and Philippon F
- Subjects
- Action Potentials, Aged, Aged, 80 and over, Aortic Valve Stenosis epidemiology, Arrhythmias, Cardiac epidemiology, Arrhythmias, Cardiac physiopathology, Arrhythmias, Cardiac therapy, Bundle-Branch Block epidemiology, Bundle-Branch Block physiopathology, Bundle-Branch Block therapy, Canada epidemiology, Europe epidemiology, Female, Heart Rate, Humans, Incidence, Male, Predictive Value of Tests, Prospective Studies, Risk Factors, Time Factors, Treatment Outcome, United States epidemiology, Aortic Valve Stenosis surgery, Arrhythmias, Cardiac diagnosis, Bundle-Branch Block diagnosis, Electrocardiography, Ambulatory, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Objectives: The authors sought to determine: 1) the global arrhythmic burden; 2) the rate of arrhythmias leading to a treatment change; and 3) the incidence of high-degree atrioventricular block (HAVB) at 12-month follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR)., Background: Controversial data exist on the occurrence of significant arrhythmias in patients with LBBB post-TAVR., Methods: This was a multicenter prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR with the balloon-expandable SAPIEN XT/3 valve (n = 53), or the self-expanding CoreValve/Evolut R system (n = 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted at 4 (3 to 6) days post-TAVR, and patients had continuous electrocardiogram monitoring for 12 months. All arrhythmic events were adjudicated in a central electrocardiography core lab. Primary endpoints were the incidence of arrhythmias leading to a treatment change, and the incidence of HAVB at 12-month follow-up., Results: A total of 1,553 new arrhythmic events were detected in 44 patients (1,443 episodes of tachyarrhythmia in 26 patients [atrial fibrillation/flutter/atrial tachycardia: 1,427, ventricular tachycardia 16]; 110 episodes of bradyarrhythmia in 21 patients [HAVB 54, severe bradycardia 56]). All arrhythmic events were silent in 34 patients (77%), the arrhythmic event led to a treatment change in 19 patients (18%), and 11 patients (11%) required pacemaker or implantable cardioverter-defibrillator implantation (due to HAVB, severe bradycardia, or ventricular tachycardia episodes in 9, 1, and 1 patient, respectively). A total of 12 patients died at 1-year follow-up, 1 from sudden death., Conclusions: A high incidence of arrhythmic events was observed at 1-year follow-up in close to one-half of the patients with LBBB post-TAVR. Significant bradyarrhythmias occurred in one-fifth of the patients, and PPM was required in nearly one-half of them. These data support the use of a cardiac monitoring device for close follow-up and expediting the initiation of treatment in this challenging group of patients. (Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block in Patients With New-onset PeRsistent LEft Bundle Branch Block After Transcatheter Aortic Valve Implantation [MARE study]: NCT02153307)., (Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF