1. Cerebral Embolism After Transcarotid Transcatheter Aortic Valve Replacement: Factors Associated With Ipsilateral Ischemic Burden.
- Author
-
Faroux L, Junquera L, Mohammadi S, Kalavrouziotis D, Dumont E, Paradis JM, Delarochellière R, Del Val D, Muntané-Carol G, Pasian S, Ferreira-Neto AN, Pelletier-Beaumont E, and Rodés-Cabau J
- Subjects
- Aged, Aged, 80 and over, Brain Ischemia diagnosis, Diffusion Magnetic Resonance Imaging, Female, Humans, Incidence, Intracranial Embolism diagnosis, Intracranial Embolism epidemiology, Male, Prospective Studies, Quebec epidemiology, Risk Factors, Time Factors, Aortic Valve surgery, Aortic Valve Stenosis surgery, Brain Ischemia complications, Intracranial Embolism etiology, Postoperative Complications, Risk Assessment methods, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Transcarotid transcatheter aortic valve replacement (TAVR) recipients may be exposed to a higher ipsilateral subclinical cerebral ischemic burden compared with the contralateral hemisphere. We sought (1) to compare the cerebral ischemic burden of the 2 hemispheres after transcarotid TAVR, as evaluated by diffusion weighted-magnetic resonance imaging (DW-MRI), and (2) to identify the factors associated with ipsilateral ischemic burden., Methods: This prospective study included 52 patients undergoing transcarotid TAVR, followed by a DW-MRI examination. All DW-MRIs were analyzed offline by a radiologist blinded to the clinical data., Results: TAVR was performed through the left (n = 50) or right (n = 2) carotid artery. Procedural success was achieved in all patients, carotid dissection requiring patch closure occurred in 1 patient, and there were no periprocedural stroke events. At least 1 cerebral ischemic lesion was identified in the ipsilateral and contralateral hemisphere in 84.6% and 63.5% of patients, respectively (P = .005), and the number of ischemic lesions per patient was higher in the ipsilateral vs the contralateral hemisphere (2 [interquartile range, 1-5] vs 1 [interquartile range, 0-3], P = .005). The lesion volume (per lesion) and the average lesion volume (per patient) did not differ between the 2 hemispheres. A larger sheath/catheter size (≥18F vs ≤16F) was associated with a higher ipsilateral ischemic burden (P = .026)., Conclusions: Carotid artery access for TAVR was associated with a higher number of cerebral ischemic lesions in the ipsilateral (vs contralateral) cerebral hemisphere. The use of a larger sheath/delivery system (≥18F) was associated with an increased ipsilateral ischemic burden., (Copyright © 2021 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF