1. Neutron Dosimetry in Quasi-Monoenergetic Fields of 244 and 387 MeV.
- Author
-
Mares, Vladimir, Pioch, Christian, Ruhm, Werner, Iwase, Hiroshi, Iwamoto, Yosuke, Hagiwara, Masayuki, Satoh, Daiki, Yashima, Hiroshi, Itoga, Toshiro, Sato, Tatsuhiko, Nakane, Yoshihiro, Nakashima, Hiroshi, Sakamoto, Yukio, Matsumoto, Tetsuro, Masuda, Akihiko, Harano, Hideki, Nishiyama, Jun, Theis, Christian, Feldbaumer, Eduard, and Jaegerhofer, Lukas
- Subjects
- *
NEUTRONS spectra , *RADIATION dosimetry , *MONTE Carlo method , *LIQUID scintillators - Abstract
This paper describes the results of neutron spectrometry and dose measurements using a Bonner Sphere Spectrometer (BSS) at the ring cyclotron facility of the Research Center for Nuclear Physics (RCNP), Osaka University, Japan. Quasi-monoenergetic neutron fields were generated using the ^7Li (p,n)^7~\!\!Be reaction and 246 and 389 MeV protons. Neutrons produced at 0^\circ and 30^\circ emission angles were extracted into a time-of-flight (TOF) tunnel, and the energy spectra were measured at a distance of 35 m from the target. To deduce the corresponding neutron spectra from thermal to the nominal maximum energy, the BSS data were unfolded using the MSANDB code and response functions were calculated by Monte Carlo (MC) methods. These spectra are compared to spectral measurements using NE213 organic liquid scintillators applying the TOF method. The results are discussed in terms of ambient dose equivalent H^\ast (10) and compared with the readings of other instruments operated during the experiment [ABSTRACT FROM PUBLISHER]
- Published
- 2013
- Full Text