1. Clinical performance of a dedicated self-apposing stent for the treatment of left main stem disease. Results of the left Main AngioplasTy wIth a Self-apposing StEnt - the MATISSE study.
- Author
-
Cortese B, Montefusco A, D'Ascenzo F, La Manna A, Andò G, Bisceglia T, Secco GG, Meyer-Gessner M, Wańha W, Sganzerla P, Napodano M, Di Palma G, Latini RA, Tamburino C, Orrego PS, and Baumbach A
- Subjects
- Aged, Aged, 80 and over, Angioplasty, Balloon, Coronary adverse effects, Angioplasty, Balloon, Coronary mortality, Cardiovascular Agents administration & dosage, Coronary Angiography, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease mortality, Coronary Thrombosis etiology, Europe, Female, Humans, Male, Middle Aged, Myocardial Infarction etiology, Prosthesis Design, Registries, Retrospective Studies, Risk Factors, Sirolimus administration & dosage, Time Factors, Tomography, Optical Coherence, Treatment Outcome, Angioplasty, Balloon, Coronary instrumentation, Coronary Artery Disease therapy, Drug-Eluting Stents
- Abstract
Background: In the recent years percutaneous treatment of the left main stem (LM) has gained a precise role as a result of consistent scientific evidence vs. coronary artery bypass. A self-apposing stent offers an improved adaptation to the vessel wall, especially in case of tapered vessels; aim of this study was to investigate the role of a novel self-apposing, sirolimus-eluting stent (Stentys, France) for the treatment of LM coronary artery disease., Methods and Results: MATISSE is a retrospective, multicenter registry, which enrolled 151 patients treated with the device at 17 international centers. Primary study endpoint was the occurrence of major adverse cardiovascular events (MACE), a composite endpoint of cardiac death, target lesion revascularization (TLR) and target-vessel myocardial infarction, at 9months clinical follow-up. Secondary endpoints included procedural success, the single determinants of MACE and stent thrombosis. Lesions were located in distal LM bifurcation in 84% of the patients. Procedural success was achieved in 150 patients. The average follow-up length was 348±52days. MACE occurred in 14 (9.3%) patients with 2 (1.3%) cardiac deaths. TLR occurred in 8 patients (5.3%). There were 2 cases of definite stent thrombosis, 1 acute and 1 very late., Conclusions: A self-apposing stent, when used for LM PCI in a real world, high risk population, showed good immediate procedural results with low rates of adverse events at mid-term follow-up., (Copyright © 2018 Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF