1. The impact of lesion length and reference vessel diameter on angiographic restenosis and target vessel revascularization in treating in-stent restenosis with radiation.
- Author
-
Ajani AE, Waksman R, Cha DH, Gruberg L, Satler LF, Pichard AD, and Kent KM
- Subjects
- Aged, Coronary Restenosis diagnostic imaging, Coronary Restenosis mortality, District of Columbia, Double-Blind Method, Endpoint Determination, Female, Follow-Up Studies, Humans, Male, Middle Aged, Predictive Value of Tests, Reference Values, Survival Analysis, Treatment Outcome, Coronary Angiography, Coronary Restenosis radiotherapy, Coronary Restenosis surgery, Coronary Vessels radiation effects, Coronary Vessels surgery, Myocardial Revascularization, Stents
- Abstract
Objectives: The study assessed the influence of lesion length and reference vessel diameter (RVD) on recurrent restenosis after gamma intracoronary radiation therapy (ICRT) for in-stent restenosis (IRS)., Background: Intracoronary radiation therapy reduces angiographic and clinical restenosis in patients with ISR. The impact of ICRT on challenging subgroups, such as long lesions and small vessels, has not been established., Methods: Six-month quantitative coronary angiography and clinical follow-up were conducted to evaluate the influence of lesion length and RVD in patients with ISR treated with ICRT who were enrolled in gamma radiation trials. Angiographic binary restenosis (>50% diameter stenosis) and clinical events were assessed in 311 patients treated with gamma ICRT and 105 patients who received placebo., Results: Baseline demographic, angiographic and procedural details were similar in the two treatment groups. The ICRT group had reduced binary restenosis in vessels of all sizes (30% vs. 66%, p < 0.001), with the most benefit seen in small vessels. A trend toward reduced restenosis with ICRT was found across all lesion lengths. At six months, major adverse cardiac events (MACE) were reduced in the ICRT group compared to placebo (34% vs. 71%, p < 0.0001), driven by reduced target vessel revascularization (27% vs. 71%, p < 0.0001). The independent predictors of angiographic restenosis include ICRT (OR [odds ratio] 0.16; CI [confidence interval] 0.10 to 0.28, p < 0.001), lesion length (OR 1.03; CI 1.01 to 1.05, p = 0.004) and RVD (OR 0.40; CI 0.23 to 0.67, p < 0.001)., Conclusions: Intracoronary radiation therapy, compared to placebo, results in a significant reduction of angiographic restenosis across all vessel sizes, with a trend toward reduction of angiographic restenosis across all lesion lengths; this effect is seen predominantly in small vessels and diffuse lesions.
- Published
- 2002
- Full Text
- View/download PDF