1. Is the 12-lead electrocardiogram during antidromic circus movement tachycardia helpful in predicting the ablation site in atriofascicular pathways?
- Author
-
Sternick EB, Lokhandwala Y, Bohora S, Timmermans C, Martins PR, Dias LV, Correia FS, and Wellens HJ
- Subjects
- Accessory Atrioventricular Bundle physiopathology, Adolescent, Adult, Atrioventricular Node physiopathology, Brazil, Child, Child, Preschool, Female, Heart Rate, Humans, India, Male, Middle Aged, Netherlands, Predictive Value of Tests, Retrospective Studies, Tachycardia physiopathology, Young Adult, Accessory Atrioventricular Bundle diagnosis, Accessory Atrioventricular Bundle surgery, Atrioventricular Node surgery, Catheter Ablation, Electrocardiography, Tachycardia diagnosis, Tachycardia surgery
- Abstract
Aims: Unlike in the Wolff-Parkinson-White syndrome, there has been no systematic study on the role of the pre-excitation pattern in predicting the ablation site in patients with atriofascicular (AF) pathways. We assessed in a large cohort the value of the 12-lead electrocardiogram (ECG) during antidromic tachycardia (ADT) to predict the site of ablation., Methods and Results: Forty-five patients were studied, 23 males (51%), mean age of 27 ± 12 years with 46 AF pathways and 48 ADT using the AF pathway for A-V conduction. Inclusion required induction of a sustained ADT and successful ablation. Ablation site was assessed during LAO 45° projection and clockwise classified as hours in posteroseptal, posterolateral, lateral, anterolateral, and anteroseptal tricuspid annulus as follows: 05:00-07:00, >07:00-08:00, >08:00-09:00, >09:00-11:00, and >11:00-13:00 o'clock. The QRS axis was assessed during ADT and classified as normal (>+15°), horizontal (+15° to -30°), and superior (<-30°). During ADT axis was superior (-57° ± 10°) in 15 (31%), horizontal (-11° ± 14°) in 22 (46%), and normal (+45° ± 16°) in 11 (23%) patients. The correct ablation site did not differ between the different groups of QRS axis. QRS width during ADT was narrower in patients with a normal when compared with a horizontal and leftward axis (127 ± 14 vs. 145 ± 12 ms, P < 0.0001), and the V-H interval was shorter (4 ± 3 ms vs. 19 ± 22 ms, P = 0.03)., Conclusions: There was no correlation between the AF pathway ablation site and the QRS axis during ADT. The 12-lead ECG during maximal pre-excitation does not predict the proper site of tricuspid annulus ablation in patients with A-V conduction over an AF pathway., (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.)
- Published
- 2014
- Full Text
- View/download PDF