1. Building isolation from ground borne vibration.
- Author
-
Haines, Ashley
- Subjects
- *
CONVENTION facilities , *ARCHITECTURAL acoustics , *BRIDGE bearings , *ENGINEERS - Abstract
The article discusses the design of International Convention Center (ICC) in Birmingham, England. It states that one of the design criteria for ICC was perfect acoustic inspite of a main rail-line running beneath it. The final design of ICC involved over 2,000 bearings each measuring 300mm x 300mm x 125 mm deep. Although the Andre bearings were the main component of the isolation package, engineers have ensured that there were no acoustic bridges between isolated and non-isolated parts of ICC.
- Published
- 2008
- Full Text