1. Thermal defocus-free Hartmann Wavefront Sensors for monitoring aberrations in Advanced Virgo.
- Author
-
Aiello, Lorenzo, Palma, Pier Paolo, Lorenzini, Matteo, Cesarini, Elisabetta, Cifaldi, Maria, Di Fronzo, Chiara, Lumaca, Diana, Minenkov, Yury, Nardecchia, Ilaria, Rocchi, Alessio, Taranto, Claudia, and Fafone, Viviana
- Subjects
WAVEFRONT sensors ,OPTICAL aberrations ,THERMAL expansion ,BUDGET ,OPTICS - Abstract
Earth-based gravitational waves interferometric detectors are shot-noise limited in the high-frequency region of their sensitivity band. While enhancing the laser input power is the natural solution to improve on the shot noise limit, higher power also increases the optical aberration budget due to the laser absorption in the highly reflective coatings of mirrors, resulting in a drop of the sensitivity of the detector. Advanced Virgo exploits Hartmann Wavefront Sensors (HWSs) to locally measure the absorption-induced optical aberrations by monitoring the optical path length change in the core optics. Despite the very high sensitivity of Hartmann sensors, temperature fluctuations can cause a spurious curvature term to appear in the reconstructed wavefront due to the thermal expansion of the Hartmann plate, that could affect the accuracy of the aberration monitoring. We present the implementation and validation of a control loop to stabilize the Advanced Virgo HWS temperature at the order of Δ T ⩽ 0.01 K, keeping the spurious curvature within the detector's requirements on wavefront sensing accuracy. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF