22 results on '"paredes"'
Search Results
2. O método de radar de penetração no solo (GPR) na caracterização do Mosteiro da Batalha.
- Author
-
BARRACA, NUNO, MATIAS, MANUEL, and ALMEIDA, FERNANDO
- Subjects
GROUND penetrating radar ,MONASTERIES ,CONVENTS ,INFORMATION storage & retrieval systems ,CONSTRUCTION ,HISTORIC buildings - Abstract
Copyright of Conservar Património is the property of Associacao Profissional de Conservadores-Restauradores de Portugal and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
3. O método de radar de penetração no solo (GPR) na caracterização do Mosteiro da Batalha
- Author
-
Nuno Barraca, Manuel Matias, and Fernando Almeida
- Subjects
Mosteiro ,Monastery ,Characterization ,Walls ,Georradar ,Conservation ,law.invention ,lcsh:Social Sciences ,law ,lcsh:CC1-960 ,Radar ,Structured model ,Remote sensing ,Infrastructure ,Data processing ,Paredes ,Museology ,Fundações ,Georadar ,Infraestruturas ,Characterization (materials science) ,lcsh:H ,Batalha ,Ground-penetrating radar ,Caracterização ,lcsh:Archaeology ,Geology ,Foundations - Abstract
The characterization of the Monastery of Batalha included the use of the geophysical method of ground-penetrating radar (GPR), a non-destructive and indirect method that provides highresolution2D/3D images of the structures to investigate. Owing to the nature and aims of the survey, appropriate measurement grids, acquisition parameters and adapted data processing techniques were used. The GPR survey provided important information about the Monastery foundations, construction and conservation. GPR high-resolution images allowed to locate recent and ancient infrastructures, columns foundations and structures of historical-archaeological interest. The characterization of the Monastery walls was also carried out using GPR on the surface of walls of the Cloister of D. João I and of the Church. These results contribute for the proposal of an inner structure model of the walls. GPR proved to be an efficient and expeditious method that allowed obtaining information to be used in the preservation, recovery and rehabilitation of the Monument. Received: 2018-11-9Revised: 2019-1-8Accepted: 2019-1-29Online: 2019-3-18Publication: 2019-11-6, A caracterização do Mosteiro da Batalha incluiu o método de prospeção geofísica de radar de penetração no solo (GPR). Este método, não destrutivo e indireto, permite obter imagens 2D/3D de elevada resolução das estruturas investigadas. Devido à natureza do estudo, foram utilizadas grelhas de medida e parâmetros de aquisição adequados, elevada precisão da localização dos pontos de leitura e processamento de dados adaptado. O GPR clarificou questões relacionadas com a construção e o estado de conservação do Mosteiro. São apresentados resultados da investigação do terreno sob o Mosteiro, localizando infraestruturas recentes e antigas, fundações de colunas e estruturas de interesse histórico-arqueológico. A caracterização de elementos construtivos justificou a utilização do GPR na superfície das paredes do claustro de D. João I, permitindo propor uma estrutura interna do aparelho construtivo das paredes. O GPR provou ser eficaz e expedito e permitiu obter informação indispensável para contribuir para a preservação, recuperação e reabilitação do monumento. Recebido: 2018-11-9Revisto: 2019-1-8Aceite: 2019-1-29Online: 2019-3-18Publicação: 2019-3-18
- Published
- 2019
- Full Text
- View/download PDF
4. Análise numérica térmica de pilares de aço e mistos de aço e concreto em situação de incêndio visando a avaliação do método simplificado da ABNT NBR 14323: 2013
- Author
-
Jorge Munaiar, Yagho de Souza Simões, Mariana Lavagnolli Rossi, and Alessandra Lorenzetti de Castro
- Subjects
Materials science ,paredes ,Composite number ,Context (language use) ,pilares mistos de aço e concreto parcialmente revestidos ,fire resistance ,Field (computer science) ,ESTRUTURAS ,incêndio ,Column (typography) ,steel and concrete composite columns partially encased ,Thermal ,medicine ,Building construction ,business.industry ,Numerical analysis ,Stiffness ,walls ,General Medicine ,Structural engineering ,resistência ao fogo ,steel columns ,pilares de aço ,medicine.symptom ,Reduction (mathematics) ,business ,fire ,TH1-9745 - Abstract
The design of steel and steel and concrete composite columns in a fire situation is directly linked to the reduction of strength and stiffness, among other properties, which are manifested in response to rising temperatures. The normative codes that deal with the design of these elements under the action of fire consider the thermal action based on heating on the four faces of the column, an aspect that does not cover most cases in buildings due to the presence of walls. In this context, given the importance of the correct determination of the thermal field for design purposes, as well as given the simplification adopted by the normative codes, the present work deals exclusively with a study basically aimed at obtaining a representative thermal field for purposes of thermo-structural verification of steel and steel and concrete composite columns. With the focus on the analysis of cases that differ from the prescribed configurations in standards, purely thermal numerical models are proposed, validated through experimental results, whose analyses show an evident reduction in temperature in the steel column when encased with concrete, and with even greater evidence when additionally inserted into walls as a compartmentalizing element. To verify the simplified method proposed by ABNT NBR 14323: 2013, comparative analyses between the numerical thermal fields and obtained by the standardized model were carried out for steel and steel and concrete composite cross sections. For the isolated steel columns, as expected, the normative method proved to be consistent, but conservative when it came to columns inserted into walls. In relation to the composite columns, the results obtained indicate the need for adjustment in the standards for purposes of determining the thermal field and, consequently, of design these elements. RESUMO: O dimensionamento de pilares de aço e mistos de aço e concreto em situação de incêndio está diretamente atrelado à redução da resistência e da rigidez, entre outras propriedades, as quais se manifestam em resposta à elevação da temperatura. Os códigos normativos que tratam do dimensionamento desses elementos sob ação do fogo consideram a ação térmica com base em aquecimento nas quatro faces do pilar, aspecto que não abrange a grande maioria dos casos nas edificações em função da presença de paredes. Nesse mesmo contexto, dada a importância da correta determinação do campo térmico para fins de dimensionamento, bem como dada a simplificação adotada pelos códigos normativos, o presente trabalho se volta exclusivamente a um estudo basicamente direcionado à obtenção de campo térmico representativo para fins de verificação termoestrutural de pilares de aço e mistos. Tendo como foco principal a análise de casos que diferem das configurações prescritas em normas, são propostos modelos numéricos puramente térmicos validados por meio de resultados experimentais, cujas análises constatam uma evidente redução da temperatura no pilar de aço quando revestido com concreto, e ainda com maior evidência quando adicionalmente inseridos em paredes enquanto elemento de compartimentação. De modo a verificar o método simplificado proposto pela ABNT NBR 14323:2013, análises comparativas entre os campos térmicos numérico e obtido pelo modelo normatizado foram realizadas para seções transversais de aço e mistas de aço e concreto. Para os pilares de aço isolados, como esperado, o método normativo se mostrou consistente, porém conservador quando voltado a pilares inseridos em paredes. Em relação aos pilares mistos, os resultados obtidos sinalizam a necessidade de ajuste nas prescrições normativas para fins de determinação de campo térmico e, consequentemente, para fins de dimensionamento desses mesmos elementos.
- Published
- 2021
5. Avaliação de desempenho estrutural de protótipo com paredes construídas com blocos EVA
- Author
-
Marçal Rosas Florentino Lima Filho and Aluísio Braz Melo
- Subjects
Impactos ,Aggregate (composite) ,Computer science ,Paredes ,Walls ,Geography, Planning and Development ,EVA block ,Suspended piece ,Cement composites ,Civil engineering ,Prototype ,Protótipo ,Compressive strength ,Demolition waste ,Block (programming) ,Precast concrete ,Impacts ,Loads ,Cargas ,Doors ,Bloco EVA ,Peça suspense - Abstract
Resumo A utilização de resíduos de EVA (Etileno Acetato de Vinila), resultado da produção de sandálias, na construção civil tem sido objetivo de pesquisas nos últimos 10 anos. Sabe-se que tais resíduos têm grande potencial para serem empregados como agregados leves, em substituição aos agregados naturais, na elaboração de compósitos cimentícios alternativos. Este artigo, além do destaque para a evolução dos estudos de aplicação desses compósitos na produção de blocos leves, apresenta uma importante etapa do processo de avaliação de desempenho estrutural do pré-moldado proposto. As avaliações de cargas de ocupação e impactos nas paredes do protótipo construído com blocos EVA foram realizadas, através de ensaios (impactos de corpos mole e duro, solicitações transmitidas por fechamentos bruscos de porta e cargas provenientes de peça suspensa) que procuram simular situações acidentais e normais de uso de uma edificação. No processo de construção do protótipo observaram-se facilidades no uso dos blocos EVA, que são importantes na perspectiva da redução de resíduos de construção e demolição. À luz do conhecimento atual, baseando-se nos estudos anteriores e considerando-se o bom desempenho do protótipo, verificado nos ensaios realizados, sugere-se 1,2 MPa como parâmetro aceitável de resistência à compressão para o bloco EVA. Abstract The utilization of EVA (Ethylene Vinyl Acetate) waste, a byproduct from the production of sandals, in construction projects has been the object of research in the last 10 years. It is known that EVA waste has great potential to be used as lightweight aggregate, replacing natural aggregates in the production of alternative cement composites. As well as highlighting the development of research into the application of these composites in the production of light blocks, this study shows an important stage in the process of evaluation of the structural performance of the proposed precast. The evaluation of occupancy loads and impacts on the prototype walls built with EVA blocks was done through tests (impacts of soft and hard materials, repercussions of abrupt closing of doors and loads coming from suspended pieces) in order to simulate accidental and normal situations in building use. In the construction process of the prototype, the EVA blocks proved to be easy to use in ways that are important to help reducing construction and demolition waste. According to the current knowledge, based on previous studies and considering the positive performance of the prototype as shown by the tests, 1.2 MPa is suggested as an acceptable parameter of compressive strength for the EVA block.
- Published
- 2021
6. Contribuição ao estudo de paredes de concreto moldadas in loco
- Author
-
Filgueira Filho, Amâncio da Cruz, Oliveira, Romilde Almeida de, Zarzar Júnior, Fuad Carlos, and Ribeiro, Paulo Marcelo Vieira
- Subjects
Reinforced concrete ,Dissertations ,Concrete construction ,Paredes ,Walls ,Construção de concreto ,Teoria das estruturas ,Dissertações ,Concreto armado ,CONSTRUCAO CIVIL [ENGENHARIA CIVIL] ,Structural theory - Abstract
Submitted by Biblioteca Central (biblioteca@unicap.br) on 2021-05-24T14:11:40Z No. of bitstreams: 2 Ok_amancio_cruz_filgueira_filho.pdf: 10156524 bytes, checksum: c364812f8a178e6d669c3fcab88b5b5e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Made available in DSpace on 2021-05-24T14:11:41Z (GMT). No. of bitstreams: 2 Ok_amancio_cruz_filgueira_filho.pdf: 10156524 bytes, checksum: c364812f8a178e6d669c3fcab88b5b5e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2020-12-17 This research aims to bring information that contributes satisfactorily to the study of reinforced concrete walls molded in loco, addressing the history of this construction system and indications for the constituent stages of works of this nature. A greater focus was given to the structural behavior of the walls, in which buildings of 5, 15 and 45 floors were analyzed, which are buildings with the use of the construction system in the national scenario, with different typologies concerning their destination to the population. For the 5-floor typology, a comparative analysis was carried out between building on conventional concrete and cellular concrete walls since the use of the latter is in constant discussion by the technical environment. Similarly, for the 15-floor typology, a comparison was made between concrete wall and structural masonry, since they are competing methodologies and this number of floors can be considered a maximum limit for the non-use of reinforced masonry. A third analysis was carried out for a high building with concrete walls, since the number of floors defined is a value close to the highest building of this methodology in Brazil. The analyzes was carried out in software based on the calculation of the Finite Element Method (FEM), showing results, through contour maps, referring to efforts, stresses, displacements, and steel area necessary for the design. Checks for overall stability of buildings in reinforced concrete walls were carried out, as well as checks for the design of a given wall of all models analyzed. From the obtained results it can be concluded that using the calculation methods already established for structural masonry is valid, since the structural behavior of the buildings were quite similar. Regarding the building of 5 floors using cellular concrete, the analyzed wall could not be designed for compression, and limitations for its use should be reviewed. From the obtained results in this research, it seems that buildings in concrete walls have excellent behavior due to horizontal actions, since all the walls act as braces and they have a high self-weight turning out to be a set of great rigidity. Esta pesquisa tem como objetivo trazer informações que contribuam de maneira satisfatória para o estudo de paredes de concreto armado moldadas in loco, abordando-se do histórico deste sistema construtivo e indicações para as etapas constituintes de obras desta natureza. Um enfoque maior será dado para o comportamento estrutural das paredes, no qual serão analisados prédios de 5, 15 e 45 pavimentos, os quais tratam-se de edificações com utilização do sistema construtivo no cenário nacional, com diferentes tipologias no que diz respeito a sua destinação a população. Para a tipologia de 5 pavimentos será realizada análise comparativa entre de edificação em paredes de concreto convencional e em concreto celular, visto que a utilização do ultimo está em constate discussão do meio técnico. De maneira semelhante, para a tipologia de 15 pavimentos será realizada comparação entre parede de concreto e alvenaria estrutural, uma vez que são metodologias concorrentes e este número de pavimentos pode ser considerado um limite máximo para a não utilização da alvenaria armada. Uma terceira análise será realizada para um edifício alto em paredes de concreto, visto que o número de pavimentos definido trata-se de valor próximo da edificação mais alta desta metodologia no Brasil. As análises serão realizadas em software com base de cálculo no Método dos Elementos Finitos (MEF), exibindo resultados, através de mapas de contorno, referentes a esforços, tensões, deslocamentos e área de aço necessária para o dimensionamento. Serão realizadas verificações para estabilidade global das edificações em paredes de concreto armado, como também efetuadas verificações de dimensionamento de determinada parede de todos os modelos analisados. Através dos resultados obtidos pode-se concluir que utilizar os métodos de cálculo já consagrados para alvenaria estrutural é válido, pois o comportamento estrutural das edificações foi bastante semelhante. Em relação a edificação de 5 pavimentos utilizando concreto celular, a parede analisada não foi possível ser dimensionada para compressão, devendo-se rever limitações para sua utilização. Através dos resultados obtidos nesta pesquisa, constata-se que edificações em paredes de concreto possuem um excelente comportamento perante ações horizontais, uma vez que todas as paredes atuam como contraventamentos e as mesmas possuem elevado peso próprio tornando-se um conjunto de grande rigidez.
- Published
- 2020
7. AVALIAÇÃO DO DESEMPENHO ESTRUTURAL DE PAREDES DE MADEIRA LAMINADA COLADA
- Author
-
Edgar Vladimiro Mantilla Carrasco, Cynara Fiedler Bremer, and Judy Norka Rodo de Mantilla
- Subjects
avaliação da conformidade ,paredes ,Paredes de Madeira Laminada Colada ,Walls ,Paredes ,Glued Laminated Timber ,Engineering (General). Civil engineering (General) ,NA1-9428 ,madeira laminada colada ,Architecture ,Performance evaluation ,TA1-2040 ,Avaliação da conformidade ,Madeira Laminada Colada - Abstract
The objective of this work is to determine the structural performance of glued laminated timber walls using the Brazilian standard NBR 15575 (2013). Five walls with cross-section of 9 cm x 140 cm and height of 260 cm were made, 3 of these walls of Eucalyptus cloeziana and 2 of Eucalyptus grandis. The adhesive used was resorcinol formaldehyde resin base. A physical and mechanical characterization of the wood was performed before the tests. The walls were assembled from the union of 5 glued laminated timber beams of 52 cm in length. The union was made through the male-female system, using adhesive. Simple compression, soft body and hard body impact tests were performed, according to thespecifications of NBR 15575 (2013). The boundary conditions were fixed at both ends. The instrumentation consisted of load cell and 3 displacement transducers. The load application was monotonic until reaching maximum load. The results of the simple compression tests and the soft body and hard body impact tests indicate high structural performance of the glued laminated timber walls, and, therefore, meeting the specifications of NBR 15575 (2013). O objetivo deste trabalho é determinar o desempenho estrutural de paredes de madeira laminada colada utilizando a norma brasileira NBR 15575. Foram confeccionadas 5 paredes com seção transversal de 9 cm x 140 cm e altura de 260 cm, sendo 3 paredes de Eucalyptus cloeziana e 2 de Eucalyptus grandis. As paredes foram montadas a partir da união de 5 vigas de madeira laminada colada de 52 cm de comprimento. A união foi feita por meio do sistema macho-fêmea utilizando adesivo. Foram realizados os ensaios de compressão simples, corpo mole e corpo duro, conforme especificações da NBR 15575. A instrumentação foi constituída de uma célula de carga e 3 transdutores de deslocamento. A aplicação da carga foi monotônica até atingir a carga máxima estipulada. Os resultados dos ensaios de compressão simples indicam o elevado desempenho estrutural da parede de madeira laminada colada atendendo às especificações da NBR 15575. Nos ensaios de impacto de corpo mole e de corpo duro as paredes também atenderam aos critérios de desempenho especificados pela NBR 15575.
- Published
- 2020
8. Avaliação da resistência ao fogo de paredes de alvenaria de blocos cerâmicos com instalações prediais
- Author
-
Bueno, Guilherme Manfredini and González, Marco Aurélio Stumpf
- Subjects
Instalações prediais ,Aberturas ,Segurança contra incêndio ,Openings ,Paredes ,Walls ,Engenharias::Engenharia Civil [ACCNPQ] ,Fire safety ,Fire resistance ,Building installations ,Resistência ao fogo - Abstract
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2019-03-22T17:02:16Z No. of bitstreams: 1 Guilherme Manfredini Bueno_.pdf: 3882428 bytes, checksum: 21f15ed53f487897437091a0f77fdfc5 (MD5) Made available in DSpace on 2019-03-22T17:02:16Z (GMT). No. of bitstreams: 1 Guilherme Manfredini Bueno_.pdf: 3882428 bytes, checksum: 21f15ed53f487897437091a0f77fdfc5 (MD5) Previous issue date: 2019-01-17 CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior itt Performance - Instituto Tecnológico em Desempenho da Construção Civil Situações de incêndio possuem um grande potencial destrutivo para a sociedade. Um esforço significativo tem sido feito no Brasil para a avaliação da resistência ao fogo de alguns elementos. Entretanto, em relação às paredes de vedação ou com função estrutural, compostas por alvenarias de tijolos ou blocos, gesso ou concreto, há poucos estudos acadêmicos no país em escala real e ainda não foram feitas pesquisas com elementos de instalações prediais no interior de sistemas de compartimentação. Isto evidencia a importância desta pesquisa que buscou avaliar a resistência ao fogo de paredes através da ABNT NBR 10636: 1989, verificando a influência de aberturas destinadas a instalações elétricas e hidráulicas. Para atingir o objetivo proposto, foram confeccionadas amostras em escala real e ensaiadas no forno vertical do Instituto Tecnológico em Desempenho e Construção Civil (itt Performance), levando em consideração a curva de aquecimento padrão ISO 834/99 para verificação dos critérios de estabilidade, estanqueidade e isolamento térmico. A amostra referência (P-1) fora executada com blocos cerâmicos e revestimento argamassado, não possuindo instalação predial e, para fins de comparação, a amostra 2 (P-2) possuía aberturas com dimensões de 120 mm x 80 mm, contendo caixas de PVC para tomadas e componentes elétricos e a amostra 3 (P-3) aberturas de diâmetro 30 mm no ponto de saída de água das instalações hidráulicas. Durante a etapa de caracterização dos materiais, foram encontradas variações nas propriedades da argamassas utilizadas no revestimento das amostras. Conforme os resultados experimentais, todas as paredes mantiveram sua estabilidade e estanqueidade durante os 240 minutos de ensaio, entretanto, a capacidade de isolar termicamente foi comprometida em determinado instante. A P-1, P-2 e P-3 foram qualificadas como TRF 134 minutos, TRF 124 minutos e P-3 com TRF 193 minutos, respectivamente. O desempenho da amostra referência (P-1) foi comprometido devido ao desplacamento do revestimento argamassado e o lascamento dos blocos cerâmicos no decorrer do ensaio, o que também ocorreu na P-2. Logo, não se pode isolar os efeitos combinados da dilatação térmica diferencial, do desplacamento do revestimento, lascamento do substrato cerâmico, das propriedades dos materiais empregados, assim como da transferência de calor pelas aberturas nas amostras com instalações, que influenciaram no desempenho das paredes. Concluiu-se que, nas regiões com aberturas de instalações prediais que permitem a passagem de gases quentes, a superfície não exposta às altas temperaturas perde sua capacidade de isolamento em um menor tempo em comparação à superfície no entorno, o que reduz a resistência ao fogo de sistemas de compartimentação Fire situations have great destructive potential for society. A significant effort has been made in Brazil to evaluate the fire resistance of some elements. However, regarding walls, composed of masonry bricks or blocks, plaster or concrete, there are few national academic studies in full scale and no research has been done with elements of buildings built inside partitioning systems. This implies the urge of this research that sought to evaluate the performance of compartmentation walls with a fire resistance rate function, verifying the influence of openings for electrical and hydraulic installations. In order to reach the proposed objective, full scale samples were constructed and tested according to the ABNT NBR 10636:1989 in the vertical furnace of the Technological Institute in Civil Construction Performance (itt Performance - UNISINOS), taking into consideration the ISO 834/14 standard heating curve to verify stability, sealing and thermal insulation criteria. The reference sample (P-1) was performed with clay blocks and coating mortar, without any type of building installation, and for comparison purposes, sample 2 (P-2) contained openings with dimensions of 120 mm x 80 mm, containing electrical installations and sample 3 (P-3) openings of 30 mm diameter for hydraulic installations. During the materials characterization stage, there were variations in the properties of the mortars used in the coating of the samples. According to the experimental results, all systems maintained their stability and sealing during the 240 minutes of test, however, the ability to thermally insultating was compromised at a certain moment. P- 1, P-2 and P-3 were qualified as TRF 134 minutes, TRF 124 minutes and P-3 with TRF 193 minutes, respectively. The performance of the reference sample (P-1) was compromised due to the mortar coating displacement and spalling of the blocks. Therefore, it is not possible to isolate the combined effects of the thermal expansion, coating displacement, spalling of the ceramic blocks, the properties of the materials employed, as well as the heat transfer from the openings in the samples with installations, which influenced in the performance of the walls. It was concluded that in regions with openings of building installations that allow the passage of hot gases, the surface not exposed to high temperatures loses its insulation capacity in a shorter time compared to the surrounding surface, which reduces the fire resistance of the compartmentation systems.
- Published
- 2019
9. Análise das consequências da retirada de paredes na estabilidade de edifícios de quatro pavimentos construídos com alvenaria resistente estrutural
- Author
-
Oliveira, Giane Maria de Lira, Oliveira, Romilde Almeida de, Silva, Angelo Just da Costa e, and Mota, João Manoel de Freitas
- Subjects
Dissertations ,Alvenaria ,Paredes ,Walls ,Dissertações ,Masonry ,Construção civil ,CONSTRUCAO CIVIL [ENGENHARIA CIVIL] ,Construction - Abstract
Submitted by Biblioteca Central (biblioteca@unicap.br) on 2019-05-21T18:40:53Z No. of bitstreams: 1 giane_maria_lira_oliveira.pdf: 3419526 bytes, checksum: e5048d2a067409acd246d22a01515b09 (MD5) Made available in DSpace on 2019-05-21T18:40:53Z (GMT). No. of bitstreams: 1 giane_maria_lira_oliveira.pdf: 3419526 bytes, checksum: e5048d2a067409acd246d22a01515b09 (MD5) Previous issue date: 2018-10-17 In the Metropolitan area of Recife (RMR) there was an increase of masonry buildings in the 1960s, witch past time with the process that led to the production of a typology of in residential buildings of up to four floors that are locally known locally as "prédio-caixão", was widely used. This building constructed with "non-load bearing masonry" that consists of hollow ceramic bricks, or concrete blocks, with a thickness of 9 cm, seated side by side with horizontal holes. Since the 1970´ structural masonry began to be treated as an engineering technology in Brazil, through the use of structural project based on scientifically validated principles. The structural masonry is built in concrete or ceramic block, which uses industrialized pieces according to ABNT standards, join by mortar, making the set monolithic. This constructive process has as one of the characteristics the inflexibility of modification of the masonry, that is, the walls should not be demolished or opened in any ways, except for what is already established on project, or else it could cause risk of compromising the stability of the construction. This dissertation aims to analyze the impacts caused by openings in walls, in the light of the arch effect, in four-story buildings of “non-load bearing” and structural masonry, if a structure of the building to have Reinforced concrete band or not, when this opening is made in a wall located on the ground floor , and was not planned in a project. For structural analysis, computational models based on the Finite Element Method (FEM) were used, validated through analytical calculations. The application of the studied model makes it possible analyzes structural problems caused by the openings, allowing to know the behavior of the building structure. It is also possible to predict the extension of the impact of this modification in the whole structure, besides allowing us to know to what extent the building could withstand the tensions state due to the change in the path of the loads caused by the removal of part of the masonry, without collapsing. In this study, it was verified that the buildings in “non-load bearing” masonry without Reinforced Concrete band as the size of the opening increased, showed less stability and probability of collapse. Na Região Metropolitana do Recife (RMR) houve, na década de 1960, um incremento de edificações em alvenaria, que ao longo do tempo foi largamente difundido à produção de uma tipologia de edifícios residenciais, de até quatro pavimentos, que localmente são conhecidos como “Prédio-caixão”. Estes edifícios construídos com “alvenaria resistente” são feitos de tijolos cerâmicos ou blocos de concreto, vazados, com espessuras de 9 cm, e assentados com os furos na horizontal. A partir da década de 1970 no Brasil, a alvenaria estrutural passou a ser tratada como uma tecnologia de engenharia, através do projeto estrutural baseado em princípios validados cientificamente. A alvenaria estrutural é construída em bloco de concreto ou cerâmico, que utiliza peças industrializadas de acordo com as normas da ABNT, ligadas por argamassa, tornando o conjunto monolítico. Esses dois processos construtivos têm como uma das características a inflexibilidade de modificação da alvenaria, ou seja, não se deve demolir ou abrir vãos nas paredes, a não ser o que consta em projeto, sobre o risco de comprometer a estabilidade da construção. Esta dissertação tem por objetivo analisar os impactos causados por aberturas em paredes, à luz do efeito arco, em edificações de quatro pavimentos de alvenarias resistente e estrutural, com estrutura do prédio cintada e não cintada, quando essa abertura é feita em parede localizada no térreo, e que não estava prevista em projeto. Para análise estrutural foram utilizados modelos computacionais baseados no Método dos Elementos Finitos (MEF), validados através de cálculos analíticos. A aplicação do modelo estudado possibilita analisar os problemas estruturais ocasionados pelas aberturas, possibilitando conhecer o comportamento da estrutura do edifício. Pode-se ainda prever o tamanho do impacto dessa modificação na estrutura total, além de permitir conhecer até que ponto a edificação poderá suportar o estado tensional decorrente da alteração do caminho das cargas ocasionado pela retirada de parte da alvenaria, sem colapsar. Neste estudo, verificou-se que as edificações em alvenaria resistente sem cintas conforme se aumenta o tamanho da abertura apresentaram menor estabilidade e maior probabilidade de ruir.
- Published
- 2018
10. A solution to decrease the attenuation of the X-band on the sandwich walls
- Author
-
Weila Packer Pfeifer, Bravo Roger, Leonardo Lorenzo, 1962, Lintz, Rosa Cristina Cecche, Barbosa, Luísa Andréia Gachet, Sablón, Vicente Idalberto Becerra, Cruz, Térsio Guilherme de Souza, Universidade Estadual de Campinas. Faculdade de Tecnologia, Programa de Pós-Graduação em Tecnologia, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Ondas de radio - Propagação ,Paredes ,Walls ,Microwaves - Attenuation ,Radio wave propagation ,Microondas - Atenuação - Abstract
Orientador: Leonardo Lorenzo Bravo Roger Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Tecnologia Resumo: Os elementos construtivos, assim como as paredes são sempre barreiras artificiais aos sinais de radiofrequência independentemente da faixa de operação dos mesmos. O estudo aqui apresentado analisou o quanto o sistema construtivo de paredes Sandwich atenua as ondas de radiofrequência da banda X (8 a 12 GHz). Esse sistema é composto de placas armadas com malha de aço galvanizado em ambos os lados e interligadas entre si. O centro entre essa armadura é preenchido com poliestireno, sendo em ambos os lados concretado com graute ou argamassa industrial. Para efeitos comparativos, os ensaios realizados para o sistema Sandwich foram repetidos em uma parede convencional de bloco de concreto, que por ser uma parede interna de uma edificação, não fica exposta a fatores climáticos externos. Uma contribuição importante do trabalho foi oferecer uma solução para diminuir a atenuação na banda X causada pelas paredes, onde para tal foi proposto à utilização de dispositivos que não demandam a utilização de nenhum tipo de energia externa. Os dispositivos utilizados foram repetidores passivos de radiofrequência. Dois tipos foram propostos: um baseado em arranjos de antenas planares e o outro utilizando antenas cornetas. Ambas as soluções se mostraram eficientes e aplicáveis a paredes Sandwich revestidas com argamassa industrial ou graute. O repetidor de arranjo de antenas planares apresentou um ganho discreto e restrito a uma faixa estreita de frequência dentro da banda X, já o repetidor de antenas cornetas mostrou um ganho significativo em quase toda a banda, conseguindo diminuir satisfatoriamente a atenuação causada pela parede Sandwich e consequentemente melhorar os níveis de sinais recebidos através da mesma. Essa possível aplicabilidade de repetidores passivos não foi encontrada em ampla pesquisa bibliográfica realizada, destacando-se a originalidade da solução proposta. Os protótipos das antenas cornetas utilizadas no repetidor foram fabricados em uma impressora 3D, o que constitui uma importante inovação. A utilização combinada do sistema Sandwich com repetidores passivos nas paredes pode aumentar o nível de sinal disponível para as comunicações no interior das edificações em serviços que utilizam sinais de banda X, podendo essa solução ser adaptada a outras bandas de frequência, utilizando outras antenas, para resolver inúmeros problemas atuais e futuros das comunicações sem fio no interior das edificações Abstract: Constructive elements as well as walls are always artificial barriers to radiofrequency signals. Sandwich attenuates the radio frequency waves of the X band (8 to 12 GHz). This system consists of galvanized steel mesh panels on both sides and interconnected with each other. The center between this armor is filled with polystyrene, being in both sides concreted with graute or industrial mortar. For comparative comparison, the tests performed for the Sandwich system were repeated on a conventional concrete block base, which because it was an internal wall of a building, was not exposed to an external climatic model. The database was a solution for the attenuation of an anxiety dose. The devices used were passive radio frequency repeaters. Two types were proposed: a base in arrangements of planar antennas and the other using hornet antennas. The solutions are efficient and apply sandwich coated with industrial mortar or graute. The planar antenna array repeater presented a discrete gain and restricted the frequency range within the X band, since the antenna repeater horns had a significant gain in almost the entire band, being able to decrease the attenuation in a satisfactory way, consequently, the levels of received signals through it. The possibility of applying for repetitions was not found in a bibliographical research carried out, highlighting the originality of the proposed solution. The protopipes of the antenna horns are not repetitive were manufactured in a 3D printer, which is an important innovation. The combined use of the Sandwich system with safety repeats on the bars can increase the signal level available for communications within the editions on services that use X-band, Resolver in progress, and future wireless communications signals within buildings Doutorado Sistemas de Informação e Comunicação Doutora em Tecnologia CAPES
- Published
- 2018
11. Transitions between smooth and rough surfaces in turbulent channel flows for d- and k-type rough elements
- Author
-
Meletti, Gabriel Maltese de Oliveira, 1988, Franklin, Erick de Moraes, 1974, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Physics::Fluid Dynamics ,Rough elements ,Paredes ,Walls ,Turbulent boundary layer ,Surface transition ,Closed-conduit flow ,Artigo original - Abstract
This paper presents an experimental study on the transition from smooth to rough walls, and back to the smooth one, in turbulent closed-conduit flows. These transitions cause a shift on flow velocity profiles that changes their parameters when compared to the flow over a smooth wall. Different water flow rates were imposed in a closed conduit of rectangular cross section, where rough elements consisting of cavities of d- and k-type were positioned covering a part of the bottom wall of the test section. Reynolds numbers based on the channel half-height were moderate, varying between 7800 and 9600, and the regime upstream of the rough elements was hydraulically smooth. Experimental data for this specific case remain scarce and the involved physics rests to be understood. The flow field was measured by low frequency PIV (particle image velocimetry) and by flow visualization, the latter using a continuous 0.1 W laser, a high-speed camera, and scripts written by the authors. From the instantaneous fields measured with PIV, the mean velocities, fluctuations, shear stresses, and turbulence production were computed. The results show the presence of oscillations in Reynolds stress and turbulence production, that are higher for the k-type roughness and were not shown in previous experimental works. From the high-speed movies, the angular velocities and frequencies of vortices in the cavities were computed, and the occurrence of fluid ejection from the cavities to upper layers of the flow was observed. A relation between the angular velocities of inner-cavities vortices and the oscillations in Reynolds stress and turbulence production is proposed FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQ Fechado
- Published
- 2018
12. Comportamento ao fogo de paredes de alvenaria estrutural de blocos de betão com alvéolos verticais
- Author
-
Lopes, Rúben Filipe Rosa, Pereira, João Miguel, and Rodrigues, João Paulo Correia
- Subjects
resistência ao fogo ,paredes ,blocos ,argamassa ,blocks ,mortar ,walls ,structural masonry ,fire resistance ,alvenaria estrutural - Abstract
Dissertação de Mestrado em Segurança aos Incêndios Urbanos apresentada à Faculdade de Ciências e Tecnologia As alvenarias ocupam o seu lugar na história da humanidade há vários séculos e são usadas para a construção de edifícios, monumentos e obras de arte. Estas são compostas por unidades de alvenaria que são ligadas entre si com argamassa.O aparecimento do betão armado e do aço estrutural, a criação de regulamentos para a aplicação destes materiais e a rapidez com que se constrói com eles, veio deixar as paredes de alvenaria para a função de compartimentação e enchimento na construção de edifícios um pouco em todo o mundo, não sendo isto uma situação isolada do nosso país. Em Portugal, durante vários anos, não houve qualquer regulamento sobre a construção em alvenaria estrutural até ao aparecimento do Eurocódigo 6, sobre a forma da NP EN 1996, o que poderá ter contribuído para crescente uso de estruturas porticadas de betão armado e aço estrutural em vez do uso de alvenarias com capacidade estrutural.Este trabalho de investigação tem como foco principal a investigação do comportamento à ação acidental fogo de paredes de alvenaria estrutural com blocos de betão com furação vertical, tendo sido necessário numa fase inicial deste trabalho caracterizar corretamente as propriedades termomecânicas dos materiais a utilizar nas alvenarias (betão das unidades de alvenaria e argamassa), tanto a temperatura ambiente como a altas temperaturas. Após a correta caraterização dos materiais, numa fase posterior do trabalho, avaliou-se o comportamento de paredes de alvenaria à escala reduzida sujeitas a diferentes níveis de carga no plano da parede e à curva de incêndio padrão ISO 834. O objetivo pretendido foi a avaliação dos parâmetros de resistência ao fogo das alvenarias (resistência estrutural, isolamento térmico e estanquicidade à passagem de fumos e gases quentes) e a instabilidade destas, quando sujeitas à ação acidental fogo.O estudo de paredes de alvenaria estrutural com blocos de betão com alvéolos verticais ou horizontais sujeitas à ação acidental fogo já tem alguns anos, mas muito falta fazer para caraterizar corretamente estas. Essa foi a premissa para a realização desta dissertação de mestrado. A investigação que dá origem a esta dissertação foi realizada no Laboratório de Estruturas, Mecânica Estrutural e Construções do Departamento de Engenharia Civil da Faculdade de Ciências e Tecnologias da Universidade de Coimbra, em colaboração com a Universidade do Minho. Masonry occupies its place in mankind history for several centuries now and they are used for the construction of buildings, monuments and works of structural art. These are composed of masonry units that are joined together with mortar.The appearance of reinforced concrete and structural steel, the creation of codes for application of these materials, and the speed which they are built, have left masonry walls for the partition and filling functions in buildings, a little allover the world, so Portugal isn’t an isolated case. In Portugal, for several years, there wasn’t any code for structural masonry constructions until the appearance of Eurocode 6, conveyed by NP EN 1996, which may have contributed to the increasing use of frame structures of reinforced concrete and structural steel instead of using masonry with structural capacity.This research work has its focus in investigating the behavior of structural masonry walls with vertical hollowed concrete blocks to accidental fire action, it was necessary in an initial phase of this work to characterize correctly the thermo-mechanical properties of the materials being used in the masonry (masonry units concrete and mortar), both at room temperature and at high temperatures. After correct characterization of the materials, at a later stage of the work, the behavior of the reduced-scale masonry walls, subjected to different load levels at wall in-plane and to the ISO 834 standard fire curve was evaluated. The objective was to assess the resistance parameters to fire (structural strength, thermal insulation and integrity to the passage of hot fumes and gases) and their instability when subjected to accidental fire action.Structural masonry walls of vertical or horizontally hollowed concrete blocks subject to accidental fire action have been studied for many years, but there is a lot of studies to do to properly characterize them. This was the premise for the accomplishment of this master's dissertation. The research that gave origin to this dissertation was carried out in the Laboratory of Structures, Structural Mechanics and Constructions of the Department of Civil Engineering of the Faculty of Sciences and Technologies of the University of Coimbra, in collaboration with the University of Minho.
- Published
- 2017
13. Caracterização tipológica e mecância de paredes de alvenaria de pedra em centros urbanos antigos - Caso de estudo de Viseu
- Author
-
Domingues, José Carlos Mendes, Negrão, João Henrique Jorge de Oliveira, and Ferreira, Tiago Miguel dos Santos
- Subjects
alvenaria ,macacos planos ,paredes ,pedra ,masonry ,stone ,walls ,flat-jack ,Viseu - Published
- 2017
14. Desempenho acústico de soluções construtivas
- Author
-
Vasconcelos, João David Ribeiro de and Lopes, Duarte Barroso
- Subjects
Vidros ,Frames ,Paredes ,Walls ,Construções ,Acoustics ,Acústica ,Caixilharia ,Glazing - Abstract
Submitted by Ana Rebelo (amsr@isep.ipp.pt) on 2018-06-05T09:45:40Z No. of bitstreams: 1 DM_JoaoVasconcelos_2017_MEC.pdf: 14994358 bytes, checksum: 8869db6c0702dabbbe615792aa0a0608 (MD5) Approved for entry into archive by Ana Rebelo (amsr@isep.ipp.pt) on 2018-06-05T09:46:18Z (GMT) No. of bitstreams: 1 DM_JoaoVasconcelos_2017_MEC.pdf: 14994358 bytes, checksum: 8869db6c0702dabbbe615792aa0a0608 (MD5) Made available in DSpace on 2018-06-05T09:46:18Z (GMT). No. of bitstreams: 1 DM_JoaoVasconcelos_2017_MEC.pdf: 14994358 bytes, checksum: 8869db6c0702dabbbe615792aa0a0608 (MD5) Previous issue date: 2017
- Published
- 2017
15. Estratégias de Minimização de Pontes Térmicas em Paredes com Estrutura Metálica Leve
- Author
-
Costa, Vítor Diogo Pedro and Santos, Paulo Fernando Antunes dos
- Subjects
Edifícios ,Parametric study ,Paredes ,Walls ,Estratégias de mitigação ,Estrutura metálica leve ,Thermal bridges ,Mitigation strategies ,Pontes térmicas ,LSF ,Estudo paramétrico ,Light steel structure ,Buildings ,Metodologias de avaliação ,Assessment methodologies - Abstract
Dissertação de Mestrado em Engenharia Civil, na especialidade de Construções, apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra. Atualmente, a construção em aço leve, também denominada por Light Steel Framing (LSF), começa a ganhar força em edifícios habitacionais não só por toda a Europa, mas também em Portugal. Nestes edifícios com estrutura metálica, as pontes térmicas originadas pela elevada condutibilidade térmica do aço, necessitam ainda de mais atenção no sentido de as mitigar, visto que este é um material com piores características térmicas quando comparado com os materiais mais tradicionais como o betão ou o tijolo. As perdas de calor originadas pelas pontes térmicas podem representar uma importante parcela da energia consumida para aquecimento (30%), podendo estas serem superiores aos benefícios extraídos da utilização de coletores solares térmicos para produção de água quente sanitária. Ao longo desta dissertação são estudadas algumas estratégias de minimização de pontes térmicas em edifícios com estrutura metálica leve constituída por perfis enformados a frio. Para além da revisão do estado da arte sobre esta temática, analisa-se o valor do coeficiente de transmissão térmica de cada elemento, verificando-se assim qual a variação deste parâmetro térmico após a implementação de cada uma destas estratégias. Esta análise foi feita com o auxílio de um software de cálculo em elementos finitos, “THERM”, que foi também sujeito a uma validação ao longo deste trabalho. Com este trabalho conseguiram obter-se melhorias no comportamento térmico do elemento parede numa estrutura em LSF, sendo a espessura de isolamento térmico e a posição deste, os dois fatores mais preponderantes para a melhoria do seu comportamento térmico. Além disso, foi possível quantificar o erro das duas metodologias de cálculo do coeficiente de transmissão térmica (U), consoante o tipo de estrutura estudada. Currently, the construction of lightweight steel, also called Light Steel Framing (LSF), starts to gain momentum in residential buildings not only across Europe but also in Portugal. In these buildings with steel structure, thermal bridges caused by the high conductivity of the steel, need further attention in order to be mitigated as this is a material with poorer thermal characteristics when compared to more traditional materials such as concrete or brick. Heat losses arising from thermal bridges may represent a significant portion of the energy consumed for heating (30%) at the point that these may be greater than the benefits derived from the use of solar thermal collectors for domestic hot water. Throughout this thesis, some minimization strategies of thermal bridges in buildings with light steel structure consisting of cold the shaped profiles were studied. In addition to reviewing the state of the art about this issue, it was analyzed the value of heat transfer coefficient of each element, checking up the variation of this thermal parameter after the implementation of each one of these strategies. This analysis was done with the aid of a calculation software for Finite Element, "THERM", which was also subject to a validation throughout this work. This work managed to obtain improvements in the thermal behaviour of a wall in LSF structure, with the thickness of insulation and his position revealing to be the most preponderant factors to obtain improvements in the thermal parameters. Furthermore, it was managed to understand which were the errors of the two calculation methods of U-value, depending on the type of structure studied.
- Published
- 2016
16. Treatment of rising damp in walls through chemical barriers by gravity
- Author
-
Socoloski, Rafaela Falcão and Masuero, Angela Borges
- Subjects
Treatment ,Rising damp ,Paredes ,Walls ,Chemical barrier ,Tratamento contra umidade - Abstract
A umidade nas edificações pode ser proveniente de diversas fontes. Entre elas está a umidade ascensional, que provém do solo na ausência ou falha de barreiras. A umidade ascende pelas paredes por capilaridade existente devida a estrutura porosa dos materiais de construção. Sua ação pode prejudicar o desempenho das paredes das edificações, possibilitando a degradação progressiva das paredes. Dessa forma, estas podem deixar de cumprir funções, como por exemplo, de proteção e acabamento. Vários tratamentos têm sido estudados pelo mundo. Entretanto a avaliação dos métodos de reparação das paredes afetadas tem sido um problema de difícil resolução. O objetivo deste trabalho é a avaliação da eficiência do tratamento de paredes com umidade ascensional através do método de corte hídrico por inserção do cristalizante através da ação gravitacional, utilizando os diferentes produtos disponíveis no mercado nacional brasileiro. Apesar de limitada a paredes pouco espessas, essa técnica tem apresentado eficácia, versatilidade de execução e baixa interferência na fachada da parede. Essas características justificam a escolha dessa técnica para servir de objeto de estudo do presente trabalho. Visto que não há ensaio normalizado para avaliar a eficiência dos produtos para tratamento contra umidade ascensional será utilizado como referência um experimento realizado por outros pesquisadores, explanado neste documento. A avaliação da umidade presente no corpo de prova é através da medição da massa e imagens com câmera termográfica. Constatou-se que, no período analisado, não houve a redução total da umidade ascensional, no entanto os cristalizantes conseguiram diminuir consideravelmente (em média mais que 50%) a absorção da água por capilaridade. Dampness in buildings can be derived from several sources. Among them is the upward moisture, which comes from the soil in absence of barriers. The moisture ascends on the walls due to the existing capillarity of porous building materials. Its action may impair the performance of the walls of buildings, leading to their progressive degradation. Thus, the walls may cease to comply with their functions, such as protecting and finishing. Several treatments have been studied worldwide. However, evaluating the methods of repairing affected walls has been a difficult problem to be solved. The aim of this study is to evaluate the efficacy of the treatment of walls presenting upward moisture through the method of the crystallizing insertion through gravitational action using different available products within the Brazilian market. In spite of being limited to thin walls, this technique has presented efficacy, versatility of execution and little interference on the treated facade as it has been demonstrated on the studied bibliography. These features justify choosing that technique to be studied in the present work. A reference experiment conducted by other researchers is used, since there is no standard test to evaluate the efficiency of treatment products rising damp against. The evaluation of the moisture present in the specimen is by measuring the mass and images with thermographic camera. It was found that in the period analyzed, there was no reduction of the total moisture upward. However the crystallizing managed to reduce significantly (on average more than 50%) the absorption of water by capillarity.
- Published
- 2015
17. Ocorrência de fungos em paredes de alvenaria no ambiente hospitalar: estudo de caso
- Author
-
Souza, Washington Batista de and Matoski, Adalberto
- Subjects
Aerosols ,Higiene do trabalho ,Hospitais - Saneamento ,Paredes ,Walls ,Fungi ,Nosocomial infections - Prevention ,Humidity ,Infecção hospitalar - Prevenção ,Masonry - Testing ,Hospitals - Sanitation ,Alvenaria - Testes ,Aerossóis ,Engenharia civil ,Civil engineering ,Fungos ,Umidade ,Industrial hygiene - Abstract
O ambiente hospitalar é um local que requer cuidados especiais. No caso de reformas e até mesmo construções um cuidado maior é necessário, já que demolições, lixamentos e outros tipos de intervenções podem gerar aerossóis. Nos aerossóis estão presentes fungos que ao serem inalados por pacientes imunocomprometidos ou transplantados apresentam grande probabilidade de provocar infecções graves, que em muitos casos são letais. Face ao exposto, o presente trabalho tem como objetivo caracterizar a ocorrência de fungos em argamassas de revestimento no ambiente hospitalar. A pesquisa foi realizada em paredes de alvenaria do Hospital de Clínicas, da Universidade Federal do Paraná, de onde foram extraídas amostras da região da superfície, da argamassa e do bloco cerâmico. As amostras foram semeadas em placas de Petri e RODAC® contendo Ágar Sabouraud Dextrose e incubadas a 25oC durante sete dias. Após esse período o crescimento de fungos nas placas foi analisado. A variação da temperatura e umidade foi monitorada por meio de sistema remoto e manual. A argamassa dos ambientes avaliados teve seus valores de resistência à tração e teor de umidade determinados. Das 150 amostras coletadas 39% apresentaram crescimento positivo com a seguinte distribuição de fungos: Aspergillus (presente em 28% das amostras), Absidia (21%), Cladosporium (18%), Rhizopus (10%), Rhodotorulla (8%), Fusarium (6%), Penicillium (3%), A. flavus, demais fungos e outros fungos filamentosos (2%) cada. Nos substratos do interior das paredes pesquisadas foram identificadas três espécies diferentes de Aspergillus: A. flavus, A. fumigatus e A.niger. Todas as espécies de Aspergillus encontradas podem causar aspergilose invasiva e, por isso, oferecem sérios riscos à saúde de pacientes imunocomprometidos. Em uma das paredes avaliadas o teor de umidade encontrado foi igual a 12% e a resistência à tração foi nula. O estudo evidenciou a presença de fungos oportunistas, tais como Aspergillus e Fusarium, tanto nas amostras de argamassa quanto nas de bloco cerâmico retiradas do interior das paredes dos ambientes pesquisados. The hospital is a place that requires special care. In terms of reforms and even buildings, this site requires even greater care since, demolition, sanding and other types of interventions can generate aerosols. In aerosols, commonly called dust, fungi are present is high the probability of the fungi be aspirated by immunocompromised patients in a hospital. This microorganisms can germinate and cause severe infections and lethal in many cases. The present work has as its object to identify and characterize the occurrence of fungi in mortar coating in the hospital environment. The survey was conducted in masonry walls of the Clinics Hospital, Federal University of Paraná, in which were extracted samples of the surface, of the mortar and of the ceramic block. Samples were plated on Petri plates containing Sabouraud Dextrose Agar, incubated at 25 ° C for seven days, and after this period was analyzed fungal growth. The environments had their temperature and humidity monitored by a remote and manual system during one year. The mortar coating these environments was also investigated with respect to tensile strength and moisture content. Of the samples collected 39% showed growth of colonies with the following distribution of microorganisms: Aspergillus (28% of the samples), Absidia (21%), Cladosporium (18%), Rhizopus (10%), Rhodotorulla (8%), Fusarium (6%), Penicillium (2%), A. flavus, other genera and other filamentous fungi (2%). Within the substrate researched were identified three different species of Aspergillus: A. A.flavus, A.fumigatus and A.niger. All species of Aspergillus found cause invasive aspergillosis and therefore offer a serious risk to immunocompromised patients. In one of the walls evaluated the moisture content was equal 12% and the tensile strength was zero. The study revealed the presence of opportunistic fungi such as Aspergillus, Fusarium, among others, in the mortar and in the ceramic block inside the wall of the environments studied.
- Published
- 2014
18. EFECTOS DE LA RELACIÓN LARGO/ANCHO DEL DIAFRAGMA EN LA DETERMINACIÓN DE LA DEMANDA SÍSMICA EN EDIFICACIONES REGULARES DE PÓRTICOS Y MUROS PORTANTES
- Author
-
Poveda Salamanca, Carlos Eduardo and Jerez Barbosa, Sandra (dir)
- Subjects
Estructuras ,Paredes ,Walls ,Earthquakes ,Sismos ,Structures - Abstract
En Colombia como en otros países del mundo, al momento de diseñar edificaciones algunas veces se asume que los sistemas de entrepiso son rígidos, independientemente de su tipología, geometría y otras características relevantes, que podrían llevarlos a presentar otro tipo de comportamiento ya sea semirígido o flexible de acuerdo con las prescripciones establecidas en los diferentes códigos de diseño; esto se ha podido comprobar en diferentes investigaciones realizadas en el tema .., que permiten evaluar la flexibilidad del diafragma y por consiguiente la demanda sísmica obtenida del mismo., In Colombia as in other countries of the world, when designing buildings it is sometimes assumed that the mezzanine systems are rigid, regardless of their typology, geometry and other relevant characteristics, which could lead them to present another type of behavior, be it semi-rigid or flexible according to the prescriptions established in the different design codes; this has been proven in different investigations carried out in the subject ..., which allow to evaluate the flexibility of the diaphragm and therefore the seismic demand obtained from it., Especialización, Especialista en Estructuras
- Published
- 2013
19. A madeira na edificação de paredes
- Author
-
Fonseca, I., Saporiti Machado, J., João H. Negrão, and Alfredo G. Dias
- Subjects
Estruturas de madeira ,Paredes ,Walls ,Wattle and daub ,Tabique ,Timber structures - Abstract
A madeira sempre existiu em abundância no território nacional. Como material único ou conjugada com outros, a madeira assumiu um papel importante na construção de cidades como Lisboa, Guimarães, Porto ou Lamego. De facto, a imagem urbana de muitas áreas resulta, principalmente, da utilização de madeira na construção de segundos ou terceiros pisos e da possibilidade de edificar trapeiras e mansardas sobre as coberturas. Também, em zonas piscatórias, a madeira foi o material escolhido para a edificação sobre estacaria ou, mais recentemente, sobre fundações de betão. O presente artigo, inserido no âmbito de uma dissertação de doutoramento na Universidade de Évora e em colaboração com o Laboratório Nacional de Engenharia Civil, pretende dar a conhecer a riqueza e diversidade dos sistemas construtivos de paredes interiores e exteriores em que a madeira é o principal material. Na maioria das vezes, o seu esqueleto é cheio com alvenarias de tijolo ou pedra e argamassas de terra ou areia e cal. Exteriormente, é protegido com rebocos, lousas em escama ou chapas onduladas pintadas. Wood has always existed abundantly in the Portuguese territory. Either used as a single material or in combination with others, it has taken a major role in urban constructive sceneries such as Lisboa, Guimarães, Porto or Lamego. In fact, it has been a key factor in the overall image of such urban areas as it was frequently used in second and third floors build ups as well as in dormers and top roof lofts. Also, in fishing areas, wood can be widely found on buildings on piles or, more recently, on concrete foundations. This research, included as part of a doctoral dissertation at the University of Évora with the collaboration of National Laboratory for Civil Engineering, aims to reveal the richness and diversity of partition and external wall constructive systems where wood is the main material. In most cases, the skeleton is filled in with brick, masonry, earth, sand and lime mortars, and on the outside it is finished with plaster, flake slates or painted corrugated iron sheet. The article proposes to explore the different building systems. 4 1 8 DE/NEM 2011 7 a 9 de Junho
- Published
- 2011
20. Análise da transferência de calor em paredes compostas por diferentes materiais
- Author
-
Rosane Varnier, Ricardo Forgiarini Rupp, Luciano Pivoto Specht, Pedro Augusto Pereira Borges, and MEC (bolsa PET)
- Subjects
Mathematical modelling ,lcsh:T ,Walls ,Paredes ,Geography, Planning and Development ,Transferência de calor ,lcsh:Technology ,lcsh:TH1-9745 ,Energy efficiency ,Heat transfer ,Modelagem matemática ,Eficiência energética ,lcsh:Building construction - Abstract
O projeto de edificações energeticamente eficientes necessita de conhecimentos sobre a transferência de calor proveniente do ambiente externo, a fim de criar soluções que associem diferentes materiais e espessuras às condições desejadas de conforto térmico. O objetivo deste trabalho é avaliar diversos tipos e disposições de materiais em paredes de tijolos maciços, sob a ótica da térmica de edifícios. Para a realização dos experimentos, modelos em escala real foram confeccionados, instrumentados e acoplados a uma câmara térmica, desenvolvida especialmente para esse fim. O problema de transferência de calor foi modelado pela equação da energia, resolvida em Diferenças Finitas Centrais, utilizando-se o Método Implícito. As difusividades térmicas dos materiais foram calculadas resolvendo o Problema Inverso de transferência de calor. Também foi calculado o fluxo de calor e o custo total de cada alternativa, finalizando-se com a obtenção da relação termoeconômica para cada parede. Através da análise termoeconômica pode-se constatar que, apesar de o investimento inicial ser relativamente maior nas paredes mais espessas e/ou com isolamento térmico, estas apresentam um comportamento térmico muito superior às tradicionais. Notadamente, a parede com EPS na face exterior apresentou o melhor desempenho. The project of efficient energy buildings requires knowledge about heat transfer from the external environment, in order to create solutions that combine different materials and thicknesses to the desired conditions of thermal comfort. The objective of this work is to assess, from de viewpoint of buildings physics, several types and materials arrangement on solid brick walls. For the achievement of the experiments, full-scale models were fabricated, instrumented and coupled to a heat chamber, developed especially for this purpose. The heat transfer problem was modelled by energy equation, solved in Central Finite Differences using the Implicit Method. The thermal diffusivities of the materials were calculated by solving the Inverse Problem of heat transfer. It was also calculated the heat flow and the total cost of each alternative, ending with the achievement of thermo-economic relation to each wall. Through the thermo-economic analysis, it can be verified that although the initial investment is relatively higher on the thicker walls and/or with thermal insulation, these present a much higher thermal behaviour in comparison to the traditional ones. Notably, the wall with EPS on the external surface presented the best performance.
- Published
- 2010
21. Comportamento ao fogo de paredes de alvenaria estrutural de blocos de betão com alvéolos verticais
- Author
-
Lopes, Rúben Filipe Rosa, Pereira, João Miguel, and Rodrigues, João Paulo Correia
- Subjects
resistência ao fogo ,paredes ,blocos ,argamassa ,blocks ,mortar ,walls ,structural masonry ,fire resistance ,alvenaria estrutural
22. Comportamento sísmico de um sistema log-house
- Author
-
Araújo, João P., Branco, Jorge M., and Universidade do Minho
- Subjects
Earthquake ,Cyclic tests ,Paredes ,Walls ,624.042.7 ,Ensaios cíclicos ,Comportamento no plano ,Sismos ,In-plane behavior ,Log-house - Abstract
Dissertação de mestrado (ciclo de estudos integrado em Engenharia Civil), A madeira, enquanto material de construção, já ocupou no passado um lugar de destaque. Contudo, o aparecimento de outros materiais, como o aço e o betão, levou quase ao seu abandono total para fins estruturais. Excepção a esta tendência viveu-se nos países do Norte e Centro da Europa, sendo exemplo o sistema construtivo “Log-house”. Este sistema construtivo consiste na construção de paredes através da sobreposição de troncos de secção circular ou rectangular, geralmente possuindo nas faces superior e inferior um entalhe de forma a aumentar a superfície de contacto e a estabilidade. As paredes que constituem este sistema construtivo conferem-lhe resistência estrutural e estabilidade face às acções verticais e horizontais, quer no seu plano, quer no plano perpendicular. A resistência às acções verticais depende da área de contacto entre os toros e da resistência à compressão perpendicular às fibras da madeira, enquanto as acções horizontais perpendiculares ao plano da parede serão suportadas pelas paredes transversais, dependendo a estabilidade das paredes a acções horizontais no seu plano do atrito desenvolvido nos entalhes que cada toro possui e da resistência oferecida pelas paredes ortogonais. Face à falta de conhecimento do comportamento destas construções em caso de ocorrência de um sismo, pretende-se, com o presente trabalho, avaliar numericamente o seu comportamento face à acção sísmica, recorrendo-se para tal a modelos simplificados. Estas análises baseiam-se nos resultados e conclusões de uma campanha de ensaios experimentais realizada previamente, com o objectivo de estudar o comportamento no plano das paredes comercializadas pela empresa Rusticasa, quando sujeitas a acções monotónicas e cíclicas., Timber as building material has held in the past a prominent importance. However, with the emergence of new materials such as steel and concrete, its structural use becomes limited. Exception to this trend happened in North and Central Europe, where the timber system "Log-house”, which involves the construction of walls by overlapping logs of circular or rectangular, usually having the faces upper and lower a notch in order to increase the surface contact and stability, was never abandoned. The walls that make up this building system give its structural strength and stability with respect to the vertical and horizontal actions, both in its plan and in the perpendicular. The resistance to vertical actions depends on the contact area between the logs and on the timber compressive strength perpendicular to grain. Horizontal loads perpendicular to the wall will be supported by the transverse walls while, the horizontal in-plane loads will be carried out by friction and by the resistance offered by the orthogonal walls. Given the lack of understanding of the behavior of the log-house system under earthquakes, this study aims to evaluate numerically its behavior under seismic actions. Such analysis will be based on the findings and conclusions achieved throughout monotonic and cyclic full-scale tests of timber log walls, performed previously, with the aim to have the European Technical Approval.
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.