22 results on '"Sensores de temperatura"'
Search Results
2. SISTEMA DE MONITORAMENTO AMBIENTAL E DE SEGURANÇA AGRÍCOLA BASEADO EM IoT.
- Author
-
Sarma, Priyanka, Islam, Atowar ul, and Bayan, Tony
- Subjects
- *
PLANT-water relationships , *SOIL degradation , *SOIL moisture , *WATER vapor , *WATER pumps - Abstract
Background: Agriculture is a vital part of the economy that feeds a part of the world expanding population. However, the sector faces several difficulties, including water constraints, soil degradation, and climate change. The demand for increased security and safety in agricultural activities worsens these problems. This paper suggests an IoT-based agriculture environment and security monitoring system address these issues. Aims: The main objective of this work is to develop an intelligent monitoring and automated irrigation system that minimizes water use based on individual conditions and enables real-time environmental Methods: The Arduino Uno R3 microcontroller based on Microchip ATmega328P is used to gather environmental data such as humidity, temperature, soil moisture levels. The Arduino board is integrated with a relay and RTC module to water plants at precise times. It also has a passive infrared sensor to detect intruders. ESP32 camera is also used to record the current condition of the agricultural ground automatically. A sample of reading in an interval of 1 hour is recorded. This method involves wirelessly transmitting the data to cloud-based platforms. Results: The value of the sensor at the start of a wet condition is 0. When this occurs, the motor pump turns off, and the measured value is communicated to the microcontroller through NodeMCU. The motor pump automatically turns ON and OFF when plants receive enough amount of water. Discussion: It has been observed the water pump starts as soon as the temperature threshold of 19.5 °C is achieved. It has been observed that as humidity increases, it is unnecessary to water the plants as the plants take up water vapor from the surface of the leaves under humid conditions. Conclusions: This research offers a convenient prototype model that can simultaneously measure temperature, moisture, and humidity, identify intrusion, and remotely monitor it over the internet. It was concluded that with the decrease in moisture of the soil, the plants need to be watered. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
3. A NEW METHOD FOR ANALYSING AND REPRESENTING GROUND TEMPERATURE VARIATIONS IN COLD ENVIRONMENTS. THE FUEGIAN ANDES, TIERRA DEL FUEGO, ARGENTINA.
- Author
-
OLIVEIRA, M., PÉREZ-ALBERTI, A., CRUJEIRAS, R. M., RODRÍGUEZ-CASAL, A., and CASTILLO-RODRÍGUEZ, F.
- Subjects
SEASONAL temperature variations ,EARTH temperature - Abstract
Copyright of Cuadernos de Investigación Geográfica is the property of Universidad de la Rioja, Servicio de Publicaciones and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
4. Comparação da temperatura do ar obtida por estação meteorológica convencional e automática Comparison of the air temperature obtained by conventional and automatic meteorological stations
- Author
-
André Samuel Strassburger, Antônio José Elias Amorim de Menezes, Tângela Denise Perleberg, Eberson Diedrich Eicholz, Marta Elena Gonzalez Mendez, and Edgar Ricardo Schöffel
- Subjects
sensores de temperatura ,temperatura média do ar ,temperaturas extremas ,termohigrógrafo ,temperature sensors ,average air temperature ,extreme temperature ,termo-hygrograph ,Meteorology. Climatology ,QC851-999 - Abstract
Este trabalho teve como objetivos comparar os dados da temperatura do ar (temperatura média e extrema), obtidos em uma Estação Meteorológica Convencional com os de uma Estação Meteorológica Automática, e avaliar as estimativas da temperatura média diária do ar por diferentes métodos. As estações meteorológicas estavam localizadas na Estação Agroclimatológica de Pelotas, Capão do Leão (31º52' S, 52º21' W e 13,2 m), Rio Grande do Sul, Brasil. A série de cada elemento foi obtida simultaneamente na Estação Automática e na Estação Convencional durante o período de 22/12/2005 a 21/12/2006. Existe alta equivalência para as medidas das temperaturas extremas e das estimativas das temperaturas médias entre as Estações Meteorológicas Convencional e Automática, independente do método utilizado para o cálculo da temperatura média do ar. O termohigrógrafo mede, com alta precisão, as temperaturas extremas do ar. Verificam-se pequenas diferenças nos horários de ocorrência das temperaturas mínimas e máximas entre as Estações Meteorológicas Convencional e Automática. A análise dos dados indica que a substituição da Estação Meteorológica Convencional pela Estação Meteorológicas Automática, na região Sul do Rio Grande do Sul, não acarreta mudanças significativas na série de dados de temperatura do ar.The objective of this work was to compare the air temperature data (average and extreme) obtained by a Conventional Meteorological Station and an Automatic Meteorological Station and evaluate different methods of estimating the average air temperature. The Meteorological Stations were located at the Agroclimatological Station of Pelotas, Capão do Leão (31º52' S, 52º21' W and 13,2 m), Rio Grande do Sul, Brazil. The data series were collected simultaneously in Conventional Meteorological Station and Automatic Meteorological Station during the period from 12/22/2005 to 12/21/2006. There is high equivalence in the measures of extreme temperature and average air temperature obtained from the Conventional and Automatic Meteorological Station, independently of the methods used for the calculation of average air temperature. The termo-hygrograph measures with high precision the extreme air temperature. There are small differences in the times of occurrence of the minimum and maximum temperatures between Conventional and Automatic Meteorological Stations. The data analysis indicated that the substitution of the Conventional Meteorological Station by Automatic Meteorological Station in Southern of Rio Grande do Sul does not changes significantly the air temperature data series.
- Published
- 2011
- Full Text
- View/download PDF
5. Avaliação de circuito eletrônico para medição de temperatura em instalações agrícolas por meio da porta paralela de um computador Evaluation of an electronic circuit for temperature measurement in agricultural buildings using the PC's parallel port
- Author
-
Antonio J. Steidle Neto and Sérgio Zolnier
- Subjects
sistemas de aquisição de dados ,sensores de temperatura ,instrumentação ,data acquisition systems ,temperature sensors ,instrumentation ,Agriculture (General) ,S1-972 - Abstract
Os sistemas de aquisição de dados de temperatura disponíveis comercialmente apresentam alto custo e grande complexidade operacional para a sua utilização em instalações agrícolas climatizadas. Este trabalho teve por objetivos propor, calibrar e validar um circuito eletrônico de baixo custo para a aquisição de dados de temperatura com base na freqüência de oscilação da tensão elétrica (0 a 5 V). O sensor empregado no circuito foi um termistor com resistência ômica de 10 kômega 25 ºC e coeficiente de temperatura negativo. O circuito eletrônico, conectado a um computador via porta paralela, foi calibrado por comparação com um termômetro-padrão de mercúrio em vidro. Após as medições, análises de regressão foram realizadas com os dados experimentais, gerando-se equações que relacionam freqüência com resistência e resistência com temperatura. Os coeficientes de determinação demonstraram excelentes correlações entre as variáveis (R² > 0,9999). Posteriormente, foram realizadas comparações entre as medições obtidas com o circuito eletrônico e dois sistemas convencionais de aquisição de dados. Os resultados demonstraram que o circuito proposto é capaz de medir com exatidão e precisão a temperatura na faixa de 10 a 40 ºC.The temperature data acquisition systems available commercially present high costs and operational complexity to be applied in environment controlled agricultural buildings. The objective of this work was to propose, calibrate and validate a low cost electronic circuit for measuring temperature based on the frequency of an alternating voltage (0 to 5 V). The sensor connected to the circuit was a thermistor with resistance of 10 komega 25 ºC and negative temperature coefficient. The electronic circuit was connected to a computer using the parallel port and calibration was performed by comparing the thermistor to a standard liquid-in-glass thermometer. Regression analyses were performed on experimental data to obtain equations relating the frequency variation to resistance and resistance to temperature. The coefficients of determination showed excellent correlation among the variables (R² > 0.9999). Comparisons of the measurements obtained with the electronic circuit and two conventional data acquisition systems were carried out. The results demonstrated that the proposed circuit is capable to measure temperatures from 10 to 40 ºC with precision and accuracy.
- Published
- 2006
- Full Text
- View/download PDF
6. Avaliação da transmissão de dados de temperatura no sistema 1-wireTM Evaluation of the temperature data transmission in the 1-wireTM system
- Author
-
Antonio J. Steidle Neto, Fernando C. Baêta, José H. Martins, Sérgio Zolnier, and Paulo M. B. Monteiro
- Subjects
sistemas de aquisição de dados ,sensores de temperatura ,instalações agrícolas ,data acquisition systems ,temperature sensors ,agricultural buildings ,Agriculture (General) ,S1-972 - Abstract
A necessidade de sistemas de monitoramento automático versáteis e de baixo custo que possam auxiliar o produtor agrícola na otimização dos processos produtivos, é evidente. Este trabalho foi realizado com o objetivo de pesquisar as limitações e as potencialidades de aplicação do sistema 1-wireTM na transmissão de dados de temperatura em instalações agrícolas. O sistema 1-wireTM é uma rede de transmissão de dados que possibilita a comunicação digital entre um computador e dispositivos da série 1-wireTM, tais como os sensores de temperatura DS1820. A transmissão de dados de temperatura nesse sistema foi avaliada em função do tipo dos condutores e do número de sensores DS1820. Com base nos resultados, concluiu-se que o aumento do número de sensores de temperatura DS1820 no sistema 1-wireTM incrementa a carga capacitiva de maneira distinta para cada um dos tipos de condutores estudados, podendo causar interrupções na transmissão de dados.The need of versatile and low cost automatic monitoring systems for the optimization of the agricultural productive processes is evident. This work was carried out to evaluate the limitations and potentialities of the 1-wireTM system for temperature data transmission in agricultural buildings. The 1-wireTM system is a data transmission network, which makes possible the digital communication between a computer and devices of the 1-wireTM series, such as the temperature DS1820 sensors. The temperature data transmission in this system was evaluated as a function of types of conductors and the number of DS1820 sensors. Based on the results, it was concluded that, by increasing the number of the DS1820 temperature sensors in the 1-wireTM system, the capacitive load increases in a different way for each conductor and can cause interruptions during temperature data transmission.
- Published
- 2005
- Full Text
- View/download PDF
7. Sensores digitais de temperatura com tecnologia one-wire: Um exemplo de aplicação didática na área de condução térmica.
- Author
-
do Amorim, Helio Salim, Dias, Marco Adriano, and Soares, Vitorvani
- Abstract
We present in this work a simple experiment of thermal conduction using digital temperature sensors with one-wire technology associated with an Arduino board to control and data acquisition. The sensors used are affordable and can be easily found in the country market. The experimental model reproduces a classic experiment of thermal conduction commonly used in textbooks of physics to present and discuss the Fourier law of heat conduction. The results were su?ciently sensitive to reveal a nonlinear temperature distribution in a situation where unrealistic boundary conditions, usually applied to the Fourier law in textbooks, results in linear behavior. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
8. Medição de temperatura: O saber comum ignorado nas aulas experimentais.
- Author
-
Vilar, A. B., de Jesus, V. L. B., de Matos, R. G., Marques, L. C. O., Zuim, F. A., de Souza, J. M., and Salgado, R. P.
- Abstract
Temperature measurements in undergraduate laboratories often do not take into account the dead time of the sensors and measurement systems, whether analogic or based on electronic data acquisition. This paper presents measurements and comparisons of different types of dead time thermometers, as well as some possibilities and strategies for adaptation and control of this limitation in experiments involving temperature measurements of liquids. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
9. Design of a low-power flash analog-to-digital converter chip for temperature sensors in 0.18 μm CMOS process.
- Author
-
Al., Al., Ibne Reaz, Mamun Bin, Jalil, Jubayer, Alauddin, Mohd, and Ali, Mohd
- Abstract
Copyright of Acta Scientiarum: Technology is the property of Universidade Estadual de Maringa and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2015
- Full Text
- View/download PDF
10. Diseño e implementación de sistemas de etiquetas pasivas basadas en líneas magneto-inductivas
- Author
-
Martínez Martínez, José Juan, Inclán Sánchez, Luis Fernando de, Herraiz Martínez, Francisco Javier, UC3M. Departamento de Teoría de la Señal y Comunicaciones, and Universidad Carlos III de Madrid. Departamento de Teoría de la Señal y Comunicaciones
- Subjects
Chipless passive tags ,RFID ,Telecomunicaciones ,Temperature sensors ,Electrónica ,Etiquetas pasivas sin chip ,Sensores de temperatura - Abstract
El objetivo de esta tesis es el diseño e implementación de un sistema de etiquetas pasivas sin chip. El sistema engloba tanto las propias etiquetas (cuyas aplicaciones van desde un sensor de temperatura hasta etiquetas RFID) como el sistema lector. En la actualidad, hay un gran interés en el desarrollo de etiquetas RFID y sensores sin chip ya que, a pesar de tener un alcance más corto y un número de bits o de información más limitado que sus análogos con chip, son una alternativa mucho más sencilla y barata para aplicaciones masivas y de bajo coste. En un primer lugar, se lleva a cabo el diseño de un sensor de temperatura en el dominio del tiempo basado en una línea de retardo MIW. El elemento periódico de la línea MIW usada es el denominado SSRR. Su funcionamiento se basa en el envío de un pulso en el dominio del tiempo cuya anchura es del orden de ns hacia la etiqueta, la cual está formada por una línea microstrip de acceso, la línea de retardo MIW y un reflector al final en el que se suelda un termistor. Cuando el pulso incidente llega al reflector, se refleja hacia el lector con una amplitud que varía en función de la temperatura, como lo hace la impedancia del termistor. La línea de retardo sirve para evitar el solapamiento entre el pulso incidente y el reflejado, consiguiéndose una lectura óptima de los pulsos. Tambien se diseñan etiquetas pasivas de RFID sin chip con esta tecnología. Estas etiquetas, que están basadas en SSRRs, codifican diferentes patrones dependiendo de la posición en donde se colocan los reflectores. Una vez queda comprobado el funcionamiento del sensor y de las etiquetas RFID, se llevan a cabo los diseños de dos sistemas de lectura, uno para medir el retardo en líneas MIW y otro que se usa como lector para el propio sensor de temperatura diseñado. Ambos sistemas de lectura están formados principalmente por dos bloques: el de generación y el de detección de señal, utilizándose una mezcla de elementos diseñados por el autor junto con dispositivos comerciales. Se llevan a cabo medidas del sensor de temperatura junto con el lector propuesto obteniéndose resultados satisfactorios. A partir de aquí, se realiza la sustitución del enlace cableado entre lector y etiquetas, que ha sido utilizado en los experimentos previos, por un enlace contactless. Para ello se diseñan dos sondas de lectura, una monopolar y la otra basada en propagación axial entre SSRRs, observándose un mejor funcionamiento al utilizar la segunda. De esta manera, se consigue decodificar dos etiquetas RFID que contienen los patrones 01 y 10 utilizando la sonda elegida. Tras llevar a cabo el experimento se obtuvieron resultados satisfactorios, al poder decodificar los patrones de ambas etiquetas. En conclusión, en esta tesis se consigue desarrollar y demostrar experimentalmente toda la parte de etiquetas pasivas (RFID y sensores de temperatura), el enlace inalámbrico de corto alcance con el lector y toda la electrónica de RF del mismo. The goal of this thesis is the design and implementation of a system based on chipless passive tags. The system includes both the tags (whose applications range from a temperature sensor to RFID tags) as well as the reader. Currently, there is a great interest in the development of chipless RFID tags and sensors. Although they have a shorter range and a more limited number of bits or information than the chipped ones, they are a much simpler and cheaper alternative for low-cost and massive applications. Firstly, the design of a temperature sensor in the time domain based on a MIW delay line is carried out. The periodic element of the MIW is the so-called SSRR. The operation systems is as follows: a pulse in time domain, whose width is in the order of ns is sent to the tag, which is formed by an microstrip line, the MIW delay line and a reflector at the end of the line with a thermistor welded on it. When the incident pulse reaches the reflector, it is backscattered towards the reader with an amplitude that varies depending on the temperature, as the impedance of the thermistor does. The delay line avoids the overlapping between the incident and the reflected pulse, obtaining an optimal reading of the pulses. Passive chipless RFID tags are also designed using this technology. The tags, which are based on SSRRs, encode different patterns depending on the position where the reflectors are placed. Once the good behavior of the sensor and RFID tags is verified, the designs of two reading systems are carried out. The first one is used to measure the delay introduce by MIW delay lines and the second one is used as a reader for the designed temperature sensor. Both reading systems consist mainly of two blocks: the signal generation and the signal detection blocks, in which a mix of elements designed by the author together with commercial devices is used. Measurements of the temperature sensor together with the proposed reader are carried out obtaining satisfactory results. In this point, the replacement of the wired link between the reader and the tags that has been used in the previous experiments by a contactless link is performed. Thus, two reading probes are designed, a monopolar probe and a SSRR-based probe, obtaining a better performance when using the second one. According to this, the decodification of two RFID tags that contains the 01 and 10 patterns using the proposed probe is carried out. Satisfactory results are obtained when the experiment is carried out, being able to decode the patterns encoded by both tags. In conclusion, the development and experimental demonstration of all the part of passive tags (RFID and temperature sensors), the shortrange wireless link with the reader and all the RF electronics is achieved in this thesis. Programa de Doctorado en Multimedia y Comunicaciones por la Universidad Carlos III de Madrid y la Universidad Rey Juan Carlos Presidente: Luis Fernando Herrán Ontañón.- Secretario: Carlos Rodríguez-Morcillo García.- Vocal: Gerard Zamora González
- Published
- 2019
11. A new method for analysing and representing ground temperature variations in cold environments. The Fuegian Andes, Tierra del Fuego, Argentina
- Author
-
Rosa M. Crujeiras-Casais, Francisco Castillo Rodríguez, Augusto Pérez Alberti, María Oliveira Pérez, Alberto Rodríguez Casal, Universidade de Santiago de Compostela. Departamento de Estatística, Análise Matemática e Optimización, and Universidade de Santiago de Compostela. Departamento de Xeografía
- Subjects
0106 biological sciences ,Circular data ,Datos circulares ,010504 meteorology & atmospheric sciences ,Philosophy ,Geography, Planning and Development ,Métodos paramétricos ,Environmental Science (miscellaneous) ,01 natural sciences ,Tierra ,Sensores de temperatura ,Diagrama de Taylor ,Active layer ,Capa activa ,Taylor diagram ,Ground temperature ,Earth and Planetary Sciences (miscellaneous) ,Non-parametric methods ,Temperature sensors ,Tierra del Fuego (Argentina) ,Humanities ,010606 plant biology & botany ,0105 earth and related environmental sciences - Abstract
The thermal response of soils in cold environments has been investigated in numerous studies. The data considered here were obtained in a study carried out in Tierra del Fuego, Argentina, as part of the IV International Polar Year. Temperature sensors were installed at ground level (0) and depths of -10, -20 and -60 cm in the study area, with the aim of characterizing the thermal response by detecting diurnal and annual variations. The study has two main aims. The first is to present and discuss the study findings regarding the thermal response of a soil in a sub-Antarctic environment by using classical descriptive analysis. The second, closely related, aim is to apply some novel statistical tools that would help improve this description. The study of freeze-thaw patterns can be approached from a non-parametric perspective, while taking into account the cyclical nature of the data. Data are considered cyclical when they can be represented on a unit circle, as with the hours in which certain events occur throughout a day (e.g. freezing and thawing). Analysis of this type of data is very different from the analysis of scalar data, as regards both descriptive and graphical measures. The application in this study of methods used to represent and analyse cyclical data improved visualization of the data and interpretation of the analytical findings. The main contribution of the present study is the use of estimators of the nuclear type density and derived techniques, such as the CircSiZer map, which enabled identification of significant freeze-thaw patterns. In addition, the relationships between the temperature recordings at different points were analysed using Taylor diagrams Los resultados de las investigaciones sobre la respuesta térmica del suelo en ambientes fríos han sido recogidos en un gran número de artículos. Las muestras de datos consideradas en este trabajo pertenecen también a un ambiente frío y se han obtenido de una investigación realizada en Tierra del Fuego, Argentina, bajo los auspicios del Año Polar Internacional. Con el fin de caracterizar la respuesta térmica, se instalaron diferentes sensores de temperatura a 0, -10, -20 y -60 cm de profundidad, permitiendo la detección de variaciones anuales y diarias. Este trabajo persigue un doble objetivo. Por un lado, la presentación de resultados y discusión sobre los mismos en relación al comportamiento térmico del suelo en un ambiente subantártico. Por otro lado, y apoyando al objetivo anterior, se introducen algunas herramientas estadísticas novedosas en este contexto, si bien el estudio se acompaña de análisis descriptivos clásicos. El estudio de patrones de congelación y descongelación puede enfocarse desde una perspectiva no paramétrica, a la vez que se tiene en cuenta la naturaleza circular (cíclica) de los datos. Una muestra de datos se considera circular cuando puede representarse sobre un círculo de radio unidad. Esto ocurre, por ejemplo, con las horas en las que suceden determinados eventos a lo largo de un día (por ejemplo, congelaciones y descongelaciones). El análisis de este tipo de datos es radicalmente distinto del que se realiza sobre datos escalares, tanto en lo que se refiere a medidas descriptivas como a métodos gráficos. El uso de representaciones y herramientas propias del análisis de datos circulares realizado en este trabajo permite una mejor visualización de los datos y de los resultados de su análisis. Como principal aportación, cabe destacar el uso de estimadores de la densidad tipo núcleo y técnicas derivadas, como el mapa CircSiZer, que identifica patrones significativos de congelación/descongelación. Además, el análisis de las relaciones entre registros de temperaturas en distintos puntos se presenta a través del uso de Diagramas de Taylor This research was funded by the Ministry of Education and Science (Spain) projects (POL2006-09071) as a contribution to the fourth International Polar Year. Research by M. Oliveira, R.M. Crujeiras and A. Rodríguez was partially supported by grants MTM2013-41383P and MTM2016-76929P awarded by the Ministry of Economy and Competitiveness and AEI/FEDER, Spain SI
- Published
- 2018
12. Soluções para instrumentação de um molde em ambiente industrial
- Author
-
Ferreira, Bruno Emílio Martins, Gonçalves, L. M., and Universidade do Minho
- Subjects
Instrumentation system ,Strain sensors ,Efficient mold ,Temperature sensors ,Engenharia Eletrotécnica, Eletrónica e Informática [Engenharia e Tecnologia] ,Moldes eficientes ,Sistema de instrumentação ,Sensores de temperatura ,Sensores de deformação ,Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática - Abstract
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores, O estado atual da economia, as constantes alterações dos valores da matéria-prima e o aumento da concorrência têm contribuído para o desgaste da rentabilidade dos fabricantes de peças de injeção. Uma das possíveis medidas para contrariar estes aspetos passa por reduzir os custos de produção através do desenvolvimento de moldes mais eficientes e de custo reduzido. Para assegurar um aumento do desempenho do molde é necessário haver uma evolução ao nível da incorporação do conhecimento tecnológico no molde. Ao serem incorporados sistemas avançados que permitem um controlo contínuo e em tempo real de determinados parâmetros do molde, possibilita que haja um aumento da eficiência do seu processo. Esta dissertação foca-se na implementação da instrumentação necessária para realizar a monitorização contínua das componentes responsáveis pelo controlo da temperatura e deformação do molde, assim como as condições ambientais em que este está inserido. A leitura da temperatura é feita com a utilização de um termopar e consequente circuito de leitura, enquanto que a deformação é medida utilizando um extensómetro ligado a uma configuração de ponte de Wheatstone de quatro ramos ativos. A resposta dos sensores utilizados foi testada individualmente de forma a verificar o seu comportamento nas várias situações a que o molde é submetido. Do trabalho desenvolvido resultou um protótipo do sistema de instrumentação que permite viabilizar a abordagem proposta, mas com um custo mais reduzido que as outras abordagens existentes no mercado., The current state of the economy, the constant changes of the feedstock and the increase of the competition has contributed to the wear and tear of the profitability of the injection parts manufacturers. One of the possible ways to contradict these aspects is to reduce the costs of production through the development of more efficient and cost-effective molds. To ensure an increase in mold performance it’s necessary to have an improvement regarding the incorporation of technological knowledge in the mold. The incorporation of advanced systems, which allows continuous and real time monitoring of certain parameters, enables increased efficiency of its process. This dissertation focuses on the implementation of the necessary instrumentation to perform the continuous monitoring of the components responsible for temperature and strain control in the mold, and the environmental conditions in which it is inserted. The measurement of temperature data is made with the use of a thermocouple and consequent reading circuit, while the strain is measure with a strain gage connected to a Wheatstone bridge with four active branches. The response of the used sensors was tested individually to verify their behaviour in the various situations to which the mold is submitted. The developed work resulted in a prototype of the instrumentation system that allows the proposed approach to be feasible, but at a lower cost than the other approaches in the market.
- Published
- 2017
13. Metodología para la gestión dinámica de la capacidad en líneas aéreas de alta tensión basada en múltiples medidas discretas de condiciones ambientales
- Author
-
Martínez Torre, Raquel, Mañana Canteli, Mario, and Universidad de Cantabria
- Subjects
Ampacidad ,Energías renovables ,Integration ,Weather stations ,Redes neuronales ,Weather conditions ,Energía eólica ,Power systems ,Estaciones meteorológicas ,Overhead lines ,Predicción ,Temperature sensors ,Wind energy ,Sistemas de potencia ,Renewable energies ,Dynamic management ,Sensores de temperatura ,CIGRÉ ,Gestión dinámica ,Condiciones ambientales ,IEEE ,Planning ,Ampacity ,Integración ,Planificación ,Líneas aéreas ,Neural networks ,Forecasting - Abstract
RESUMEN: Esta tesis desarrolla una metodología para la mejora en la implantación de sistemas de gestión dinámica de las líneas aéreas de alta tensión en tiempo real y a corto plazo basada en la medida puntual de las condiciones ambientales. Los sistemas actuales cuentan con debilidades que hacen complicada e ineficiente la operación basada en la gestión dinámica. Esta tesis trata de reforzar esas debilidades. En primer lugar, se crea una metodología para el emplazamiento más adecuado de los sensores necesarios para la gestión dinámica. A continuación, se estudian las desviaciones en los cálculos de la capacidad de los conductores creando procedimientos de optimización de los cálculos. Por último, y debido a la gran necesidad de planificar la gestión dinámica a corto plazo, se plantea un sistema de predicción de las variables meteorológicas y de predicción directa de la capacidad de las líneas. Todos los procedimientos se aplicarán a una línea de alta tensión existente. ABSTRACT: This Thesis develops a methodology to improve the implementation of dynamic management systems of overhead transmission lines in real time and in the short term. This methodology are based on multiple measures of environmental conditions. Current systems have weaknesses that complicate and make inefficient the dynamic exploitation. The aim of this Thesis is to address existing weaknesses. Firstly, a methodology to achieve a suitable location of the sensors is created. In a further step, deviations in calculations of capacity of the conductors are studied to obtain procedures for the optimization of the calculations. Finally, due to the great need to plan the dynamic management in the short time, a forecasting system of environmental conditions and of direct capacity of the lines is raised. The different procedures are applied to a real case line.
- Published
- 2016
14. Medição de temperatura: O saber comum ignorado nas aulas experimentais
- Author
-
Vilar, A.B., Jesus, V.L.B. de, Matos, R.G. de, Marques, L.C.O., Zuim, F.A., Souza, J.M. de, and Salgado, R.P.
- Subjects
sensores de temperatura ,tempo morto ,scientific instrumentation ,Arduino ,instrumentação científica ,temperature sensors ,dead time - Abstract
As medições de temperatura em laboratórios didáticos frequentemente não levam em consideração o tempo morto dos sensores e dos sistemas de medição, sejam esses analógicos ou baseados na aquisição eletrônica de dados. Neste artigo são apresentadas medidas e comparações do tempo morto de diferentes tipos de termômetros, bem como algumas possibilidades e estratégias para a adaptação e controle dessa limitação em experimentos que envolvam medidas de temperatura de líquidos. Temperature measurements in undergraduate laboratories often do not take into account the dead time of the sensors and measurement systems, whether analogic or based on electronic data acquisition. This paper presents measurements and comparisons of different types of dead time thermometers, as well as some possibilities and strategies for adaptation and control of this limitation in experiments involving temperature measurements of liquids.
- Published
- 2015
15. OBTENÇÃO DE COMPOSIÇÕES CERÂMICAS Mn-Ni-Co VIA SÍNTESE POR LIOFILIZAÇÃO E SUA CARACTERIZAÇÃO ELÉTRICA COMO SENSOR DE TEMPERATURA
- Author
-
Silva, Edson José Lima da, Pianaro, Sidnei Antonio, Pukasiewicz, Anderson Geraldo Marenda, and Zara, Alfredo José
- Subjects
sensores de temperatura ,manganese oxides Nickel and Cobalt ,freeze drying ,Liofilização, óxidos de Mangânes Niquel e Cobalto ,temperature sensors ,liofilization ,ENGENHARIAS::ENGENHARIA DE MATERIAIS E METALURGICA [CNPQ] - Abstract
Made available in DSpace on 2017-07-21T20:42:36Z (GMT). No. of bitstreams: 1 EDSON JOSE LIMA DA SILVA.pdf: 3364047 bytes, checksum: 8d0d1391435837a4f603477a06c59876 (MD5) Previous issue date: 2011-12-22 This work describes the preparation of nanoparticles of spinel structure, made from oxides of Manganese, Nickel and Cobalt, via lyophilization process, which was compared to the process of obtaining conventional mixture of oxides, in order to analyze different forms of preparation and its influence on electrical properties (characteristic resistance, temperature coefficient, stability of the thermistor), through the measures obtained by applying a voltage of 5 volts on pads and subjecting them to a temperature range of 20 C to 300 C, measured with a thermocouple type K The microstructures were analyzed by scanning electron microscopy (SEM), the average particle size ranged from 60 to 93 nm. X-ray spectroscopy to determine the phases present in the samples and analysis of infrared to identify in the process, organic waste and the organic phase transitions were completely volatilized during the controlled heating pad on high-temperature furnace (with resistance molybdenum silicide) (Lindenberg). Through the obtained results it was noted a certain advantage at all temperatures of the samples had the composition Ni Mn and Co on the Mn Ni which had only giving larger values between 4335 and 4571 for samples made from the process liofilization. Este trabalho descreve a preparação de nanoparticulas de estrutura espinélio, feitas a partir de óxidos de Manganês, Níquel e Cobalto, via processo de liofilização, o qual foi comparado ao processo de obtenção convencional, mistura de óxidos, afim de se analisar diferentes formas de preparação e sua influência nas propriedades elétricas (resistência característica, coeficiente de temperatura, estabilidade do termistor), através das medidas obtidas aplicando-se uma tensão de 5 volts nas pastilhas e submetendo-as a uma variação de temperatura de 20C a 300C, aferidos com um termopar tipo K. As Microestruturas foram analisadas por microscopia eletrônica de varredura (MEV), o tamanho médio das partículas ficaram entre 60 a 93 nm. Espectroscopia de raios X para determinação das fases presentes nas amostras e análise de infravermelho para se identificar em que fase do processo os resíduos orgânicos e as transições de fases orgânicas foram totalmente volatilizados ao longo do aquecimento controlado das pastilhas em forno de alta temperatura (com resistência de siliceto de molibdênio) (Lindenberg). Através dos resultados obtidos notou-se uma certa vantagem em todas as temperaturas das amostras que tinham na composição Mn Ni e Co sobre as que tinham apenas Mn Ni dando valores de maiores, entre 4335 e 4571 para as amostras feitas a partir do processo de liofilização.
- Published
- 2011
16. Control of the flame front advance in a sintering bed of iron ores
- Author
-
Javier Mochón, Roberto Parra, Íñigo Ruiz-Bustinza, and Alejandro Cores
- Subjects
lcsh:TN1-997 ,Data acquisition system ,Materials science ,Mineralogy ,Sintering ,Combustion ,Combustión ,Thermocouple ,Sinterización ,Minerales de hierro ,Sistema de adquisición de datos ,Materials Chemistry ,Exit point ,Temperature sensors ,Physical and Theoretical Chemistry ,Flame front ,Iron ores ,lcsh:Mining engineering. Metallurgy ,Maximum temperature ,Mining engineering. Metallurgy ,TN1-997 ,Metals and Alloys ,Coke ,Frente de llama ,Condensed Matter Physics ,Sensores de temperatura ,Pilot plant ,Ajuste de algoritmos ,Algorithmic adjustments - Abstract
11 páginas, 15 figuras, 4 tablas., [EN] A sintering pan of 40 cm cubed is loaded with a mixture of iron ores, limestone and coke weighing 110 kg in a sintering pilot plant. In this sintering pan, a series of thermocouples have been introduced at different depths. Tests have been carried out to study the width of the combustion zone and the maximum temperature of the flame front across the sintering bed. For the analysis of the results, a data acquisition system was used. This consisted of two modules connected in serie, for performing the analogue-digital conversion. The analogue entry point is the exit point of the thermocouples and the digital exit point was the temperature average. A computer was used for conserving and storing the data and for carrying out interpolations, simulating the state and evolution of the flame front across the bed., [ES] En una planta piloto de sinterización se cargan, en la paila cúbica de 40 cm de lado, 110 kg de una mezcla de minerales de hierro, caliza y coque, donde se han introducido una serie de termopares a diferentes profundidades. Se realizan ensayos para estudiar la evolución del ancho de la zona de combustión y de la temperatura máxima del frente de llama a través del lecho de sinterización. Para el análisis de los resultados se utiliza un sistema de adquisición de datos formado por dos módulos conectados en serie, encargados de realizar la conversión analógico-digital. La entrada analógica es la salida de los termopares y la salida digital es la medida de la temperatura. Se dispone de un ordenador para la conservación y almacenamiento de los datos y para realizar interpolaciones que simulan el estado y evolución del frente de llama a través del lecho.
- Published
- 2010
17. Caracterização da sensibilidade de fibras de cristal fotônico à pressão e temperatura para aplicações em sensoriamento
- Author
-
Oliveira, Rafael Euzebio Pereira de and Matos, Christiano José Santiago de
- Subjects
sensores de temperatura ,microstructured fibers ,photonic crystal fibers ,sensores a fibra óptica ,optical fiber sensing ,fibras de cristal fotônico ,pressure sensors ,sensores de pressão ,ENGENHARIAS::ENGENHARIA ELETRICA [CNPQ] ,temperature sensors ,fibras micro-estruturadas - Abstract
In this dissertation the transmission properties of photonic crystal fibers are assessed under the influence of pressure and temperature for sensing applications. A review is given of the light propagation in conventional optical fibers and the effects of pressure and temperature on the refractive index of silica are studied. Photonic crystals in 1 and 2 dimensions are also studied. Then, microstructured fibers and photonic crystal fibers are addressed and their guidance properties and general applications are shown. A review is made of temperature and pressure sensors based on conventional fibers, Bragg gratings and microstructured and photonic crystal fibers described in the literature. Finally, results are shown and discussed of the experiments with the application of pressure on a hollow-core photonic crystal fiber, for which high-order bandgaps, in the visible spectral region, were identified and characterized for the first time. These bandgaps are shown to be pressure sensitive. Applying external hydrostatic pressure over the fiber, optical transmission variations of a few dB were observed for pressures of hundreds of kgf/cm², while when the fiber holes were internally pressurized a similar variation was achieved for units of kgf/cm². The response of light polarization, and hence of the fiber birefringence, to internal pressure was also analyzed.. In the other part of the experimental work, the temperature-induced bandgap spectral shift of photonic bandgap fibers was characterized. The response of a hollow-core fiber, a hybrid fiber and an all-solid fiber was characterized with bandgap shifts of up to 36 pm/°C in straight fibers. For the all-solid fiber the influence of bending over the bandgaps was characterized, as well as temperature-induced bandgaps shifts under these conditions. For a straight fiber, a simple model for the bandgap shift calculation is presented and showed good agreement with the experimental results. Closing the work, the conclusions are presented. Nessa dissertação são avaliadas as propriedades de transmissão em fibras de cristal fotônico sob influência da pressão e da temperatura visando aplicações em sensoriamento. Antes é feita uma revisão da propagação da luz em fibras ópticas convencionais e os efeitos da pressão e temperatura sobre o índice de refração da sílica. Também são estudados os cristais fotônicos em 1 e 2 dimensões. Em seguida são estudadas as fibras microestruturadas e de cristal fotônico e são mostradas suas propriedades de guiamento e aplicações gerais. Em seguida é mostrada uma revisão sobre sensores de temperatura e pressão utilizando fibras convencionais, redes de Bragg e fibras de cristal fotônico. Finalmente são mostrados e discutidos os resultados dos experimentos com pressão em uma fibra de cristal fotônico de núcleo oco, para a qual foram identificados, caracterizados e reportados pela primeira vez bandgaps de ordem superior localizados na região visível do espectro, que são sensíveis à pressão. Aplicando-se pressão hidrostática na parte externa da fibra obteve-se variação de alguns dB na transmissão óptica para pressões de centenas de kgf/cm², enquanto que quando a pressão era aplicada no interior dos buracos da fibra obteve-se variação semelhante para unidades de kgf/cm². Também foi analisada a resposta da polarização da luz guiada, e portanto da birrefringência da fibra, à pressão interna. Em outra parte do trabalho experimental foi caracterizada a resposta à temperatura do deslocamento espectral dos bandgaps em fibras de bandgap fotônico. Foram caracterizadas as respostas de uma fibra de núcleo oco, uma fibra híbrida e uma fibra totalmente sólida com deslocamentos de até 36 pm/°C para fibras esticadas. Para a fibra totalmente sólida foi também caracterizada a influência da curvatura da fibra sobre os bandgaps e como o deslocamento devido à temperatura é afetado nessas condições. Para uma fibra esticada é apresentado um modelo para o cálculo aproximado do deslocamento dos bandgaps em função da temperatura obtendo-se resultados satisfatórios com o experimento. Na ultima parte do trabalho são apresentadas as conclusões finais.
- Published
- 2010
18. Control del avance del frente de llama en el lecho de sinterización de minerales de hierro
- Author
-
Cores, A., Mochón, J., Ruiz-Bustinza, I., and Parra, R.
- Subjects
Data acquisition system ,Combustion ,Frente de llama ,Combustión ,Sensores de temperatura ,Sintering ,Sinterización ,Minerales de hierro ,Sistema de adquisición de datos ,Temperature sensors ,Ajuste de algoritmos ,Iron ores ,Algorithmic adjustments ,Flame front - Abstract
A sintering pan of 40 cm cubed is loaded with a mixture of iron ores, limestone and coke weighing 110 kg in a sintering pilot plant. In this sintering pan, a series of thermocouples have been introduced at different depths. Tests have been carried out to study the width of the combustion zone and the maximum temperature of the flame front across the sintering bed. For the analysis of the results, a data acquisition system was used. This consisted of two modules connected in serie, for performing the analogue-digital conversion. The analogue entry point is the exit point of the thermocouples and the digital exit point was the temperature average. A computer was used for conserving and storing the data and for carrying out interpolations, simulating the state and evolution of the flame front across the bed. En una planta piloto de sinterización se cargan, en la paila cúbica de 40 cm de lado, 110 kg de una mezcla de minerales de hierro, caliza y coque, donde se han introducido una serie de termopares a diferentes profundidades. Se realizan ensayos para estudiar la evolución del ancho de la zona de combustión y de la temperatura máxima del frente de llama a través del lecho de sinterización. Para el análisis de los resultados se utiliza un sistema de adquisición de datos formado por dos módulos conectados en serie, encargados de realizar la conversión analógico-digital. La entrada analógica es la salida de los termopares y la salida digital es la medida de la temperatura. Se dispone de un ordenador para la conservación y almacenamiento de los datos y para realizar interpolaciones que simulan el estado y evolución del frente de llama a través del lecho.
- Published
- 2010
- Full Text
- View/download PDF
19. Avaliação de circuito eletrônico para medição de temperatura em instalações agrícolas por meio da porta paralela de um computador
- Author
-
Sérgio Zolnier and Antonio José Steidle Neto
- Subjects
Accuracy and precision ,Engineering ,sensores de temperatura ,business.industry ,Data acquisition systems ,Thermistor ,Electrical engineering ,sistemas de aquisição de dados ,Agricultural and Biological Sciences (miscellaneous) ,Temperature measurement ,Data acquisition ,Thermometer ,Calibration ,Temperature sensors ,business ,Temperature coefficient ,Instrumentation ,instrumentação ,Electronic circuit - Abstract
Os sistemas de aquisição de dados de temperatura disponíveis comercialmente apresentam alto custo e grande complexidade operacional para a sua utilização em instalações agrícolas climatizadas. Este trabalho teve por objetivos propor, calibrar e validar um circuito eletrônico de baixo custo para a aquisição de dados de temperatura com base na freqüência de oscilação da tensão elétrica (0 a 5 V). O sensor empregado no circuito foi um termistor com resistência ômica de 10 kômega 25 ºC e coeficiente de temperatura negativo. O circuito eletrônico, conectado a um computador via porta paralela, foi calibrado por comparação com um termômetro-padrão de mercúrio em vidro. Após as medições, análises de regressão foram realizadas com os dados experimentais, gerando-se equações que relacionam freqüência com resistência e resistência com temperatura. Os coeficientes de determinação demonstraram excelentes correlações entre as variáveis (R² > 0,9999). Posteriormente, foram realizadas comparações entre as medições obtidas com o circuito eletrônico e dois sistemas convencionais de aquisição de dados. Os resultados demonstraram que o circuito proposto é capaz de medir com exatidão e precisão a temperatura na faixa de 10 a 40 ºC. The temperature data acquisition systems available commercially present high costs and operational complexity to be applied in environment controlled agricultural buildings. The objective of this work was to propose, calibrate and validate a low cost electronic circuit for measuring temperature based on the frequency of an alternating voltage (0 to 5 V). The sensor connected to the circuit was a thermistor with resistance of 10 komega 25 ºC and negative temperature coefficient. The electronic circuit was connected to a computer using the parallel port and calibration was performed by comparing the thermistor to a standard liquid-in-glass thermometer. Regression analyses were performed on experimental data to obtain equations relating the frequency variation to resistance and resistance to temperature. The coefficients of determination showed excellent correlation among the variables (R² > 0.9999). Comparisons of the measurements obtained with the electronic circuit and two conventional data acquisition systems were carried out. The results demonstrated that the proposed circuit is capable to measure temperatures from 10 to 40 ºC with precision and accuracy.
- Published
- 2006
20. Evaluation of the temperature data transmission in the 1-wireTM system
- Author
-
Paulo Marcos de Barros Monteiro, José Helvecio Martins, Fernando da Costa Baêta, Antonio José Steidle Neto, and Sérgio Zolnier
- Subjects
sensores de temperatura ,Agricultural buildings ,Data acquisition systems ,instalações agrícolas ,Temperature sensors ,sistemas de aquisição de dados ,Agricultural and Biological Sciences (miscellaneous) - Abstract
A necessidade de sistemas de monitoramento automático versáteis e de baixo custo que possam auxiliar o produtor agrícola na otimização dos processos produtivos, é evidente. Este trabalho foi realizado com o objetivo de pesquisar as limitações e as potencialidades de aplicação do sistema 1- wire TM na transmissão de dados de temperatura em instalações agrícolas. O sistema 1-wire TM é uma rede de transmissão de dados que possibilita a comunicação digital entre um computador e dispositivos da série 1-wire TM , tais como os sensores de temperatura DS1820. A transmissão de dados de temperatura nesse sistema foi avaliada em função do tipo dos condutores e do número de sensores DS1820. Com base nos resultados, concluiu-se que o aumento do número de sensores de temperatura DS1820 no sistema 1-wire TM incrementa a carga capacitiva de maneira distinta para cada um dos tipos de condutores estudados, podendo causar interrupções na transmissão de dados. The need of versatile and low cost automatic monitoring systems for the optimization of the agricultural productive processes is evident. This work was carried out to evaluate the limitations and potentialities of the 1-wire TM system for temperature data transmission in agricultural buildings. The 1-wire TM system is a data transmission network, which makes possible the digital communication between a computer and devices of the 1-wire TM series, such as the temperature DS1820 sensors. The temperature data transmission in this system was evaluated as a function of types of conductors and the number of DS1820 sensors. Based on the results, it was concluded that, by increasing the number of the DS1820 temperature sensors in the 1-wire TM system, the capacitive load increases in a different way for each conductor and can cause interruptions during temperature data transmission.
- Published
- 2005
21. Logic for consistent annotation: application in data acquisition of temperature sensors
- Author
-
LIMA JÚNIOR, Luis Hermano Casado de, FREIRE, Raimundo Carlos Silvério., MELO, Hiran de., and ASSIS, Francisco Marcos de.
- Subjects
Aquisição de dados ,Sensores de temperatura ,Paraconsistory logic ,Temperature sensors ,Data acquisition ,Engenharia Elértrica ,Lógica paraconsistente - Abstract
Submitted by Deyse Queiroz (deysequeirozz@hotmail.com) on 2019-01-30T10:45:15Z No. of bitstreams: 1 LUIS HERMANO CASADO DE LIMA JUNIOR - DISSERTAÇÃO PPGEE 2003..pdf: 27835414 bytes, checksum: 578f22b7176fabb7138de32290e52bb3 (MD5) Made available in DSpace on 2019-01-30T10:45:15Z (GMT). No. of bitstreams: 1 LUIS HERMANO CASADO DE LIMA JUNIOR - DISSERTAÇÃO PPGEE 2003..pdf: 27835414 bytes, checksum: 578f22b7176fabb7138de32290e52bb3 (MD5) Previous issue date: 2003-12 Nesta dissertação são apresentados os resultados de uma investigação da utilização da Lógica Paraconsistente anotada na medição e monitoramento da temperatura de um líquido aquecido por uma fonte de calor controlada. Na lógica paraconsistente anotada é necessário que se tenha à compreensão de como as imprecisões e incertezas ocorrem no processo de medição utilizando-se a instrumentação eletrônica, possibilitando a aferição da relevância e confiabilidade dos resultados obtidos através da aplicação da teoria da lógica paraconsistente. A característica fundamental da lógica paraconsistente é a de representar o manuseio de informações imprecisas, provendo um método de traduzir expressões verbais, vagas, imprecisas e qualitativas em valores numéricos. Apresenta-se um sistema projetado para a medição e o monitoramento da temperatura de um líquido no qual um microcontrolador é programado utilizando a lógica paraconsistente anotada de dois valores. Na medição da temperatura de um líquido utilizam-se dois pares de sensores que são distribuídos de modo a ressaltar as inconsistências das medidas. No monitoramento os sinais gerados pelos sensores, depois de processados por um conversor A/D, são analisados por meio de um algoritmo baseado na Lógica Paraconsistente. O controle da fonte de calor é efetuado por um sinal proveniente do microcontrolador após uma conversão D/A. Nos experimentos observou-se que os resultados das medidas de temperatura apresentavam uma exatidão de + I o C. In this dissertation are presented of the results of an investigation of the use the noted paraconsistente logic in the measurement and monitorization of the temperature of a warm liquid for a heat source. In the noted paraconsitente logic is necessary the comprehension of how the imprecision and uncertain occur in the measurement process use the electronic instrumentation, enabling of the relevance and reliance gauge of the results gathered through paraconsistente logic theory. The fundamental characteristic of the paraconsistente logic is its ability to represent the handling of inexact information, providing a method of translating verbal expressions, vacancies, imprecise and qualitative in numeric values. It is presented a projected system for the measurement and the monitorization of the temperature of a liquid in which a microtroller is programmed using the noted paraconsistente logic of two values. In the measurement of the temperature of a liquid was used two pairs or temperature sensors distributed from way to emphasize the inconsistencies of the measures. In the monitorization the sings generated by the temperature sensors, after having processed for a converter A/D are analyzed through an algorithm based on the paraconsistente logic. The control of heat source is made by an sign originating from the microcontroller after a conversion D/A. In the experiments it was observed that the results of the temperature measures presented an accuracy of + 1 °C.
- Published
- 2003
22. (Digital sensors of temperature with one-wire technology: An example of pedagogical application in the area of thermal conduction)
- Author
-
Helio Salim do Amorim, Marco Adriano Dias, and V. Soares
- Subjects
Physics ,condução térmica ,sensores de temperatura ,General Physics and Astronomy ,Arduino ,heat conduction ,Humanities ,temperature sensors ,lcsh:Physics ,lcsh:QC1-999 ,Education - Abstract
Neste trabalho apresentamos uma experiência simples de condução térmica usando sensores de temperatura digitais com tecnologia one-wire(um-fio) associados a uma placa Arduino para controle e aquisição de dados. Os sensores utilizados são acessóveis e podem ser facilmente encontrados no mercado nacional. O modelo experimental reproduz uma experiência clássica de condução térmica usada comumente em livros didáticos de física para apresentar e discutir a lei de Fourier da condução térmica. Os resultados se mostraram suficientemente sensíveis para revelar uma distribuição não linear de temperaturas numa situação em que condições de contorno pouco realistas, e comumente aplicadas à lei de Fourier nos livros didáticos, resulta num comportamento linear. We present in this work a simple experiment of thermal conduction using digital temperature sensors with one-wire technology associated with an Arduino board to control and data acquisition. The sensors used are affordable and can be easily found in the country market. The experimental model reproduces a classic experiment of thermal conduction commonly used in textbooks of physics to present and discuss the Fourier law of heat conduction. The results were sufficiently sensitive to reveal a nonlinear temperature distribution in a situation where unrealistic boundary conditions, usually applied to the Fourier law in textbooks, results in linear behavior.
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.