1. Validation of the photon dose calculation model in the VARSKIN 4 skin dose computer code.
- Author
-
Sherbini S, Decicco J, Struckmeyer R, Saba M, and Bush-Goddard S
- Subjects
- Reproducibility of Results, Models, Biological, Monte Carlo Method, Photons, Radiation Dosage, Skin radiation effects
- Abstract
An updated version of the skin dose computer code VARSKIN, namely VARSKIN 4, was examined to determine the accuracy of the photon model in calculating dose rates with different combinations of source geometry and radionuclides. The reference data for this validation were obtained by means of Monte Carlo transport calculations using MCNP5. The geometries tested included the zero volume sources point and disc, as well as the volume sources sphere and cylinder. Three geometries were tested using source directly on the skin, source off the skin with an absorber material between source and skin, and source off the skin with only an air gap between source and skin. The results of these calculations showed that the non-volume sources produced dose rates that were in very good agreement with the Monte Carlo calculations, but the volume sources resulted in overestimates of the dose rates compared with the Monte Carlo results by factors that ranged up to about 2.5. The results for the air gap showed poor agreement with Monte Carlo for all source geometries, with the dose rates overestimated in all cases. The conclusion was that, for situations where the beta dose is dominant, these results are of little significance because the photon dose in such cases is generally a very small fraction of the total dose. For situations in which the photon dose is dominant, use of the point or disc geometries should be adequate in most cases except those in which the dose approaches or exceeds an applicable limit. Such situations will often require a more accurate dose assessment and may require the use of methods such as Monte Carlo transport calculations.
- Published
- 2012
- Full Text
- View/download PDF