1. 3-dimensionally printed patient-specific glenoid drill guides vs. standard nonspecific instrumentation: a randomized controlled trial comparing the accuracy of glenoid component placement in anatomic total shoulder arthroplasty.
- Author
-
Dasari SP, Menendez ME, Espinoza Orias A, Khan ZA, Vadhera AS, Ebersole JW, White GM, Forsythe B, Cole BJ, Nicholson GP, Garrigues GE, and Verma NN
- Subjects
- Humans, Scapula surgery, Arthroplasty, Tomography, X-Ray Computed, Imaging, Three-Dimensional methods, Arthroplasty, Replacement, Shoulder methods, Shoulder Joint diagnostic imaging, Shoulder Joint surgery, Glenoid Cavity diagnostic imaging, Glenoid Cavity surgery
- Abstract
Background: Traditional, commercially sourced patient-specific instrumentation (PSI) systems for shoulder arthroplasty improve glenoid component placement but can involve considerable cost and outsourcing delays. The purpose of this randomized controlled trial was to compare the accuracy of glenoid component positioning in anatomic total shoulder arthroplasty (aTSA) using an in-house, point-of-care, 3-dimensionally (3D) printed patient-specific glenoid drill guide vs. standard nonspecific instrumentation., Methods: This single-center randomized controlled trial included 36 adult patients undergoing primary aTSA. Patients were blinded and randomized 1:1 to either the PSI or the standard aTSA guide groups. The primary endpoint was the accuracy of glenoid component placement (version and inclination), which was determined using a metal-suppression computed tomography scan taken between 6 weeks and 1 year postoperatively. Deviation from the preoperative 3D templating plan was calculated for each patient. Blinded postoperative computed tomography measurements were performed by a fellowship-trained shoulder surgeon and a musculoskeletal radiologist., Results: Nineteen patients were randomized to the patient-specific glenoid drill guide group, and 17 patients were allocated to the standard instrumentation control group. There were no significant differences between the 2 groups for native version (P = .527) or inclination (P = .415). The version correction was similar between the 2 groups (P = .551), and the PSI group was significantly more accurate when correcting version than the control group (P = .042). The PSI group required a significantly greater inclination correction than the control group (P = .002); however, the 2 groups still had similar accuracy when correcting inclination (P = .851). For the PSI group, there was no correlation between the accuracy of component placement and native version, native inclination, or the Walch classification of glenoid wear (P > .05). For the control group, accuracy when correcting version was inversely correlated with native version (P = .033), but accuracy was not correlated with native inclination or the Walch classification of glenoid wear (P > .05). The intraclass correlation coefficient was 0.703 and 0.848 when measuring version and inclination accuracy, respectively., Conclusion: When compared with standard instrumentation, the use of in-house, 3D printed, patient-specific glenoid drill guides during aTSA led to more accurate glenoid component version correction and similarly accurate inclination correction. Additional research should examine the influence of proper component position and use of PSI on clinical outcomes., (Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024