1. Focusing aerogel RICH optimization
- Author
-
Barnyakov, A.Yu., Barnyakov, M.Yu., Bobrovnikov, V.S., Buzykaev, A.R., Danilyuk, A.F., Gulevich, V.V., Kirillov, V.L., Kononov, S.A., Kravchenko, E.A., Onuchin, A.P., and Porosev, V.V.
- Subjects
- *
DETECTORS , *ELECTRONS , *HADRONS , *PHYSICS instruments - Abstract
Abstract: The method of improvement of Cherenkov angle resolution in RICH detectors using ‘focusing’ aerogel radiators (FARICH) is under investigation. The ‘focusing’ three-layer aerogel radiator was investigated using a digital radiographic device. The Monte Carlo calculations of velocity resolution based on measured variations of the refractive index in aerogel tile are presented. With the observed variations, - and K-mesons can be separated up to 8.4GeV/c, - and -mesons can be separated up to . We studied the use of sodium fluoride radiator in a RICH detector. NaF radiator extends the working momentum region for the identification down to 0.6GeV/c. It has been shown that a RICH detector with NaF radiator can achieve a competitive velocity resolution up to 5GeV/c as compared to single-layer aerogel RICH. [Copyright &y& Elsevier]
- Published
- 2008
- Full Text
- View/download PDF