1. Comparison of left ventricular lead upgrade vs continued medical care among patients eligible for cardiac resynchronization therapy at the time of defibrillator generator replacement: Predictors of left ventricular lead upgrade and associations with long-term outcomes.
- Author
-
Hyman MC, Bao H, Curtis JP, Minges K, Schaller RD, Birgersdotter-Green U, Marchlinski FE, and Hsu JC
- Subjects
- Aged, Female, Follow-Up Studies, Heart Failure physiopathology, Humans, Male, Retrospective Studies, Treatment Outcome, Cardiac Resynchronization Therapy methods, Defibrillators, Implantable, Heart Failure therapy, Heart Ventricles physiopathology, Registries
- Abstract
Background: Randomized trials evaluating cardiac resynchronization therapy (CRT) have excluded patients with a pre-existing implantable cardioverter-defibrillator (ICD). The association of CRT upgrade with clinical outcomes in patients with a pre-existing ICD is unclear., Objective: The purpose of this study was to examine a CRT-eligible population to evaluate clinical outcomes associated with CRT upgrade compared to patients who did not undergo CRT., Methods: Using the National Cardiovascular Data Registry (NCDR) ICD Registry between April 2010 and December 2014, we created a hierarchical logistic regression model to identify predictors of CRT upgrade in a CRT-eligible ICD population. In the subpopulation of patients with Medicare-linked claims data, differential outcomes were determined with censoring at 3 years. The primary endpoint of this study was all-cause mortality, with secondary endpoints of rates of hospitalization and procedural complications., Results: CRT upgrade was performed in 75.5% of CRT-eligible patients with pre-existing ICD (n = 15,803). Presence of left bundle branch block conduction was the strongest predictor of CRT upgrade (odds ratio [OR] 4.56; 95% confidence interval [CI] 4.08-5.11; P <.0001). In both unadjusted and adjusted analyses, CRT upgrade was associated with a reduction in mortality at 3 years (unadjusted hazard ratio [HR] 0.80; 95% CI 0.70-0.92; P = .001; adjusted HR 0.84; 95% CI 0.72-0.98; P = .02, respectively). Compared to patients with ICD generator replacement only, patients who underwent CRT upgrade experienced no different 3-year rates of hospitalization (adjusted HR 1.01; 95% CI 0.91-1.12; P = .81) or 1-year periprocedural complication rates (adjusted HR 1.07; 95% CI 0.79-1.45; P = .66)., Conclusion: In a national registry of CRT-eligible patients with pre-existing ICD, upgrade to CRT was associated with lower rates of mortality than continued medical management., (Copyright © 2020 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF