1. Paroxysmal atrial fibrillation ablation with a novel temperature-controlled CF-sensing catheter: Q-FFICIENCY clinical and healthcare utilization benefits.
- Author
-
Hussein AA, Delaughter MC, Monir G, Natale A, Dukkipati S, Oza S, Daoud E, Di Biase L, Mansour M, Fishel R, Valderrabano M, Ellenbogen K, and Osorio J
- Subjects
- Humans, Prospective Studies, Quality of Life, Temperature, Treatment Outcome, Catheters, Anti-Arrhythmia Agents therapeutic use, Patient Acceptance of Health Care, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery, Atrial Fibrillation drug therapy, Pulmonary Veins surgery, Catheter Ablation adverse effects
- Abstract
Introduction: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants., Methods: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization., Results: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively., Conclusions: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization., (© 2023 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.)
- Published
- 2023
- Full Text
- View/download PDF