1. Plasma Fibrinogen as a Diagnostic Marker of Infection in Patients with Nonunions
- Author
-
Ming Chen, Yi-xin Chen, Xu-sheng Qiu, Xiang-Jin Wang, Zhen Wang, and Zitao Zhang
- Subjects
musculoskeletal diseases ,0301 basic medicine ,medicine.medical_specialty ,030106 microbiology ,Nonunion ,Fibrinogen ,Gastroenterology ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,White blood cell ,medicine ,Pharmacology (medical) ,030212 general & internal medicine ,Pharmacology ,medicine.diagnostic_test ,Receiver operating characteristic ,business.industry ,Area under the curve ,medicine.disease ,surgical procedures, operative ,Infectious Diseases ,medicine.anatomical_structure ,Erythrocyte sedimentation rate ,Biomarker (medicine) ,Aseptic processing ,business ,medicine.drug - Abstract
Background The timely and accurate diagnosis of infected nonunion is challenging, and there is a need for more efficient biomarkers. Previous studies have shown that fibrinogen plays an important role in mediating inflammation in bacterial infections and, therefore, could be a valuable biomarker for infected nonunion. The purpose of this study was to evaluate and compare the performance of plasma fibrinogen and other traditional blood markers for the diagnosis of infected nonunion. Materials and Methods We retrospectively studied 146 patients who underwent surgery for primary nonunion between January 2018 and January 2020. The patients were divided into those with infected nonunion (n = 55) and those with aseptic nonunion (n = 91). The preoperatively analyzed parameters were plasma fibrinogen, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and white blood cell (WBC) count. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of the biomarkers, and Youden's index was calculated to determine their optimal cut-off values. Results The plasma fibrinogen values were significantly higher (p < 0.001) in the patients with infected nonunion than in those with aseptic nonunion. ROC curve analysis showed that plasma fibrinogen had a high value of area under the curve (0.816), which indicated that it had good diagnostic ability. Further, at the optimal threshold value of 2.75 g/L, plasma fibrinogen had the highest sensitivity (78.2%; 95% CI = 64.6-87.8) and good specificity (82.4%; 95% CI, 72.7-89.3). Conclusion In comparison to the traditional markers of infection, plasma fibrinogen showed good diagnostic ability for the detection of infected nonunion. It may have potential as a practical and cost-efficient biomarker for the diagnosis of infected nonunion.
- Published
- 2020