Insulin pumps are equipped with advanced functions. Intensive training and adherence are required for optimum use of the technology. We aimed to assess the association of various key elements in insulin pump functions on blood glucose control.Patients on insulin pump therapy were enrolled. Insulin pumps were downloaded (CareLink(®) Pro 3 software; Medtronic Minimed, Northridge, CA), and data were collected over an 8-12-week period. Glycemic control of patients was classified as controlled (hemoglobin A1c [HbA1c] level of 7.5% or less in adults and 8% or less in children) and uncontrolled based on HbA1c level at enrollment. Variables studied were use of sensors and duration, frequency of blood glucose monitoring, Bolus Wizard (Medtronic Minimed) use, frequency of correction boluses, and frequency of cannula changing.Seventy-two patients were enrolled (50 children). Median age was 12 years for children and 27.5 years for adults. Respective median numbers of blood glucose checks were 4.4 and 3.2 for controlled and uncontrolled children (P0.021) and 3.1 and 2.8 for controlled and uncontrolled adults, respectively. Respective frequency of Bolus Wizard use per day showed a median of 6 and 4.15 for controlled and uncontrolled children (P0.001) and 3.8 and 3.5 for controlled and uncontrolled adults. Controlled children wore sensors for longer (5 vs. 2.9 days/week) and did more corrections (3.9 vs. 2.5). There was no difference in the frequency of changing the infusion cannula in children's or adults' groups.We conclude that the frequency of blood glucose monitoring and Bolus Wizard use have a favorable association with glycemic control. These observations were more significant in the children's groups. Our data shows that patients with better control tend to bolus more for correction and wear sensors longer.