1. Reliability assessment of hyperspectral imaging with the HyperView™ system for lower extremity superficial tissue oxygenation in young healthy volunteers
- Author
-
Simone F. Kleiss, Marieke Haalboom, Reinoud P H Bokkers, Clark J. Zeebregts, Mostafa El Moumni, Richte C. L. Schuurmann, Kirsten F. Ma, Jean-Paul P.M. de Vries, Man, Biomaterials and Microbes (MBM), Basic and Translational Research and Imaging Methodology Development in Groningen (BRIDGE), Robotics and image-guided minimally-invasive surgery (ROBOTICS), and Multi-Modality Medical Imaging
- Subjects
Adult ,Hyperspectral imaging ,Tissue perfusion ,030209 endocrinology & metabolism ,Health Informatics ,030204 cardiovascular system & hematology ,Critical Care and Intensive Care Medicine ,Young Adult ,03 medical and health sciences ,0302 clinical medicine ,Healthy volunteers ,Humans ,Medicine ,Generalizability theory ,Prospective Studies ,Transcutaneous oxygen pressure ,Prospective cohort study ,Reliability (statistics) ,Lower extremity ,business.industry ,Reproducibility of Results ,Healthy Volunteers ,Anesthesiology and Pain Medicine ,Tissue oxygenation ,Transcutaneous oxygen ,Nuclear medicine ,business ,Perfusion - Abstract
Purpose: Hyperspectral imaging (HSI) is a noninvasive spectroscopy technique for determining superficial tissue oxygenation. The HyperView™ system is a hand-held camera that enables perfusion image acquisition. The evaluation of superficial tissue oxygenation is warranted in the evaluation of patients with peripheral arterial disease. The aim was to determine the reliability of repeated HSI measurements. Methods: In this prospective cohort study, HSI was performed on 50 healthy volunteers with a mean age of 26.4 ± 2.5 years, at the lower extremity. Two independent observers performed HSI during two subsequent measurement sessions. Short term test–retest reliability and intra- and inter-observer reliability were determined, and generalizability and decision studies were performed. Transcutaneous oxygen pressure (TcPo2) measurements were also performed. Results: The short term test–retest reliability was good for the HSI values determined at the lower extremity, ranging from 0.72 to 0.90. Intra- and inter-observer reliability determined at different days were poor to moderate for both HSI (0.24 to 0.71 and 0.30 to 0.58, respectively) and TcPo2 (0.54 and 0.56, and 0.51 and 0.31, respectively). Reliability can be increased to >0.75 by averaging two measurements on different days. Conclusion: This study showed good short term test–retest reliability for HSI measurements, however low intra- and inter-observer reliability was observed for tissue oxygenation measurements with both HSI and TcPo2 performed at separate days in young healthy volunteers. Reliability of HSI can be improved when determined as a mean of two measurements taken on different days.
- Published
- 2021
- Full Text
- View/download PDF