1. Simultaneous determination of three endogenous chiral thiol compounds in serum from humans at normal and stress states using ultrahigh-performance liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry.
- Author
-
Ma Q, Man X, Xu CY, Huo J, Qi C, Shi Q, Nan J, and Min JZ
- Subjects
- Adult, Calibration, Chromatography, High Pressure Liquid, Female, Healthy Volunteers, Humans, Limit of Detection, Male, Organophosphorus Compounds chemical synthesis, Organophosphorus Compounds chemistry, Reproducibility of Results, Statistics as Topic, Stereoisomerism, Time Factors, Young Adult, Mass Spectrometry methods, Stress, Psychological blood, Sulfhydryl Compounds blood, Sulfhydryl Compounds chemistry
- Abstract
Measurement of chiral thiol compounds such as glutathione (GSH), cysteine (Cys), and homocysteine (Hcy) in human serum plays an important role in the early diagnosis and warning of cardiovascular disease, neurodegenerative disease, and cancer. We developed a novel chiral mass spectrometry derivatization reagent, (R)-(5-(3-isothiocyanatopyrrolidin-1-yl)-5-oxopentyl) triphenylphosphonium (NCS-OTPP), with triphenylphosphine (TPP) as a basic structure carrying a permanent positive charge for the diastereomeric separation of chiral thiol compounds by ultrahigh-performance liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS). A novel method was developed for simultaneous determination of three kinds of chiral thiol compounds based on the NCS-OTPP derivatization method. Three kinds of chiral thiol compounds on a YMC Triart C18 (2.0 × 150 mm, 1.9 μm) column with Rs were 1.56-1.68. The protonated precursor to product ion transitions monitored for GSH was m/z 780.16→747.24/473.18, Cys was m/z 594.20→561.18/473.18, and Hcy was m/z 608.21→575.19/473.18. An excellent linearity for all the analytes with correlation coefficients ≥ 0.9995 and suitable precision with inter-day and intra-day coefficients of variation RSDs was 0.83-4.06% and 0.95-3.11%. Satisfactory accuracy with recoveries between 83.73 and 103.35% was observed. The limit of detection (S/N = 3) was 2.4-7.2 fmol. Furthermore, the method was successfully applied to the simultaneous determination of three kinds of free and total thiol compounds in serum from 10 healthy volunteers at normal and stress states., Competing Interests: Declaration of Competing Interest The authors declare that there are no conflicts of interest., (Copyright © 2021 Elsevier B.V. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF