1. Non‐contrast based approach for liver function quantification using Bayesian‐based intravoxel incoherent motion diffusion weighted imaging: A pilot study.
- Author
-
Phonlakrai, Monchai, Ramadan, Saadallah, Simpson, John, Skehan, Kate, Goodwin, Jonathan, Trada, Yuvnik, Martin, Jarad, Sridharan, Swetha, Gan, Lay Theng, Siddique, Sabbir Hossain, and Greer, Peter
- Subjects
DIFFUSION magnetic resonance imaging ,DIAGNOSTIC imaging ,PEARSON correlation (Statistics) ,MAGNETIC resonance imaging ,LIVER ,STATISTICAL correlation ,INTRAHEPATIC bile ducts ,VOXEL-based morphometry - Abstract
Purpose: Liver cirrhosis disrupts liver function and tissue perfusion, detectable by magnetic resonance imaging (MRI). Assessing liver function at the voxel level with 13‐b value intravoxel incoherent motion diffusion‐weighted imaging (IVIM‐DWI) could aid in radiation therapy liver‐sparing treatment for patients with early impairment. This study aimed to evaluate the feasibility of IVIM‐DWI for liver function assessment and correlate it with other multiparametric (mp) MRI methods at the voxel level. Method: This study investigates the variability of apparent diffusion coefficient (ADC) derived from 13‐b value IVIM‐DWI and B1‐corrected dual flip angle (DFA) T1 mapping. Experiments were conducted in‐vitro with QIBA and NIST phantoms and in 10 healthy volunteers for IVIM‐DWI. Additionally, 12 patients underwent an mp‐MRI examination. The imaging protocol included a 13‐b value IVIM‐DWI sequence for generating IVIM parametric maps. B1‐corrected DFA T1 pulse sequence was used for generating T1 maps, and Gadoxatate low temporal resolution dynamic contrast‐enhanced (LTR‐DCE) MRI was used for generating the Hepatic extraction fraction (HEF) map. The Mann‐Whitney U test was employed to compare IVIM‐DWI parameters (Pure Diffusion, Dslow; Pseudo diffusion, Dfast; and Perfusion Fraction, Fp) between the healthy volunteer and patient groups. Furthermore, in the patient group, statistical correlations were assessed at a voxel level between LTR‐DCE MRI‐derived HEF, T1 post‐Gadoxetate administration, ΔT1%, and various IVIM parameters using Pearson correlation. Results: For‐vitro measurements, the maximum coefficient of variation of the ADC and T1 parameters was 12.4% and 16.1%, respectively. The results also showed that Fp and Dfast were able to distinguish between healthy liver function and mild liver function impairment at the global level, with p = 0.002 for Fp and p < 0.001 for Dfast. Within the patient group, these parameters also exhibited a moderate correlation with HEF at the voxel level. Conclusion: Overall, the study highlighted the potential of Dfast and Fp for detecting liver function impairment at both global and pixel levels. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF