1. The impact of reader fatigue on the accuracy of capsule endoscopy interpretation
- Author
-
Sabina Beg, Tim Card, Reena Sidhu, Ewa Wronska, Krish Ragunath, Hey-Long Ching, Anastasios Koulaouzidis, Diana Yung, Simon Panter, Mark Mcalindon, Matthew Johnson, Arun Kurup, Anthony Shonde, Miliedis San-Juan Acosta, Stefano Sansone, Ebby Simmon, Victoria Thurston, Ailish Healy, Stefania Chetcuti Zammit, John Schembri, Michelle S Lau, Ching Lam, Mohammed Nizamuddin, Andrew Baxter, Jay Patel, Tom Archer, Phillip Oppong, Frank Phillips, Tara Dorn, Waleed Fateen, Jonathan White, Shivkumar Budihal, Huey Tan, and Rajini Tiwari
- Subjects
Male ,medicine.medical_specialty ,Psychometrics ,media_common.quotation_subject ,Audiology ,Sitting ,Capsule Endoscopy ,Prospective evaluation ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,Capsule endoscopy ,law ,Reading (process) ,Image Interpretation, Computer-Assisted ,Intestinal Neoplasms ,medicine ,Humans ,Prospective Studies ,Early Detection of Cancer ,media_common ,Psychomotor learning ,Hepatology ,Lesion detection ,business.industry ,Gastroenterology ,Capsule ,Mental Fatigue ,Logistic Models ,030220 oncology & carcinogenesis ,Female ,030211 gastroenterology & hepatology ,Clinical Competence ,business ,Vigilance (psychology) - Abstract
Background and aims Capsule endoscopy (CE) interpretation requires the review of many thousands of images, with lesions often limited to just a few frames. In this study we aim to determine whether lesion detection declines according to the number of capsule videos read. Methods 32 participants, 16 of which were novices (NR) and 16 experienced (ER) capsule readers took part in this prospective evaluation study. Participants read six capsule cases with a variety of lesions, in a randomly assigned order during a single sitting. Psychomotor Vigilance Tests and Fatigue Scores were recorded prior to commencing and then after every two capsules read. Changes in lesion detection and measures of fatigue were assessed across the duration of the study. Results Mean agreement with the predefined lesions was 48.3% (SD:16.1), and 21.3% (SD:15.1) for the experienced and novice readers respectively. Lesion detection declined amongst experienced reader after the first study (p = 0.01), but remained stable after subsequent capsules read, while NR accuracy was unaffected by capsule numbers read. Objective measures of fatigue did not correlate with reading accuracy. Conclusion This study demonstrates that reader accuracy declines after reading just one capsule study. Subjective and objective measures of fatigue were not sufficient to predict the onset of the effects of fatigue.
- Published
- 2021