1. Design and test results of a front-end ASIC for radiation detectors
- Author
-
Zhang Yacong, Ji Lijiu, Chen Zhongjian, Lu Wengao, and Zhao Baoying
- Subjects
Physics ,business.industry ,Amplifier ,Detector ,Electrical engineering ,Integrated circuit design ,Current source ,Noise (electronics) ,Particle detector ,law.invention ,CMOS ,law ,Optoelectronics ,Resistor ,business - Abstract
A front-end ASIC for semiconductor radiation detectors is presented. It is composed of a Charge Sensitive Amplifier (CSA), a pulse shaper, and a Peak Detect and Hold (PDH) circuit. Poly-resistor is used as source degeneration component to reduce the noise of current source in the CSA. The ASIC has been designed in a 0.5 ?m CMOS DPTM technology and tested with Verigy 93000. The gain (PDH excluded) is 78.5 mV/fC and the Equivalent Noise Charge (ENC) with detector disconnected is 800-900 e. The power dissipation without the output buffer is about 2.6 mW.
- Published
- 2008
- Full Text