1. Practical Application of Multivendor MRI-Based R2* Mapping for Liver Iron Quantification at 1.5 T and 3.0 T.
- Author
-
Simchick G, Zhao R, Yuan Q, Ghasabeh MA, Ruschke S, Karampinos DC, Harris DT, do Vale Souza R, Mattison RJ, Jeng MR, Pedrosa I, Kamel IR, Vasanawala S, Yokoo T, Reeder SB, and Hernando D
- Subjects
- Humans, Male, Female, Adult, Prospective Studies, Middle Aged, Reproducibility of Results, Calibration, Image Processing, Computer-Assisted methods, Young Adult, Image Interpretation, Computer-Assisted methods, Liver diagnostic imaging, Magnetic Resonance Imaging methods, Iron, Iron Overload diagnostic imaging
- Abstract
Background: Recent multicenter, multivendor MRI-based R2* vs. liver iron concentration (LIC) calibrations (i.e., MCMV calibrations) may facilitate broad clinical dissemination of R2*-based LIC quantification. However, these calibrations are based on a centralized offline R2* reconstruction, and their applicability with vendor-provided R2* maps is unclear., Purpose: To determine R2* ranges of agreement between the centralized and three MRI vendors' R2* reconstructions., Study Type: Prospective., Subjects: Two hundred and seven subjects (mean age 37.6 ± 19.6 years; 117 male) with known or suspected iron overload from four academic medical centers., Field Strength/sequence: Standardized multiecho spoiled gradient echo sequence at 1.5 T and 3.0 T for R2* mapping and a multiple spin-echo sequence at 1.5 T for LIC quantification. MRI vendors: GE Healthcare, Philips Healthcare, and Siemens Healthineers., Assessment: R2* maps were generated using both the centralized and vendor reconstructions, and ranges of agreement were determined. R2*-LIC linear calibrations were determined for each site, field strength, and reconstruction and compared with the MCMV calibrations., Statistical Tests: Bland-Altman analysis to determine ranges of agreement. Linear regression, analysis of covariance F tests, and Tukey's multiple comparison testing to assess reproducibility of calibrations across sites and vendors. A P value <0.05 was considered significant., Results: The upper limits of R2* ranges of agreement were approximately 500, 375, and 330 s
-1 for GE, Philips, and Siemens reconstructions, respectively, at 1.5 T and approximately 700 and 800 s-1 for GE and Philips, respectively, at 3.0 T. Within the R2* ranges of agreement, vendor R2*-LIC calibrations demonstrated high reproducibility (no significant differences between slopes or intercepts; P ≥ 0.06) and agreed with the MCMV calibrations (overlapping 95% confidence intervals)., Data Conclusion: Based on the determined upper limits, R2* measurements obtained from vendor-provided R2* maps may be reliably and practically used to quantify LIC less than approximately 8-13 mg/g using the MCMV calibrations and similar acquisition parameters as this study., Evidence Level: 1 TECHNICAL EFFICACY: Stage 3., (© 2024 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)- Published
- 2025