1. The pEGASUS-HPC stent system for stent-assisted coiling of cerebral aneurysms: a multicenter case series.
- Author
-
Lobsien D, Holtmannspoetter M, Eff F, Berlis A, Maurer CJ, Behme D, Diamandis E, Gawlitza M, Fiorella D, Princiotta C, Cirillo L, Dall'Olio M, Keston P, Klisch J, and Nania A
- Subjects
- Humans, Middle Aged, Female, Male, Aged, Retrospective Studies, Adult, Endovascular Procedures methods, Endovascular Procedures instrumentation, Treatment Outcome, Polymers, Intracranial Aneurysm diagnostic imaging, Intracranial Aneurysm therapy, Intracranial Aneurysm surgery, Stents adverse effects, Embolization, Therapeutic instrumentation, Embolization, Therapeutic methods
- Abstract
Background: Stent-assisted coiling (SAC) is a well-established method for treatment of wide-necked intracranial aneurysms. In this multicenter, retrospective case series we evaluated SAC with a new low-profile, laser-cut stent with an antithrombogenic hydrophilic polymer coating (pEGASUS-HPC) for the treatment of intracranial aneurysms., Methods: Patients treated with pEGASUS-HPC SAC for one or more intracranial aneurysms were retrospectively included. Clinical, imaging, and procedural parameters as well as clinical and imaging follow-up data were recorded., Results: We treated 53 aneurysms in 52 patients in six neurovascular centers between August 2021 and November 2022. Thirty-seven patients (69.8%) were female. Mean age was 57 (±11.7) years. Twenty-nine patients were treated electively, 23 in the acute phase (22 with aneurysmal subarachnoid hemorrhage (SAH), and 1 with a partially thrombosed aneurysm causing ischemic events). One intraprocedural thromboembolic event and three postprocedural ischemic complications occurred in two (8.7 %) of the SAH patients and in one of the elective patients (3.45%). Overall aneurysm occlusion was Raymond Roy (RR) I in 36 (69.2%), RR II in 9, and RR III in 9 cases. Follow-up imaging was available for 23 patients after an average of 147.7 (±59.6) days demonstrating RR I occlusion in 22 (95.5%) and RR II in 1 patient., Conclusion: SAC with the pEGASUS-HPC stent system demonstrates rates of periprocedural safety and effectiveness that are comparable with previously reported series for stent-assisted coil embolization., Competing Interests: Competing interests: All authors: phenox GmbH organized online meetings of the centers during the initiation of the work. DL: phenox – travel expenses, speaker honoraria (money paid to institution). MH: Balt, Medtronic, Microvention, Cerenovus, Stryker, Rapid Medical, phenox – consulting fees; Penumbra – speaker honoraria; Medtronic – steering committee “Inspire” Study. FE: did not disclose competing interests. AB: none. CJM: none. DB: phenox, Acandis, Stryker, Vesalio – consulting fees; Acandis – speaker honoraria; Acandis – travel expenses. ED: none. DF: Medtronic, Cerenovous, Microvention, Penumbra, Stryker, Balt USA, Seimens, Mentice, Neurogami, Rapid.AI, Rapid Medical, Q’apel Medical, Arsenal Medical, phenox, Scientia, NVMed, Perfuze, Vesalio – consulting fees; Medtronic, Cerenovous, Microvention, Penumbra, Stryker, Balt USA, Q’apel Medical – speaker honoraria; Medtronic, Cerenovous, Microvention, Penumbra, Stryker, Balt USA, Seimens, Mentice, Neurogami, Rapid.AI, Rapid Medical, Q’apel Medical, Arsenal Medical, phenox, Scientia, NVMed, Perfuze, Vesalio – travel expenses; Scientia, MENTICE, Neurogami, NVMed, Perfuze – leadership role; Scientia, Perfuze, NVMED, Mentice, Neurogami – stock options. MG: phenox, Microvention, Balt – consulting; phenox – speaker honoraria. CP: none. LC: none. MD: none. PK: Medtronic, Stryker, Microvention – consulting fees; Stryker, Oxford Heartbeat – grants. JK: phenox – travel expenses, speaker honoraria; phenox, Microvention – consulting fees (money paid to institution). AN: none., (© Author(s) (or their employer(s)) 2025. No commercial re-use. See rights and permissions. Published by BMJ Group.)
- Published
- 2024
- Full Text
- View/download PDF