22 results on '"Forlenza GP"'
Search Results
2. Psychosocial outcomes with the Omnipod® 5 Automated Insulin Delivery System in caregivers of very young children with type 1 diabetes.
- Author
-
MacLeish SA, Hood KK, Polonsky WH, Wood JR, Bode BW, Forlenza GP, Laffel LM, Buckingham BA, Criego AB, Schoelwer MJ, DeSalvo DJ, Sherr JL, Hansen DW, Conroy LR, Huyett LM, Vienneau TE, and Ly TT
- Subjects
- Humans, Child, Preschool, Female, Male, Hypoglycemia prevention & control, Hypoglycemia chemically induced, Surveys and Questionnaires, Sleep Quality, Adult, Diabetes Mellitus, Type 1 drug therapy, Diabetes Mellitus, Type 1 psychology, Diabetes Mellitus, Type 1 blood, Caregivers psychology, Insulin Infusion Systems, Insulin administration & dosage, Insulin therapeutic use, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use
- Abstract
Aim: Automated insulin delivery (AID) systems have demonstrated improved glycaemic outcomes in people with type 1 diabetes (T1D), yet limited data exist on these systems in very young children and their impact on caregivers. We evaluated psychosocial outcomes following use of the tubeless Omnipod® 5 AID System in caregivers of very young children., Materials and Methods: This 3-month single-arm, multicentre, pivotal clinical trial enrolled 80 children aged 2.0-5.9 years with T1D to use the Omnipod 5 AID System. Caregivers completed questionnaires assessing psychosocial outcomes-diabetes distress (Problem Areas in Diabetes), hypoglycaemia confidence (Hypoglycemia Confidence Scale), well-being (World Health Organization 5 Well-Being Index), sleep quality (Pittsburgh Sleep Quality Index), insulin delivery satisfaction (Insulin Delivery Satisfaction Survey) and system usability (System Usability Scale) at baseline with standard therapy and after 3 months of AID use., Results: Following 3 months of Omnipod 5 use, caregivers experienced significant improvements across all measures, including diabetes-related psychosocial outcomes (Problem Areas in Diabetes; p < 0.0001, Hypoglycemia Confidence Scale; p < 0.01), well-being (World Health Organization 5 Well-Being Index; p < 0.0001) and perceived system usability (System Usability Scale; p < 0.0001). Significant improvements were seen in the Pittsburgh Sleep Quality Index total score and the overall sleep quality, sleep duration and efficiency subscales (all p < 0.05). Insulin Delivery Satisfaction Survey scores improved on all subscales (greater satisfaction, reduced burden and reduced inconvenience; all p < 0.0001)., Conclusions: Caregivers face unique challenges when managing T1D in very young children. While glycaemic metrics have unquestioned importance, these results evaluating psychosocial outcomes reveal additional meaningful benefits and suggest that the Omnipod 5 AID System alleviates some of the burdens caregivers face with diabetes management., (© 2024 Insulet Corporation and The Author(s). Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.)
- Published
- 2024
- Full Text
- View/download PDF
3. Real-World Evidence of Omnipod ® 5 Automated Insulin Delivery System Use in 69,902 People with Type 1 Diabetes.
- Author
-
Forlenza GP, DeSalvo DJ, Aleppo G, Wilmot EG, Berget C, Huyett LM, Hadjiyianni I, Méndez JJ, Conroy LR, Ly TT, and Sherr JL
- Subjects
- Humans, Adult, Retrospective Studies, Male, Child, Adolescent, Female, Middle Aged, Young Adult, United States, Child, Preschool, Blood Glucose Self-Monitoring, Glycemic Control methods, Aged, Diabetes Mellitus, Type 1 drug therapy, Diabetes Mellitus, Type 1 blood, Insulin Infusion Systems, Insulin administration & dosage, Insulin therapeutic use, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use, Blood Glucose analysis
- Abstract
Background: The Omnipod
® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL ( n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.- Published
- 2024
- Full Text
- View/download PDF
4. Glycemic Outcomes Persist for up to 2 Years in Very Young Children with the Omnipod ® 5 Automated Insulin Delivery System.
- Author
-
DeSalvo DJ, Bode BW, Forlenza GP, Laffel LM, Buckingham BA, Criego AB, Schoelwer M, MacLeish SA, Sherr JL, Hansen DW, and Ly TT
- Subjects
- Humans, Child, Preschool, Female, Male, Hypoglycemia prevention & control, Treatment Outcome, Glycemic Control methods, Blood Glucose Self-Monitoring, Diabetes Mellitus, Type 1 drug therapy, Diabetes Mellitus, Type 1 blood, Insulin Infusion Systems, Insulin administration & dosage, Insulin therapeutic use, Blood Glucose analysis, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use, Glycated Hemoglobin analysis
- Abstract
Background: To evaluate the long-term safety and effectiveness of the Omnipod
® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants ( N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use ( P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial ( P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase ( P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.- Published
- 2024
- Full Text
- View/download PDF
5. Reducing Diabetes Burden in Medtronic's Automated Insulin Delivery Systems.
- Author
-
Forlenza GP, Dai Z, Niu F, and Shin JJ
- Subjects
- Adult, Humans, Child, Insulin therapeutic use, Blood Glucose, Blood Glucose Self-Monitoring, Insulin Infusion Systems, Glucose, Hypoglycemic Agents therapeutic use, Diabetes Mellitus, Type 1 drug therapy
- Abstract
Background: The MiniMed™ 780G advanced hybrid closed-loop system (MM780G) builds on the basal automation and low-glucose protection features of the MiniMed™ 670G and 770G systems. While previous publications have focused on glycemic control improvements with MM780G, burden reduction has not been fully described. Methods: Data from two 3-month pivotal trials for the MM670G with Guardian™ Sensor 3 (GS3) (104 adults; 125 children) and MM780G with Guardian™ 4 Sensor (G4S) (67 adults;109 children) were compared. Real-world data (RWD) from United States users ( N = 3851) transitioning from MM770G+GS3 to MM780G+G4S were also analyzed. Analyses included a new metric for diabetes management burden (i.e., pentagon composite metric), glycemic outcomes and system burden (e.g., closed-loop exits and fingersticks per day). Results: Diabetes burden metric (-22.8% and -28.5%), time in range (+3.1% [* P = 0.035] and +6.4% [ P < 0.001]) and time below range (-1.8% [* P < 0.001] and -0.7% [* P < 0.001]) significantly improved, compared to MM670G for adult and pediatric participants, respectively. The pediatric mean sensor glucose (SG) reduced by -8.6 mg/dL (* P < 0.001), while the adults' saw no change. Closed-loop use significantly increased for both cohorts (+17.1% [* P < 0.001] and +20.5% [* P < 0.001]). Closed-loop exits were significantly reduced to about 1 per week (-0.5 [* P < 0.001] and -0.7 [* P < 0.001]); fingerstick tests were also reduced (-6.2 [* P < 0.001] and -6.9 [* P < 0.001]). Similar outcomes were observed from U.S. RWD. Conclusions: MiniMed™ 780G with G4S use was associated with significant reduction in diabetes management burden with fewer closed-loop exits, fingersticks and other interactions, and improvements in glycemic control when compared to the MiniMed™ 670G with GS3.
- Published
- 2024
- Full Text
- View/download PDF
6. Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes.
- Author
-
Wadwa RP, Reed ZW, Buckingham BA, DeBoer MD, Ekhlaspour L, Forlenza GP, Schoelwer M, Lum J, Kollman C, Beck RW, and Breton MD
- Subjects
- Child, Child, Preschool, Humans, Blood Glucose Self-Monitoring, Glycated Hemoglobin analysis, Blood Glucose analysis, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents adverse effects, Hypoglycemic Agents therapeutic use, Insulin administration & dosage, Insulin adverse effects, Insulin therapeutic use, Insulin Infusion Systems adverse effects
- Abstract
Background: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear., Methods: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes., Results: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group., Conclusions: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.)., (Copyright © 2023 Massachusetts Medical Society.)
- Published
- 2023
- Full Text
- View/download PDF
7. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes.
- Author
-
Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer M, Ruedy KJ, Jost E, Carria L, Emory E, Hsu LJ, Oliveri M, Kollman CC, Dokken BB, Weinzimer SA, DeBoer MD, Buckingham BA, Cherñavvsky D, and Wadwa RP
- Subjects
- Adolescent, Blood Glucose analysis, Child, Diabetes Mellitus, Type 1 blood, Diabetic Ketoacidosis etiology, Female, Glycated Hemoglobin analysis, Humans, Hypoglycemia chemically induced, Hypoglycemic Agents adverse effects, Injections, Subcutaneous, Insulin adverse effects, Male, Pancreas, Artificial, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Infusion Pumps, Implantable, Insulin administration & dosage, Insulin Infusion Systems adverse effects
- Abstract
Background: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes., Methods: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring., Results: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group., Conclusions: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.)., (Copyright © 2020 Massachusetts Medical Society.)
- Published
- 2020
- Full Text
- View/download PDF
8. Suicide via Intentional Insulin Overdose Through First Commercial Hybrid Closed-Loop.
- Author
-
Shah VN and Forlenza GP
- Subjects
- Biomarkers blood, Blood Glucose metabolism, Blood Glucose Self-Monitoring instrumentation, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 diagnosis, Drug Overdose, Fatal Outcome, Glycated Hemoglobin metabolism, Humans, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Male, Middle Aged, Blood Glucose drug effects, Diabetes Mellitus, Type 1 diagnostic imaging, Hypoglycemic Agents poisoning, Insulin poisoning, Insulin Infusion Systems adverse effects, Suicide
- Published
- 2020
- Full Text
- View/download PDF
9. Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes.
- Author
-
Brown SA, Kovatchev BP, Raghinaru D, Lum JW, Buckingham BA, Kudva YC, Laffel LM, Levy CJ, Pinsker JE, Wadwa RP, Dassau E, Doyle FJ 3rd, Anderson SM, Church MM, Dadlani V, Ekhlaspour L, Forlenza GP, Isganaitis E, Lam DW, Kollman C, and Beck RW
- Subjects
- Adolescent, Adult, Aged, Blood Glucose analysis, Diabetes Mellitus, Type 1 blood, Equipment Design, Female, Glycated Hemoglobin analysis, Humans, Hypoglycemic Agents adverse effects, Insulin adverse effects, Male, Middle Aged, Young Adult, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems adverse effects, Pancreas, Artificial adverse effects
- Abstract
Background: Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes., Methods: In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring., Results: A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group., Conclusions: In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.)., (Copyright © 2019 Massachusetts Medical Society.)
- Published
- 2019
- Full Text
- View/download PDF
10. Use of Artificial Intelligence to Improve Diabetes Outcomes in Patients Using Multiple Daily Injections Therapy.
- Author
-
Forlenza GP
- Subjects
- Diabetes Mellitus, Type 1 blood, Glycated Hemoglobin analysis, Humans, Injections, Subcutaneous, Artificial Intelligence, Biomedical Technology methods, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage
- Published
- 2019
- Full Text
- View/download PDF
11. Performance of Omnipod Personalized Model Predictive Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Diabetes.
- Author
-
Forlenza GP, Buckingham BA, Christiansen MP, Wadwa RP, Peyser TA, Lee JB, O'Connor J, Dassau E, Huyett LM, Layne JE, and Ly TT
- Subjects
- Adolescent, Adult, Aged, Algorithms, Diabetes Mellitus, Type 1 blood, Exercise, Female, Humans, Male, Middle Aged, Young Adult, Blood Glucose analysis, Blood Glucose Self-Monitoring instrumentation, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Insulin Infusion Systems
- Abstract
Background: The objective of this study was to assess the safety and performance of the Omnipod
® personalized model predictive control (MPC) algorithm with variable glucose setpoints and moderate intensity exercise using an investigational device in adults with type 1 diabetes (T1D). Materials and Methods: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient standard treatment phase. Adults aged 18-65 years with T1D and HbA1c between 6.0% and 10.0% were eligible. Subjects completed two moderate intensity exercise sessions of >30 min duration on consecutive days: the first with the glucose set point increased from 130 to 150 mg/dL and the second with a temporary basal rate of 50%, both started 90 min pre-exercise. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Results: Twelve subjects participated in the study, with (mean ± standard deviation) age 36.5 ± 14.4 years, diabetes duration 21.7 ± 15.7 years, HbA1c 7.6% ± 1.1%, and total daily dose 0.60 ± 0.22 U/kg. Outcomes for the 54-h HCL period were mean glucose: 136 ± 14 mg/dL, percentage time <70 mg/dL: 1.4% ± 1.3%, 70-180 mg/dL: 85.1% ± 9.3%, and ≥250 mg/dL: 1.8% ± 2.4%. In the 12-h period after exercise start, percentage time <70 mg/dL was 1.4% ± 2.7% with the raised glucose set point and 1.6% ± 3.0% with reduced basal rate. The percentage time <70 mg/dL overnight was 0% ± 0% on both study nights. Conclusions: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to variable glucose set points and with temporarily raised glucose set point or reduced basal rate 90 min in advance of moderate intensity exercise in adults with T1D.- Published
- 2019
- Full Text
- View/download PDF
12. The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability.
- Author
-
Anderson SM, Dassau E, Raghinaru D, Lum J, Brown SA, Pinsker JE, Church MM, Levy C, Lam D, Kudva YC, Buckingham B, Forlenza GP, Wadwa RP, Laffel L, Doyle FJ 3rd, DeVries JH, Renard E, Cobelli C, Boscari F, Del Favero S, and Kovatchev BP
- Subjects
- Adolescent, Adult, Aged, Algorithms, Blood Glucose Self-Monitoring, Diabetes Mellitus, Type 1 blood, Female, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Male, Middle Aged, Reproducibility of Results, Smartphone, Treatment Outcome, Young Adult, Blood Glucose analysis, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems, Pancreas, Artificial
- Abstract
Background: Use of artificial pancreas (AP) requires seamless interaction of device components, such as continuous glucose monitor (CGM), insulin pump, and control algorithm. Mobile AP configurations also include a smartphone as computational hub and gateway to cloud applications (e.g., remote monitoring and data review and analysis). This International Diabetes Closed-Loop study was designed to demonstrate and evaluate the operation of the inControl AP using different CGMs and pump modalities without changes to the user interface, user experience, and underlying controller., Methods: Forty-three patients with type 1 diabetes (T1D) were enrolled at 10 clinical centers (7 United States, 3 Europe) and 41 were included in the analyses (39% female, >95% non-Hispanic white, median T1D duration 16 years, median HbA1c 7.4%). Two CGMs and two insulin pumps were tested by different study participants/sites using the same system hub (a smartphone) during 2 weeks of in-home use., Results: The major difference between the system components was the stability of their wireless connections with the smartphone. The two sensors achieved similar rates of connectivity as measured by percentage time in closed loop (75% and 75%); however, the two pumps had markedly different closed-loop adherence (66% vs. 87%). When connected, all system configurations achieved similar glycemic outcomes on AP control (73% [mean] time in range: 70-180 mg/dL, and 1.7% [median] time <70 mg/dL)., Conclusions: CGMs and insulin pumps can be interchangeable in the same Mobile AP system, as long as these devices achieve certain levels of reliability and wireless connection stability.
- Published
- 2019
- Full Text
- View/download PDF
13. Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes.
- Author
-
Forlenza GP, Pinhas-Hamiel O, Liljenquist DR, Shulman DI, Bailey TS, Bode BW, Wood MA, Buckingham BA, Kaiserman KB, Shin J, Huang S, Lee SW, and Kaufman FR
- Subjects
- Adolescent, Blood Glucose analysis, Blood Glucose Self-Monitoring, Child, Diabetes Mellitus, Type 1 blood, Female, Glycated Hemoglobin analysis, Humans, Male, Treatment Outcome, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems statistics & numerical data
- Abstract
Objective: To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D)., Methods: Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week baseline run-in phase in Manual Mode followed by a 3-month study phase with Auto Mode enabled. Sensor glucose (SG), glycated hemoglobin (HbA
1c ), percentage of SG values across glucose ranges, and SG variability, during the run-in and study phases were compared. Participants underwent frequent sample testing with i-STAT® venous reference measurement during a hotel period (6 days/5 nights) to evaluate the system's continuous glucose monitoring performance., Results: Auto Mode was used a median of 81% of the time. From baseline to end of study, overall SG dropped by 6.9 ± 17.2 mg/dL (P < 0.001), HbA1c decreased from 7.9% ± 0.8% to 7.5% ± 0.6% (P < 0.001), percentage of time in target glucose range (70-180 mg/dL) increased from 56.2% ± 11.4% to 65.0% ± 7.7% (P < 0.001), and the SG coefficient of variation decreased from 39.6% ± 5.4% to 38.5% ± 3.8% (P = 0.009). The percentage of SG values within target glucose range was 68.2% ± 9.1% and that of i-STAT reference values was 65.6% ± 17.7%. The percentage of values within 20%/20 of the i-STAT reference was 85.2%. There were no episodes of severe hypoglycemia or diabetic ketoacidosis during the study phase., Conclusion: In-home use of MiniMed 670G system Auto Mode for 3 months by children with T1D, similar to MiniMed 670G system use by adolescents and adults with T1D, was safe and associated with reduced HbA1c levels and increased time in target glucose range, compared with baseline.- Published
- 2019
- Full Text
- View/download PDF
14. In-Clinic Evaluation of the MiniMed 670G System "Suspend Before Low" Feature in Children with Type 1 Diabetes.
- Author
-
Wood MA, Shulman DI, Forlenza GP, Bode BW, Pinhas-Hamiel O, Buckingham BA, Kaiserman KB, Liljenquist DR, Bailey TS, Shin J, Huang S, Chen X, Cordero TL, Lee SW, and Kaufman FR
- Subjects
- Adolescent, Blood Glucose Self-Monitoring instrumentation, Blood Glucose Self-Monitoring methods, Child, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 complications, Exercise physiology, Female, Humans, Hyperglycemia blood, Hyperglycemia etiology, Hyperglycemia prevention & control, Hypoglycemia blood, Hypoglycemia etiology, Insulin analysis, Male, Reference Values, Time Factors, Treatment Outcome, Algorithms, Blood Glucose analysis, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemia prevention & control, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
Background: The Medtronic predictive low-glucose management (PLGM) algorithm automatically stops insulin delivery when sensor glucose (SG) is predicted to reach or fall below a preset low-glucose value within the next 30 min, and resumes delivery after hypoglycemia recovery. The present study evaluated the PLGM algorithm performance of the MiniMed™ 670G system SmartGuard™ "suspend before low" feature in children aged 7-13 years with type 1 diabetes (T1D)., Method: Participants (N = 105, mean ± standard deviation of 10.8 ± 1.8 years) underwent an overnight in-clinic evaluation of the "suspend before low" feature with a preset low limit of 65 mg/dL. After exercise, frequent sample testing (FST) was conducted every 5 min if values were <70 mg/dL; every 15 min if 70-80 mg/dL; and every 30 min if >80 mg/dL. First-day performance of the Guardian™ Sensor 3 glucose sensor and continuous glucose monitoring system was also evaluated., Results: Activation of the "suspend before low" feature occurred in 79 of the 105 participants, 79.7% (63/79) did not result in SG falling below 65 mg/dL. Mean glucose at activation was 102 ± 19 mg/dL and the initial insulin suspension duration was 87.5 ± 32.7 min. Four hours after insulin resumption, mean reference glucose was 130 ± 42 mg/dL. Mean absolute relative difference between the FST reference glucose and SG values on the first day of sensor wear was 11.4%. For the 26 participants in whom the "suspend before low" feature did not activate, none involved a reference glucose value ≤65 mg/dL, suggesting that the PLGM algorithm performed as intended., Conclusion: In children aged 7-13 years with T1D, the "suspend before low" feature of the MiniMed 670G system demonstrated a hypoglycemia prevention rate of nearly 80% after exercise and did not involve rebound hyperglycemia. There were no events of severe hypoglycemia during the evaluation.
- Published
- 2018
- Full Text
- View/download PDF
15. Predictive Low-Glucose Suspend Reduces Hypoglycemia in Adults, Adolescents, and Children With Type 1 Diabetes in an At-Home Randomized Crossover Study: Results of the PROLOG Trial.
- Author
-
Forlenza GP, Li Z, Buckingham BA, Pinsker JE, Cengiz E, Wadwa RP, Ekhlaspour L, Church MM, Weinzimer SA, Jost E, Marcal T, Andre C, Carria L, Swanson V, Lum JW, Kollman C, Woodall W, and Beck RW
- Subjects
- Adolescent, Adult, Aged, Algorithms, Blood Glucose analysis, Child, Cross-Over Studies, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 diagnosis, Drug Delivery Systems, Female, Humans, Hypoglycemia blood, Hypoglycemia chemically induced, Male, Middle Aged, Monitoring, Ambulatory, Young Adult, Blood Glucose Self-Monitoring methods, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemia prevention & control, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
Objective: This study evaluated a new insulin delivery system designed to reduce insulin delivery when trends in continuous glucose monitoring (CGM) glucose concentrations predict future hypoglycemia., Research Design and Methods: Individuals with type 1 diabetes ( n = 103, age 6-72 years, mean HbA
1c 7.3% [56 mmol/mol]) participated in a 6-week randomized crossover trial to evaluate the efficacy and safety of a Tandem Diabetes Care t:slim X2 pump with Basal-IQ integrated with a Dexcom G5 sensor and a predictive low-glucose suspend algorithm (PLGS) compared with sensor-augmented pump (SAP) therapy. The primary outcome was CGM-measured time <70 mg/dL., Results: Both study periods were completed by 99% of participants; median CGM usage exceeded 90% in both arms. Median time <70 mg/dL was reduced from 3.6% at baseline to 2.6% during the 3-week period in the PLGS arm compared with 3.2% in the SAP arm (difference [PLGS - SAP] = -0.8%, 95% CI -1.1 to -0.5, P < 0.001). The corresponding mean values were 4.4%, 3.1%, and 4.5%, respectively, represent-ing a 31% reduction in the time <70 mg/dL with PLGS. There was no increase in mean glucose concentration (159 vs. 159 mg/dL, P = 0.40) or percentage of time spent >180 mg/dL (32% vs. 33%, P = 0.12). One severe hypoglycemic event occurred in the SAP arm and none in the PLGS arm. Mean pump suspension time was 104 min/day., Conclusions: The Tandem Diabetes Care Basal-IQ PLGS system significantly reduced hypoglycemia without rebound hyperglycemia, indicating that the system can benefit adults and youth with type 1 diabetes in improving glycemic control., (© 2018 by the American Diabetes Association.)- Published
- 2018
- Full Text
- View/download PDF
16. Performance of the Omnipod Personalized Model Predictive Control Algorithm with Meal Bolus Challenges in Adults with Type 1 Diabetes.
- Author
-
Buckingham BA, Christiansen MP, Forlenza GP, Wadwa RP, Peyser TA, Lee JB, O'Connor J, Dassau E, Huyett LM, Layne JE, and Ly TT
- Subjects
- Adult, Algorithms, Blood Glucose, Feeding Behavior, Female, Humans, Male, Middle Aged, Pancreas, Artificial, Postprandial Period, Young Adult, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage
- Abstract
Background: This study assessed the safety and performance of the Omnipod
® personalized model predictive control (MPC) algorithm using an investigational device in adults with type 1 diabetes in response to overestimated and missed meal boluses and extended boluses for high-fat meals., Materials and Methods: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient open-loop run-in phase. Adults aged 18-65 years with type 1 diabetes and HbA1c 6.0%-10.0% were eligible. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Glycemic responses for 4 h to a 130% overestimated bolus and a missed meal bolus were compared with a 100% bolus for identical meals, respectively. The 12-h postprandial responses to a high-fat meal were compared using either a standard or extended bolus., Results: Twelve subjects participated in the study, with (mean ± standard deviation): age 35.4 ± 14.1 years, diabetes duration 16.5 ± 9.3 years, HbA1c 7.7 ± 0.9%, and total daily dose 0.58 ± 0.19 U/kg. Outcomes for the 54-h HCL period were mean glucose 153 ± 15 mg/dL, percentage time <70 mg/dL [median (interquartile range)]: 0.0% (0.0-1.2%), 70-180 mg/dL: 76.1% ± 8.0%, and ≥250 mg/dL: 4.5% ± 3.6%. After both the 100% and 130% boluses, postprandial percentage time <70 mg/dL was 0.0% (0.0-0.0%) (P = 0.50). After the 100% and missed boluses, postprandial percentage time ≥250 mg/dL was 0.2% ± 0.6% and 10.3% ± 16.5%, respectively (P = 0.06). Postprandial percentages time ≥250 mg/dL and <70 mg/dL were similar with standard or extended boluses for a high-fat meal., Conclusions: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to overestimated, missed, and extended meal boluses in adults with type 1 diabetes.- Published
- 2018
- Full Text
- View/download PDF
17. Fully Closed-Loop Multiple Model Probabilistic Predictive Controller Artificial Pancreas Performance in Adolescents and Adults in a Supervised Hotel Setting.
- Author
-
Forlenza GP, Cameron FM, Ly TT, Lam D, Howsmon DP, Baysal N, Kulina G, Messer L, Clinton P, Levister C, Patek SD, Levy CJ, Wadwa RP, Maahs DM, Bequette BW, and Buckingham BA
- Subjects
- Adolescent, Adult, Blood Glucose Self-Monitoring, Diabetes Mellitus, Type 1 blood, Female, Humans, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Male, Treatment Outcome, Young Adult, Blood Glucose analysis, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Pancreas, Artificial
- Abstract
Background: Initial Food and Drug Administration-approved artificial pancreas (AP) systems will be hybrid closed-loop systems that require prandial meal announcements and will not eliminate the burden of premeal insulin dosing. Multiple model probabilistic predictive control (MMPPC) is a fully closed-loop system that uses probabilistic estimation of meals to allow for automated meal detection. In this study, we describe the safety and performance of the MMPPC system with announced and unannounced meals in a supervised hotel setting., Research Design and Methods: The Android phone-based AP system with remote monitoring was tested for 72 h in six adults and four adolescents across three clinical sites with daily exercise and meal challenges involving both three announced (manual bolus by patient) and six unannounced (no bolus by patient) meals. Safety criteria were predefined. Controller aggressiveness was adapted daily based on prior hypoglycemic events., Results: Mean 24-h continuous glucose monitor (CGM) was 157.4 ± 14.4 mg/dL, with 63.6 ± 9.2% of readings between 70 and 180 mg/dL, 2.9 ± 2.3% of readings <70 mg/dL, and 9.0 ± 3.9% of readings >250 mg/dL. Moderate hyperglycemia was relatively common with 24.6 ± 6.2% of readings between 180 and 250 mg/dL, primarily within 3 h after a meal. Overnight mean CGM was 139.6 ± 27.6 mg/dL, with 77.9 ± 16.4% between 70 and 180 mg/dL, 3.0 ± 4.5% <70 mg/dL, 17.1 ± 14.9% between 180 and 250 mg/dL, and 2.0 ± 4.5%> 250 mg/dL. Postprandial hyperglycemia was more common for unannounced meals compared with announced meals (4-h postmeal CGM 197.8 ± 44.1 vs. 140.6 ± 35.0 mg/dL; P < 0.001). No participants met safety stopping criteria., Conclusions: MMPPC was safe in a supervised setting despite meal and exercise challenges. Further studies are needed in a less supervised environment.
- Published
- 2018
- Full Text
- View/download PDF
18. Safety and Feasibility of the OmniPod Hybrid Closed-Loop System in Adult, Adolescent, and Pediatric Patients with Type 1 Diabetes Using a Personalized Model Predictive Control Algorithm.
- Author
-
Buckingham BA, Forlenza GP, Pinsker JE, Christiansen MP, Wadwa RP, Schneider J, Peyser TA, Dassau E, Lee JB, O'Connor J, Layne JE, and Ly TT
- Subjects
- Adolescent, Adult, Aged, Algorithms, Child, Diabetes Mellitus, Type 1 blood, Feasibility Studies, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Male, Middle Aged, Young Adult, Blood Glucose analysis, Blood Glucose Self-Monitoring instrumentation, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems adverse effects
- Abstract
Background: The safety and feasibility of the OmniPod personalized model predictive control (MPC) algorithm in adult, adolescent, and pediatric patients with type 1 diabetes were investigated., Methods: This multicenter, observational trial included a 1-week outpatient sensor-augmented pump open-loop phase and a 36-h inpatient hybrid closed-loop (HCL) phase with announced meals ranging from 30 to 90 g of carbohydrates and limited physical activity. Patients aged 6-65 years with HbA1c between 6.0% and 10.0% were eligible. The investigational system included a modified version of OmniPod, the Dexcom G4 505 Share
® AP System, and the personalized MPC algorithm running on a tablet computer. Primary endpoints included sensor glucose percentage of time in hypoglycemia <70 mg/dL and hyperglycemia >250 mg/dL. Additional glycemic targets were assessed., Results: The percentage of time <70 mg/dL during the 36-h HCL phase was mean (standard deviation): 0.7 (1.7) in adults receiving 80% meal bolus (n = 24), and 0.7 (1.2) in adults (n = 10), 2.0 (2.4) in adolescents (n = 12), and 2.0 (2.6) in pediatrics (n = 12) receiving 100% meal bolus. The overall hypoglycemia rate was 0.49 events/24 h. The percentage of time >250 mg/dL was 8.0 (7.5), 3.6 (3.7), 4.9 (6.3), and 6.7 (5.6) in the study groups, respectively. Percentage of time in the target range of 70-180 mg/dL was 69.5 (14.4), 73.0 (15.0), 72.6 (15.5), and 70.1 (12.3), respectively., Conclusions: The OmniPod personalized MPC algorithm performed well and was safe during day and night use in adult, adolescent, and pediatric patients with type 1 diabetes. Longer term studies will assess the safety and performance of the algorithm under free living conditions with extended use.- Published
- 2018
- Full Text
- View/download PDF
19. Optimizing Hybrid Closed-Loop Therapy in Adolescents and Emerging Adults Using the MiniMed 670G System.
- Author
-
Messer LH, Forlenza GP, Sherr JL, Wadwa RP, Buckingham BA, Weinzimer SA, Maahs DM, and Slover RH
- Subjects
- Adolescent, Adult, Aged, Blood Glucose drug effects, Blood Glucose metabolism, Blood Glucose Self-Monitoring instrumentation, Blood Glucose Self-Monitoring standards, Calibration, Female, Humans, Hyperglycemia blood, Hyperglycemia drug therapy, Male, Meals, Middle Aged, Young Adult, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems standards, Pancreas, Artificial standards
- Abstract
Objective: The MiniMed 670G System is the first commercial hybrid closed-loop (HCL) system for management of type 1 diabetes. Using data from adolescent and young adult participants, we compared insulin delivery patterns and time-in-range metrics in HCL (Auto Mode) and open loop (OL). System alerts, usage profiles, and operational parameters were examined to provide suggestions for optimal clinical use of the system., Research Design and Methods: Data from 31 adolescent and young adult participants (14-26 years old) at three clinical sites in the 670G pivotal trial were analyzed. Participants had a 2-week run-in period in OL, followed by a 3-month in-home study phase with HCL functionality enabled. Data were compared between baseline OL and HCL use after 1 week, 1 month, 2 months, and 3 months., Results: Carbohydrate-to-insulin (C-to-I) ratios were more aggressive for all meals with HCL compared with baseline OL. Total daily insulin dose and basal-to-bolus ratio did not change during the trial. Time in range increased 14% with use of Auto Mode after 3 months ( P < 0.001), and HbA
1c decreased 0.75%. Auto Mode exits were primarily due to sensor/insulin delivery alerts and hyperglycemia. The percentage of time in Auto Mode gradually declined from 87%, with a final use rate of 72% (-15%)., Conclusions: In transitioning young patients to the 670G system, providers should anticipate immediate C-to-I ratio adjustments while also assessing active insulin time. Users should anticipate occasional Auto Mode exits, which can be reduced by following system instructions and reliably bolusing for meals. Unique 670G system functionality requires ongoing clinical guidance and education from providers., (© 2018 by the American Diabetes Association.)- Published
- 2018
- Full Text
- View/download PDF
20. Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes.
- Author
-
Spaic T, Driscoll M, Raghinaru D, Buckingham BA, Wilson DM, Clinton P, Chase HP, Maahs DM, Forlenza GP, Jost E, Hramiak I, Paul T, Bequette BW, Cameron F, Beck RW, Kollman C, Lum JW, and Ly TT
- Subjects
- Adolescent, Adult, Blood Glucose metabolism, Blood Glucose Self-Monitoring, Double-Blind Method, Feasibility Studies, Female, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Male, Young Adult, Diabetes Mellitus, Type 1 drug therapy, Hyperglycemia drug therapy, Hypoglycemia drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
Objective: The objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control., Research Design and Methods: A 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15-45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70-180 mg/dL during the overnight period., Results: The addition of automated insulin delivery with PHHM increased the time spent in the target range (70-180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights ( P < 0.001). The average morning blood glucose concentration improved from 163 ± 23 mg/dL after PLGS nights to 142 ± 18 mg/dL after PHHM nights ( P < 0.001). Various sensor-measured hypoglycemic outcomes were similar on PLGS and PHHM nights. All participants completed 42 nights with no episodes of severe hypoglycemia, diabetic ketoacidosis, or other study- or device-related adverse events., Conclusions: The addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control., (© 2017 by the American Diabetes Association.)
- Published
- 2017
- Full Text
- View/download PDF
21. Refining the closed loop in the data age: research-to-practice transitions in diabetes technology.
- Author
-
Forlenza GP, Sankaranarayanan S, and Maahs DM
- Subjects
- Humans, Blood Glucose Self-Monitoring instrumentation, Diabetes Mellitus drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Published
- 2015
- Full Text
- View/download PDF
22. Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes
- Author
-
Brown SA, Kovatchev BP, Raghinaru D, Lum JW, Buckingham BA, Kudva YC, Laffel LM, Levy CJ, Pinsker JE, Wadwa RP, Dassau E, Doyle FJ, Anderson SM, Church MM, Dadlani V, Ekhlaspour L, Forlenza GP, Isganaitis E, Lam DW, Kollman C, Beck RW, Trial Research Group. iDCL, University of Virginia [Charlottesville], Department of Molecular Medicine [Tampa], University of South Florida [Tampa] (USF), Stanford School of Medicine [Stanford], Stanford Medicine, Stanford University-Stanford University, Mayo Clinic [Rochester], Harvard Medical School [Boston] (HMS), and Université de Lorraine (UL)
- Subjects
Adult ,Blood Glucose ,Male ,Pancreas, Artificial ,Pediatrics ,medicine.medical_specialty ,Adolescent ,Insulin delivery ,030204 cardiovascular system & hematology ,law.invention ,Young Adult ,03 medical and health sciences ,Insulin Infusion Systems ,0302 clinical medicine ,Randomized controlled trial ,law ,Diabetes mellitus ,Multicenter trial ,medicine ,Humans ,Hypoglycemic Agents ,Insulin ,MESH: Diabetes Mellitus, Type 1/drug therapy ,Hypoglycemic Agents/administration & dosage ,Insulin/administration & dosage ,Pancreas, Artificial/adverse effects ,In patient ,030212 general & internal medicine ,Aged ,Glycemic ,Glycated Hemoglobin ,Type 1 diabetes ,business.industry ,Equipment Design ,General Medicine ,Middle Aged ,[SDV.SP]Life Sciences [q-bio]/Pharmaceutical sciences ,medicine.disease ,3. Good health ,Diabetes Mellitus, Type 1 ,Multicenter study ,Female ,business ,[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology - Abstract
Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes.In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring.A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was70 mg per deciliter or54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group.In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).
- Published
- 2020