1. Outcomes and treatment strategy of transcatheter aortic valve replacement with balloon-expandable valve in borderline-size annulus.
- Author
-
Isogai T, Spilias N, Bakhtadze B, Sabbak N, Denby KJ, Layoun H, Agrawal A, Shekhar S, Yun JJ, Puri R, Harb SC, Reed GW, Krishnaswamy A, and Kapadia SR
- Subjects
- Humans, Female, Male, Retrospective Studies, Aged, 80 and over, Treatment Outcome, Aged, Risk Factors, Time Factors, Postoperative Complications etiology, Risk Assessment, Recovery of Function, Hemodynamics, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement instrumentation, Transcatheter Aortic Valve Replacement mortality, Heart Valve Prosthesis, Prosthesis Design, Aortic Valve diagnostic imaging, Aortic Valve surgery, Aortic Valve physiopathology, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Aortic Valve Stenosis mortality, Aortic Valve Stenosis physiopathology, Balloon Valvuloplasty adverse effects
- Abstract
Background: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited., Methods: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus., Results: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001)., Conclusion: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF