4 results on '"Kuntjoro I"'
Search Results
2. Meta-Analysis Comparing Risk Factors, Incidence, and Outcomes of Patients With Versus Without Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Implantation.
- Author
-
Lim OZH, Mai AS, Ng CH, Tang A, Chin YH, Kong G, Ho YJ, Ong J, Tay E, Kuntjoro I, Chew NW, and Lim Y
- Subjects
- Aged, Aortic Valve surgery, Humans, Incidence, Prosthesis Design, Risk Factors, Stroke Volume, Time Factors, Treatment Outcome, Ventricular Function, Left, Aortic Valve Stenosis, Heart Valve Prosthesis adverse effects, Heart Valve Prosthesis Implantation adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Current guidelines on the management of patients with aortic valvular disease have widened the use of transcatheter aortic valve implantation (TAVI) with an emphasis on avoidance of prosthesis-patient mismatch (PPM). This study sought to examine the incidence, risk factors, and all-cause mortality of PPM after TAVI. Medline and Embase databases were searched from inception to August 10, 2021. Patients were compared along 2 arms: (1) any degree of PPM and those without PPM, (2) severe PPM, and nonsevere PPM. A total of 22 articles involving 115,442 patients after TAVI were included. Pooled incidence for any degree of PPM was 30.1% and 10.7% in severe PPM. Incidence was significantly higher (p <0.001) for any degree of PPM in Europe (33.1%) and North America (34.4%) compared with Asia (10.4%). Incidence of severe PPM was higher (p = 0.015) in older generation (13.6%) compared with current-generation valves (6.3%). Severe PPM increased the risk of all-cause mortality relative to nonsevere PPM (hazard ratio: 1.86, 95% confidence interval: 1.05 to 3.29, p = 0.034). Patients of younger age, increased body surface area, lower left ventricular ejection fraction, and classified New York Heart Association Class III/IV were at greater risk of both any degree and severe PPM. Smaller prosthesis size increased the risk of any degree of PPM, whereas postdilation and larger prostheses were protective factors. In conclusion, all-cause mortality was significantly affected in severe PPM compared with nonsevere cases, whereas this excess mortality was not observed between those with any degree of PPM and those without. Closer attention to patient and bioprosthetic valve factors is required to minimize the occurrence of severe PPM., Competing Interests: Declaration of Competing Interest The authors have no conflicts of interest to declare., (Copyright © 2022 Elsevier Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
3. Outcome of Patients Undergoing Transcatheter Implantation of Aortic Valve With Previous Mitral Valve Prosthesis (OPTIMAL) Study.
- Author
-
Baldetti L, Giannini F, Van Mieghem N, El Faquir N, Tchétché D, De Biase C, Petronio AS, Giannini C, Tarantini G, Fraccaro C, Finkelstein A, Segev A, Barbash I, Bruschi G, Tamburino C, Barbanti M, Lim S, Kuntjoro I, Abdel-Wahab M, Colombo A, and Latib A
- Subjects
- Aged, Aged, 80 and over, Aortic Valve Stenosis surgery, Female, Follow-Up Studies, Heart Failure epidemiology, Humans, Male, Pacemaker, Artificial statistics & numerical data, Patient Readmission statistics & numerical data, Postoperative Complications epidemiology, Registries, Retrospective Studies, Heart Valve Prosthesis, Mitral Valve surgery, Transcatheter Aortic Valve Replacement
- Abstract
Background: Transcatheter aortic valve replacement (TAVR) is the gold standard for severe valvular aortic stenosis in patients at high/prohibitive surgical risk. This procedure has also been used in patients with previous mitral valve (MV) prostheses, with contrasting outcomes reported. The aim of this study is to describe procedural and early outcomes of patients with previous MV prostheses undergoing TAVR., Methods: This is a retrospective registry of 154 patients with previous MV prostheses who underwent TAVR across high-volume medical centres at a mean of 11.7 ± 8.4 years after mitral surgery., Results: Mean mitroaortic distance at computed tomography was 9.7 ± 4.8 mm. Procedural success was achieved in 150 (97.4%) patients, with reduction of aortic gradients (42.6 ± 14.2 to 10.0 ± 7.0 mm Hg; P < 0.001). Device success was achieved in 133 (86.3%) patients. MV prosthesis interference by the TAVR device was observed in 2 patients; in both, the mitroaortic distance was <5 mm, with 1 complicated by TAVR prosthesis embolization. Periprocedural complications included 4 (2.6%) cerebrovascular accidents, 10 (6.6%) major vascular complications, 22 (14.4%) severe bleedings, 1 (0.7%) myocardial infarction, and 5 (3.2%) in-hospital deaths (all cases cardiovascular or procedure related). At a median follow-up of 13.5 (interquartile range 1.0 to 36.0) months, 26 (16.9%) deaths occurred; 15 (9.7%) were cardiac related. Late fatal mitral prosthesis thromboses occurred in 2 patients. We recorded a case of fatal hemorrhagic stroke; hospital readmission was observed in 25 (16.2%) patients due to worsening heart failure., Conclusions: TAVR in patients with previous mitral prostheses appears to be safe and feasible, with good hemodynamic results at 30-day and at longer-term follow-up., (Copyright © 2019 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
4. 6-Minute walk test predicts prolonged hospitalization in patients undergoing transcatheter mitral valve repair by MitraClip.
- Author
-
Saji M, Katz MR, Ailawadi G, Welch TS, Fowler DE, Kennedy JLW, Bergin JD, Kuntjoro I, Dent JM, Ragosta M, and Lim DS
- Subjects
- Aged, Aged, 80 and over, Cardiac Catheterization adverse effects, Cardiac Catheterization methods, Female, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation methods, Humans, Male, Mitral Valve diagnostic imaging, Mitral Valve physiopathology, Mitral Valve Insufficiency diagnostic imaging, Mitral Valve Insufficiency physiopathology, Predictive Value of Tests, Prosthesis Design, Retrospective Studies, Risk Assessment, Risk Factors, Time Factors, Treatment Outcome, Cardiac Catheterization instrumentation, Exercise Tolerance, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Length of Stay, Mitral Valve surgery, Mitral Valve Insufficiency surgery, Walk Test
- Abstract
Background: The 6-minute walk test (6MWT) is a simple functional test that can predict exercise capacity and is widely employed to assess treatment outcomes. Although mortality with transcatheter mitral valve repair (TMVr) using the MitraClip (Abbott Vascular, Menlo Park, CA) is significantly less than for open mitral valve surgery in high-risk patients, identifying which patient will benefit the most from TMVr remains a concern. There are limited prognostic metrics guiding patient selection and, no studies have reported relationship between prolonged hospitalization and 6MWT. This study aimed to determine if the 6MWT can predict prolonged hospitalization in patients undergoing TMVr by MitraClip., Methods: We retrospectively reviewed 162 patients undergoing 6MWT before TMVr. Patients were divided into three groups according to the 6MWT distance (6MWTD) using the median (6MWTD ≥219 m, 6MWTD <219 m, and Unable to Walk). Multivariate logistic regression model was applied to select the demographic characteristics that were associated with the prolonged hospitalization defined as total length of stay ≥4 days in the study., Results: We found that 6MWT (odds ratio 3.64, 95% confidence interval 2.03-6.52, P < 0.001) was independently associated with prolonged hospitalization after adjustment in multivariate analysis. Area under the curve of 6MWT for predicting prolonged hospitalization was 0.79 (95% confidence interval 0.72-0.85)., Conclusions: Our study demonstrates that 6MWT was independently associated with prolonged hospitalization in patients with TMVr, and has a good discriminatory performance for predicting prolonged hospitalization., (© 2018 Wiley Periodicals, Inc.)
- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.