1. Continuous glucose monitoring in patients with type 2 diabetes on hemodialysis
- Author
-
Maurizio Gallieni, Francesca D'Addio, Antonio Rossi, Gianmarco Sabiu, Paolo Fiorina, Gian Vincenzo Zuccotti, Cristina De Salvo, Roberta Miglio, Ida Pastore, and Maria Elena Lunati
- Subjects
Blood Glucose ,Glycation End Products, Advanced ,Male ,medicine.medical_specialty ,Endocrinology, Diabetes and Metabolism ,medicine.medical_treatment ,030232 urology & nephrology ,030209 endocrinology & metabolism ,Review Article ,Glycemic Control ,Disease ,Type 2 diabetes ,03 medical and health sciences ,chemistry.chemical_compound ,Diabetes mellitus ,0302 clinical medicine ,Endocrinology ,Renal Dialysis ,Chronic kidney disease ,Internal medicine ,Internal Medicine ,medicine ,Humans ,Diabetic Nephropathies ,Glycated Serum Albumin ,Continuous glucose monitoring ,Serum Albumin ,Aged ,Glycemic ,Glycated Hemoglobin ,business.industry ,Blood Glucose Self-Monitoring ,General Medicine ,Middle Aged ,medicine.disease ,Fructosamine ,Diabetes Mellitus, Type 2 ,chemistry ,Hemodialysis ,Kidney Failure, Chronic ,Female ,Glycated hemoglobin ,business ,Biomarkers ,Kidney disease - Abstract
Diabetic kidney disease is the leading cause of end-stage kidney disease in high-income countries. The strict control of glycemic oscillations is the principal therapeutic target, but this could be hard to achieve in uremic patients due to their unpredictable insulin sensitivity. Currently, the evaluation of the glycemic profile relies on serum markers (glycated hemoglobin HbA1c, glycated albumin, and fructosamine), capillary glucose blood control (self-monitoring of blood glucose), and interstitial glucose control (continue glucose monitoring). We conducted a systematic review of published articles on continue glucose monitoring in hemodialysis patients with type 2 diabetes, which included 12 major articles. Four studies found significant fluctuations in glucose levels during hemodialysis sessions. All studies reported a higher mean amplitude of glucose variations on the hemodialysis day. Three studies agreed that continue glucose monitoring is better than glycated hemoglobin in detecting these abnormalities. Moreover, continue glucose monitoring was more accurate and perceived as easier to use by patients and their caregivers. In patients with type 2 diabetes on hemodialysis, glucose levels show different variation patterns than the patients on hemodialysis without diabetes. Considering manageability, accuracy, and cost-effectiveness, continue glucose monitoring could be the ideal diagnostic tool for the patient with diabetes on hemodialysis.
- Published
- 2021
- Full Text
- View/download PDF