14 results on '"Fallos"'
Search Results
2. Defectos frecuentes en la instalación de capas de impermeabilización en terrazas de azoteas = Frequent flaws in the installation of waterproofing layers in roof terraces
- Author
-
Miguel Gómez Chaparro, Gonzalo Sánchez Barroso, Manuel J. Carretero Ayuso, and Justo García Sanz-Calcedo
- Subjects
fallos ,edificios ,cubiertas ,mantenimiento ,failures ,buildings ,decks ,maintenance ,Technology ,Building construction ,TH1-9745 - Abstract
Las cubiertas son la parte más vulnerable de un edificio porque que están expuestas continuamente a las acciones climáticas externas y a su constante variabilidad, ya sea en lo relacionado con la lluvia, nieve, viento, temperatura, agentes biológicos o radiación solar. Por esta razón, dado su gran exposición a todos estos factores, los fallos que pudieran existir en una pequeña área de cubierta son, en la mayoría situaciones, más serios que en otros lugares, dado la velocidad de avance que tienen, así como su repercusión en la habitabilidad. Hace algunos años, una investigación realizada en Australia (en el estado de Victoria) determinó que las cubiertas son el segundo elemento de construcción más afectado por el número de fallos en ese país. En España, las cubiertas son también el segundo capítulo de obra más afectado por patologías, según un estudio de investigación sobre reclamaciones de usuarios. Para averiguar qué irregularidades y mala praxis constructiva se comete durante la ejecución (especialmente filtraciones y humedades, se ha querido analizar cuáles son los fallos más frecuentes en la instalación en obra de la impermeabilización. Para proceder a estudiar los fallos durante la ejecución ha sido necesario recurrir a algún tipo de fuente escrita que pudiera contener esta información. Hay que tener en cuenta que las constructoras en España, salvo casos muy excepcionales, no llevan un registro por escrito de cada una de las deficiencias de puesta en obra o de los incumplimientos normativos que acontezcan. Por tanto, hay que recurrir a las anotaciones que hace la dirección facultativa en el ‘libro de órdenes y visitas’. La investigación llevada a cabo se ha realizado en obras de la provincia de Badajoz, todas de tipo residencial entre 2012 y 2018, sobre las que se ha constatado cuáles son los fallos más frecuentes, haciendo un estudio comparativo entre las promociones que eran de viviendas unifamiliares y las que eran de viviendas en bloque. De esta manera, se pudo constatar que había 10 tipos de fallos que se daban en más del 30% de las ocasiones estudiadas. Especialmente reseñables son los fallos denominados ‘La altura de coronación de la impermeabilización es menor a lo que indica el CTE’ y ‘La cota del umbral está por debajo del nivel de protección de la cubierta’ que tuvieron una presencia superior al 75% de los casos. Abstract The roofs are the most vulnerable part of the building because they are continually exposed to external climatic actions and their constant variability, whether related to rain, snow, wind, temperature, biological agents or solar radiation. For this reason, given their great exposure to all these factors, the faults that may exist in a small cover area are, in most situations, more serious than in other places given the speed of progress they have, as well as their impact on habitability. A few years ago, an investigation carried out in Australia (in the state of Victoria) determined that the roofs are the second building element most affected by the number of failures in that country. In Spain, the covers are also the second chapter of work most affected by pathologies, according to a research study on user complaints. To find out what irregularities and constructive malpractice are committed during the execution (especially filtrations and dampness, it has been wanted to analyze specifically are the most frequent failures in the installation in waterproofing work. To proceed to study the errors during the execution it has been necessary to resort to some type of written source that may contain this information. It must be borne in mind that construction companies in Spain, except for very exceptional cases, do not keep a written record of each of the deficiencies in the implementation or the regulatory breaches that occur. Therefore, the annotations made by the optional address in the "book of orders and visits" must be repeated. The investigation carried out has been carried out in works of the province of Badajoz, all of residential type between 2012 and 2018, on which frequent failures have been found, making a comparative study between the promotions that were of single-family homes and those of block houses. In this way, it was found that there were 10 types of failures that occurred in more than 30% of the studied occasions. Especially noteworthy are the failures called 'The crowning height of the waterproofing is less than what the CTE indicates' and 'The threshold level is below the level of protection of the roof' that had a presence greater than 75% of the cases.
- Published
- 2019
- Full Text
- View/download PDF
3. Effects of the earthquake of September 19, 2017, in homes, in the municipality of Chietla, Puebla.
- Author
-
VÁZQUEZ-TORRES, María del Rayo, CASTILLO-REYES, Alberto Rosendo, MORALES-ORTEGA, José Alejandro, and MONTERO-URRUSQUIETA, Rubén Ángel
- Subjects
- *
EARTHQUAKES , *MUNICIPAL government , *LATITUDE , *SEISMIC response , *FIELD research - Abstract
This work aims to publicize the effects of the 2017 earthquake on homes in the municipality of Chietla, Puebla, epicenter of the earthquake. The fieldwork was carried out by teachers and students of the Faculty of Architecture of the Benemérita Universidad Autónoma de Puebla, to support the community with a damage survey. To carry out the work, a report sheet was used where the data from the survey sheet were processed, determining the seismic analysis, the state of the construction was verified. The working groups were composed of a teacher and four students who visited each house, where images were taken, the location by latitude and longitude coordinates and the data collection. Subsequently, the information was gathered and a report was made to Civil Protection ranking the degrees of affectation. This work is the result of this field research divided into three sections. In the first part, the concepts involved in the topic are defined; the second part describes the geographical location and characteristics of Chietla; finally, the third part identifies the most common faults found in the fieldwork. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
4. Determinación de las Prioridades de Mantenimiento en Turbogeneradores 'Elektrosila TBФ-100-3600-T3' a partir del Comportamiento de sus Fallos; Determination of Maintenance Priorities in Turbogenerators 'Elektrosila TBФ- 100-3600-T3' Based on their Failure
- Author
-
Odalys Martínez Rodríguez and Santiago Alfredo Dorrbercker Drake
- Subjects
análisis de criticidad ,análisis sistémico ,fallos ,turbogeneradores ,analysis of criticality ,systemic analysis ,failures ,turbogenerators. ,Electrical engineering. Electronics. Nuclear engineering ,TK1-9971 ,Production of electric energy or power. Powerplants. Central stations ,TK1001-1841 - Abstract
Los generadores de potencia son de gran importancia para la producción de electricidad. Un fallo en un generador ocasiona la interrupción de su servicio, limitaciones o pérdida total de la energía generada, tiene efectos negativos sobre la economía y afecta la calidad de la vida de la sociedad. Ello conduce a la necesidad un control estricto de los generadores y sus sistemas, tal que faciliten la detección temprana de desviaciones en sus parámetros de operación e intervenir apropiadamente para impedir la ocurrencia de una avería. Este trabajo tiene como objetivo presentar los resultados de tres variantes empleadas en la determinación de las prioridades de mantenimiento de los turbogeneradores “ELEKTROSILA TBФ-100-3600-T3”, las variantes estudiadas fueron: el comportamiento histórico de los fallos, el comportamiento histórico de la energía indisponible debido a los fallos y el análisis de criticidad; los resultados, sustentados en seis años de estudio, descartaron la utilización del criterio de energía indisponible. The power generators are very important for the electricity production. A failure in a generator causes the interruption of service, limitations or the complete loss of the generated energy, has negative effects on theeconomy and it harms quality of life of the society. This leads to the necessity of a strict control of the generators as in their systems, such that facilitates the early detection of any deviation on their operationparameters to intervene appropriately and avoid the occurrence of a failure. This paper has the objective to present the results of three variants used in the determination of the priorities of maintenance of theturbogenerators "ELEKTROSILA TBФ-100-3600-T3", the analyzed variants were: the historical behavior of failures, the historical behavior of the unavailable energy due to failures and the analysis of criticality; theobtained results, supported in six years of study, discard the use unavailable energy criteria.
- Published
- 2012
5. Backtesting crypto market investment algorithms
- Author
-
Arnal García, David
- Subjects
Rendimiento ,Performance ,Grado en Ingeniería Informática-Grau en Enginyeria Informàtica ,Estrategias de trading ,HDF5 ,Pandas ,Algoritmo NSGA-2 ,Failures ,NSGA-2 algorithm ,Decisions de trading ,Backtesting ,Optimización ,ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES ,Estratègies de trading ,Trading decisions ,Traders ,Decisiones de trading ,Rendiment ,Trading strategies ,Optimisation ,Fallos ,Algorisme NSGA-2 ,Optimització ,Fallades - Abstract
[CA] A l'hora de desenvolupar una estratègia de trading, és essencial provar com hauria funcionat en el passat. Això permet estimar el seu potencial rendiment i trobar els millors paràmetres. Cal tenir un sistema que collecte, emmagatzeme i organitze les dades abans de començar el backtesting. Aquestes dades es faran servir per a calcular el rendiment de l'estratègia. En aquest document s'ensenyarà sobre HDF5. HDF5 és un poderós format de fitxer que pot emmagatzemar dades de veles japoneses de manera eficient. Molts desenvolupadors no coneixen aquest format de fitxer, per la qual cosa aprendre'l comporta obtenir un avantatge competitiu davant els altres desenvolupadors. Es pot utilitzar la programació per fer el backtest de l'estratègia. Per exemple, es pot fer servir la biblioteca anomenada pandas per calcular indicadors tècnics, i també es pot fer servir un algorisme d'optimització per trobar els millors paràmetres per a l'estratègia. NSGA-2 és una gran opció per a aquest propòsit, i en aquest document es parlarà sobre com implementar-ho. Aquest enfocament és únic i ajudarà a treure el màxim profit del backtesting. El backtesting és una eina essencial que tot trader hauria de fer ús per millorar la seua estratègia de trading, ja que pot ajudar a identificar errors en l'estratègia i fer millores amb decisions de trading més informades., [ES] A la hora de desarrollar una estrategia de trading, es esencial probar cómo habría funcionado en el pasado. Esto permite estimar su potencial rendimiento y encontrar los mejores parámetros. Es necesario tener un sistema que recoja, almacene y organice los datos antes de empezar el backtesting. Estos datos se utilizarán para calcular el rendimiento de la estrategia. En este documento, se enseñará sobre HDF5. HDF5 es un poderoso formato de archivo que puede almacenar datos de velas japonesas de manera eficiente. Muchos desarrolladores no conocen este formato de archivo, por lo que aprenderlo conlleva obtener una ventaja competitiva ante los demás desarrolladores. Se puede usar la programación para realizar el backtest de la estrategia. Por ejemplo, la biblioteca llamada pandas puede ser útil para calcular indicadores técnicos, y también se puede ejecutar un algoritmo de optimización para encontrar los mejores parámetros para la estrategia. NSGA-2 es una gran opción para este propósito, y en este documento se hablará sobre cómo implementarlo. Este enfoque es único y ayudará a sacar el máximo provecho del backtesting. El backtesting es una herramienta esencial que todo trader debería tener en cuenta para mejorar su estrategia de trading, ya que puede ayudar a identificar fallos en la estrategia y a conseguir mejoras con decisiones de trading más informadas., [EN] When developing a trading strategy, it is essential to test how it would have worked in the past. It allows to estimate its potential performance and find the best parameters for it. It is needed to have a system that collects, stores, and organizes data before the backtesting starts. This data will calculate the strategy's performance, and HDF5 is the file format that will store the data. HDF5 is a powerful file format that can store candlestick data efficiently. Many developers do not know about this file format, so learning it will give them a competitive advantage. Programming is the tool to backtest the strategies. For example, the library pandas can calculate technical indicators, and an optimization algorithm can find the best parameters for the strategy. NSGA-2 is an excellent option for this purpose, and this paper will show how to implement it. This unique approach will help get the most out of the backtesting. Backtesting is an essential tool every trader should use to improve their trading strategy because it can help traders identify flaws in their strategy and make improvements with more informed trading decisions.
- Published
- 2022
6. Defectos frecuentes en la instalación de capas de impermeabilización en terrazas de azoteas = Frequent flaws in the installation of waterproofing layers in roof terraces
- Author
-
Gonzalo Sánchez Barroso, Manuel Jesús Carretero Ayuso, Justo García Sanz-Calcedo, and Miguel Gómez Chaparro
- Subjects
lcsh:T ,General Arts and Humanities ,media_common.quotation_subject ,Fallos ,edificios ,cubiertas ,mantenimiento ,Failures ,buildings ,decks ,maintenance ,fallos ,failures ,Art ,lcsh:Technology ,lcsh:TH1-9745 ,Humanities ,media_common ,lcsh:Building construction - Abstract
Las cubiertas son la parte mas vulnerable de un edificio porque que estan expuestas continuamente a las acciones climaticas externas y a su constante variabilidad, ya sea en lo relacionado con la lluvia, nieve, viento, temperatura, agentes biologicos o radiacion solar. Por esta razon, dado su gran exposicion a todos estos factores, los fallos que pudieran existir en una pequena area de cubierta son, en la mayoria situaciones, mas serios que en otros lugares, dado la velocidad de avance que tienen, asi como su repercusion en la habitabilidad. Hace algunos anos, una investigacion realizada en Australia (en el estado de Victoria) determino que las cubiertas son el segundo elemento de construccion mas afectado por el numero de fallos en ese pais. En Espana, las cubiertas son tambien el segundo capitulo de obra mas afectado por patologias, segun un estudio de investigacion sobre reclamaciones de usuarios. Para averiguar que irregularidades y mala praxis constructiva se comete durante la ejecucion (especialmente filtraciones y humedades, se ha querido analizar cuales son los fallos mas frecuentes en la instalacion en obra de la impermeabilizacion. Para proceder a estudiar los fallos durante la ejecucion ha sido necesario recurrir a algun tipo de fuente escrita que pudiera contener esta informacion. Hay que tener en cuenta que las constructoras en Espana, salvo casos muy excepcionales, no llevan un registro por escrito de cada una de las deficiencias de puesta en obra o de los incumplimientos normativos que acontezcan. Por tanto, hay que recurrir a las anotaciones que hace la direccion facultativa en el ‘libro de ordenes y visitas’. La investigacion llevada a cabo se ha realizado en obras de la provincia de Badajoz, todas de tipo residencial entre 2012 y 2018, sobre las que se ha constatado cuales son los fallos mas frecuentes, haciendo un estudio comparativo entre las promociones que eran de viviendas unifamiliares y las que eran de viviendas en bloque. De esta manera, se pudo constatar que habia 10 tipos de fallos que se daban en mas del 30% de las ocasiones estudiadas. Especialmente resenables son los fallos denominados ‘La altura de coronacion de la impermeabilizacion es menor a lo que indica el CTE’ y ‘La cota del umbral esta por debajo del nivel de proteccion de la cubierta’ que tuvieron una presencia superior al 75% de los casos. Abstract The roofs are the most vulnerable part of the building because they are continually exposed to external climatic actions and their constant variability, whether related to rain, snow, wind, temperature, biological agents or solar radiation. For this reason, given their great exposure to all these factors, the faults that may exist in a small cover area are, in most situations, more serious than in other places given the speed of progress they have, as well as their impact on habitability. A few years ago, an investigation carried out in Australia (in the state of Victoria) determined that the roofs are the second building element most affected by the number of failures in that country. In Spain, the covers are also the second chapter of work most affected by pathologies, according to a research study on user complaints. To find out what irregularities and constructive malpractice are committed during the execution (especially filtrations and dampness, it has been wanted to analyze specifically are the most frequent failures in the installation in waterproofing work. To proceed to study the errors during the execution it has been necessary to resort to some type of written source that may contain this information. It must be borne in mind that construction companies in Spain, except for very exceptional cases, do not keep a written record of each of the deficiencies in the implementation or the regulatory breaches that occur. Therefore, the annotations made by the optional address in the "book of orders and visits" must be repeated. The investigation carried out has been carried out in works of the province of Badajoz, all of residential type between 2012 and 2018, on which frequent failures have been found, making a comparative study between the promotions that were of single-family homes and those of block houses. In this way, it was found that there were 10 types of failures that occurred in more than 30% of the studied occasions. Especially noteworthy are the failures called 'The crowning height of the waterproofing is less than what the CTE indicates' and 'The threshold level is below the level of protection of the roof' that had a presence greater than 75% of the cases.
- Published
- 2019
- Full Text
- View/download PDF
7. Estudio del riesgo de explosión e incendio en una unidad de destilación de crudo de una refinería de petróleo
- Author
-
Mendieta Rodríguez, Andrea
- Subjects
Grado en Ingeniería Química-Grau en Enginyeria Química ,Explosión ,Explosion ,Hidrocarburos ,Congested area ,Failures ,Sustancias peligrosas ,Incendio ,Fire ,Hydrocarbons ,INGENIERIA QUIMICA ,Área congestionada ,Scenarios ,Escenarios ,Fallos ,Hazardous substances - Abstract
[ES] El tema propuesto para el Trabajo Final de Grado surge a partir de la realización de prácticas en una empresa de consultoría especializada en seguridad de procesos. La empresa asesora a sus clientes evaluando los riesgos del proceso y desarrollando soluciones prácticas. Recientemente un cliente dedicado a la industria del petróleo y del gas natural ha decidido desarrollar un proyecto de construcción de una nueva refinería de base integrada y un complejo petroquímico con todas sus instalaciones asociadas. Las compañías que trabajan en este sector presentan un alto riesgo de incendio y explosión debido a las propiedades de las sustancias que intervienen en los distintos procesos. Por esta razón, la empresa ha encargado la realización de un estudio específico para evaluar las consecuencias de posibles incendios y explosiones producidos en las nuevas instalaciones que podrían afectar a los elementos vulnerables situados alrededor de la nueva planta, como por ejemplo edificios ocupados y núcleos poblados. Para la realización del proyecto se va a llevar a cabo un FEA (Fire and Explosion Consequence Assessment) con la finalidad de evaluar las consecuencias (en términos de radiación térmica y sobrepresión) de posibles accidentes en la unidad inicial de la refinería cuyo objetivo es la destilación del crudo en diversas fracciones para su posterior procesamiento. En primer lugar, se identifican las secciones aislables más representativas del proceso en las cuales se utilizan sustancias peligrosas capaces de dañar personas, edificios y equipos debido a sus propiedades inflamables. Posteriormente se identificarán los posibles casos de fallo (genéricos y específicos) de los equipos relacionados y se analizarán las consecuencias asociadas a cada caso de fallo. El análisis de consecuencias se lleva a cabo mediante la simulación de cada evento iniciador desde la pérdida de contención hasta todas las posibles evoluciones con la ayuda de un software (PHAST) que trabaja bajo las condiciones de funcionamiento del proceso. En el presente Trabajo de Final de Grado se describe el proceso que se ha seguido para identificar y posteriormente analizar las consecuencias de posibles accidentes de proceso que podrían ocurrir en la unidad de separación de crudo y para proponer las medidas de seguridad (preventivas y/o atenuantes) necesarias para proteger la población y los trabajadores que ocupan los edificios de la nueva planta. Finalmente se realizará una valoración económica del proyecto., [EN] The theme proposed for the Final Degree Project arises from the realization of an internship in a company dedicated to process safety. The company advises its clients by assessing risks and developing practical solutions. Recently, a client dedicated to the oil and natural gas industry has decided to develop a construction project for a new integrated base refinery and a petrochemical complex with all its associated facilities. The companies that work in this sector present a high risk of fire and explosion due to the properties of the substances that intervene in the different processes. For this reason, the company has commissioned a specific study to assess the consequences of possible fires and explosions produced in the new facilities that could affect the vulnerable elements located around the new plant, such as occupied buildings and populated areas. In order to carry out the project, a FEA (Fire and Explosion Consequence Assessment) will be accomplished in order to evaluate the consequences (in terms of thermal radiation and overpressure) of possible accidents in the initial refinery unit whose objective is the distillation of crude oil into various fractions for further processing. First, the most representative isolatable sections of the process are identified in which hazardous substances capable of damaging people, buildings and equipment due to their flammable properties are used. Then, the possible failure cases (generic and specific) of the related equipment will be identified and the consequences associated with each failure case will be analysed. The consequence analysis is carried out by simulating each initiating event from the loss of containment to all possible evolutions with the help of software (PHAST) that works under the operating conditions of the process. This Final Degree Project describes the process that has been followed to identify and later analyse the consequences of possible process accidents that could occur in the crude oil separation unit and to proposes the safety measures (preventive and / or extenuating factors) necessary to protect the population and workers occupying the buildings of the new plant. Finally, an economic evaluation of the project will be executed.
- Published
- 2021
8. Failures in the regulation of the Colombian state in the management of the public electricity service in Colombia: Electricaribe case 2002-2019
- Author
-
Rodríguez Rodríguez, Monica Natalia and Agudelo Velásquez, Leidy Johana
- Subjects
Electricaribe ,servicio de energía eléctrica ,usuarios ,Failures ,SERVICIOS PUBLICOS ,National Government ,SISTEMAS DE ENERGIA ELECTRICA ,electric power service ,Costa Caribe ,users ,Fallos ,Caribbean Coast ,Gobierno nacional - Abstract
Para el desarrollo del presente ensayo, se tomará como caso de estudio la empresa prestadora del servicio eléctrico en la región caribe del país Electricaribe S.A y los diferentes estatutos y posiciones que el Gobierno Nacional ha presentado frente a la privatización de las empresas públicas del Estado y la prestación eficiente del servicio. Inicialmente, se encontró que el Estado colombiano no ha realizado de la mejor manera la vigilancia, control y regulación a la empresa prestadora del servicio eléctrico Electricaribe, por tanto, el país tendría un impacto económico por un valor que supera los $2,2 billones; de los cuales corresponden al pasivo pensional y prestacional con corte de diciembre de 2018 por un valor de $1,1 billones, y $1,12 billones es el valor de la deuda de Electricaribe a septiembre de 2019, estas cifras varían de acuerdo al IPC y el visto final lo da el CONPES.( Portafolio, 2019). Según el PND 2018-2022, el gobierno aprobó un artículo en el cual de manera directa o indirecta se haría cargo de este saldo que dejó Electricaribe, por lo cual, analizando estas decisiones, se realizará el análisis de los principales fallos por parte de los últimos 3 Gobiernos nacionales frente a la crisis eléctrica presentada por la empresa Electricaribe. Tabla de contenido Introducción 1 Pregunta problema 4 Objetivo general 4 Objetivos específicos 4 Marco teórico 5 Conclusiones 18 Bibliografía 20 For the development of this essay, the electricity service provider company in the Caribbean region of the country Electricaribe SA and the different statutes and positions that the National Government has presented in the face of the privatization of the State public companies will be taken as a case study. The efficient provision of the service. Initially, it was found that the Colombian State has not carried out in the best way the surveillance, control and regulation of the electricity service provider Electricaribe, therefore, the country would have an economic impact for a value that exceeds $ 2.2 billion; of which correspond to the pension and benefit liability with a December 2018 cutoff for a value of $ 1.1 trillion, and $ 1.12 trillion is the value of Electricaribe's debt as of September 2019, these figures vary according to the CPI and the final check is given by CONPES (Portfolio, 2019). According to the PND 2018-2022, the government approved an article in which it would directly or indirectly take charge of this balance left by Electricaribe, for which, by analyzing these decisions, an analysis of the main failures by the authorities will be carried out. Last 3 national governments in the face of the electricity crisis presented by the Electricaribe company. Especialización
- Published
- 2021
9. Los Fallos del Mercado y la Intervención Pública: Una Visión desde la Perspectiva de la Elección Pública en el Ecuador, Periodo 2010-2018
- Author
-
Rizzo-Guambaña, Gabriel and Camacho-Estrada, Eugenia
- Subjects
Juicios ,Failures ,Leyes ,Laws ,Market ,Social policy ,Política social ,Elección ,Choice ,Judgements ,Mercado ,Perspectivas ,Fallos ,Perspectives - Abstract
Diversity of thoughts related to theoretical knowledge and economic political practices; discoveries in the field of economic analysis; the intervention of new technologies; statistics; and, new techniques for monitoring economies, have not succeeded in removing discrepancies; there are now major market failures. The rulers in Ecuador, were and are chosen by sympathy, most voters do not analyze the plan of government that each voter must submit during their candidacy and the beginning of the first year of management. On the other hand, the continuous change of ideologies, initiating when the state should not intervene in the market assuming that things would improve on their own (Neoliberal politics); and then, when the state decides to intervene in the market, creating an artificial economy (neo-Keynesian politics). This study was based on documentary-based analytical research, using inductive, analytical and synthesis research methods. Concluding that there is no defined policy in Ecuador, which we would say applies to it as appropriate as the nominated authorities. La diversidad de pensamientos relacionados con el saber teórico y las prácticas políticas económicas, los descubrimientos en el campo del análisis económico, la intervención de la nuevas tecnologías, la estadística, y las nuevas técnicas para seguimiento de las economías, no han lograron que las discrepancias se eliminen; en la actualidad existen grandes fallos en el mercado. Los gobernantes en Ecuador fueron y son elegidos por simpatía, la mayoría de los votantes no analizan el plan de gobierno que cada elector debe presentar durante su candidatura e inicio del primer año de gestión. Por otro lado, el continuo cambio de ideologías, iniciando cuando el Estado no debe intervenir en el mercado suponiendo que las cosas se mejorarían por sí solas (política neoliberal); y posteriormente, cuando el Estado decide intervenir en el mercado, creando una economía artificial (política neokeynesiana). Este estudio se fundamentó en una investigación analítica de base documental, usamos como método de investigación el inductivo, analítico y de síntesis. Obteniendo como conclusión que en el Ecuador no se observa una política definida, lo que diríamos que esta se aplica según la conveniencia de las autoridades nominadas.
- Published
- 2020
10. Fallos en el filtraje de información auditiva en esquizofrenia: ¿disfunción de cortezas uni o heteromodales?
- Author
-
Paz, R. D., Ortiz, T., and Cañive, J. M.
- Subjects
- *
AUDITORY evoked response , *SCHIZOPHRENIA , *COGNITION disorders , *PREFRONTAL cortex , *MAGNETOENCEPHALOGRAPHY , *ELECTROENCEPHALOGRAPHY - Abstract
Failure filtering out redundant auditory information is the most replicated neurophysiological abnormality observed in patients with schizophrenia. However, the brain structures involved in this deficit remains obscure. Two main hypotheses have been proposed to explain this phenomenon. The first maintains that the auditory gating deficit in schizophrenia is related to abnormal function of microcircuits within the hippocampal formation. The second hypothesis proposes that the deficit may be linked to impaired prefrontal cortex function. In both scenarios, auditory gating is conceptualized as a process dependent on the functional indemnity of cortical areas that integrate information from different sensory modalities. When filtering out redundant information, heteromodal cortices (hippocampal formation or prefrontal cortex), ensure that redundant stimuli do not reach higher-order levels of information processing in the brain and do not interfere with working memory performance. Findings from our lab, using magnetoencephalography (MEG), and data from other labs using electroencephalography (EEG), suggest an alternative hypothesis. We hypothesize that auditory gating deficit in schizophrenia is due to the abnormal function of unimodal microcircuits within left auditory cortex, independent from abnormalities in heteromodal cortices. Explaining whether auditory gating deficit in schizophrenia is determined by a primary dysfunction of unimodal or multimodal cortices may help elucidate the mechanisms involved in the sensory information overload and the characteristic cognitive deficits found in this disorder. [ABSTRACT FROM AUTHOR]
- Published
- 2007
11. Diseño de un mobiliario innovador para el revelado fotográfico
- Author
-
Fernández Espinosa, María Victoria
- Subjects
Diseño ,Design ,Aesthetics ,Rendimiento ,Performance ,Improvements ,Failures ,Mejoras ,Market ,Ergonomic ,Estética ,Mercado ,Ergonomía ,Grado en Ingeniería en Diseño Industrial y Desarrollo de Productos-Grau en Enginyeria en Disseny Industrial i Desenvolupament de Productes ,Fallos ,PROYECTOS DE INGENIERIA ,Fotografía - Abstract
[ES] Tras la valoración de las distintas alternativas, se ha determinado una propuestas óptima a partir de dos modelos ideados. Posteriormente, se ha realizado una descripción detallada de la solución, teniendo en cuenta factores como los materiales, las necesidades para la obtención del revelado de las fotografías, la resistencia estructural del producto, los procesos industriales necesarios para su fabricación y el embalaje., [EN] This project aims to design and develop a furniture for the reveal of photographs. After evaluating the different alternatives, an optimal proposal has been determined from two models devised. Subsequently, it has been a detailed description of the solution, taking into account factors such as materials, the needs for obtaining the development of photographs, the structural strength of the product, the industrial processes necessary for its manufacture and packaging.
- Published
- 2019
12. Planificación y estructuración de sistema de gestión de la calidad para la empresa metálicas Juven S.A.S bajo los lineamientos de la norma NTC ISO 9001:2015
- Author
-
López Velásquez, Melissa, Cepeda Sarmiento, Oscar Leonardo, Venegas Franco, Andrea, Velásquez Velasco, Lina María, and Martinez Ramos, Germán Arturo
- Subjects
Sistemas de gestión ,quality ,calidad ,fallos ,quality management system ,failures ,procedimientos ,sistema de gestión de calidad ,sobrecostos ,Procedures ,metalmecanica ,metalworking ,cost overruns - Abstract
Se presenta en el siguiente proyecto la planificación y estructuración del Sistema de Gestión de Calidad se ddesarrollado en la organización METÁLICAS JUVEN S.A.S. S.A.S ubicada en el municipio de Soacha Cundinamarca, bajo la NTC ISO 9001:2015. Se implementan acciones debido a la ausencia de procedimientos o información documentada para realizar sus actividades, sus procesos no se encuentran estandarizados, se identifican problemas de señalización, calibración y mantenimiento de equipos, carece de cultura de almacenamiento y correcto uso de herramientas y materiales, aumentando los sobrecostos por fallos, medidas defectuosas, errores en el diseño, fabricación, distribución, venta y montaje de estructuras metálicas, además de brindar una imagen al cliente de congestión en sus procesos e instalaciones. Con el fin de estructurar el sistema de gestión de calidad y evidenciar el aumento de satisfacción de sus clientes. The planning and structuring of the Quality Management System is presented in the following project in the organization METÁLICAS JUVEN S.A.S. SA in the municipality of Soacha Cundinamarca, under the NTC ISO 9001: 2015. Actions are implemented as explained by the absence of technical information. The cost overruns for failures, defective measurements, errors in the design, manufacture, distribution, sale and assembly of metal structures, as well as providing an image to the customer of congestion in their processes and facilities. In order to structure the quality management system and demonstrate the increase in customer satisfaction. http://unidadinvestigacion.usta.edu.co Especialización
- Published
- 2019
13. Práctica empresarial como auxiliar de ingeniería civil apoyando labores de supervisión y control en el proyecto de pavimento urbano en el municipio de Aguachica- Cesar
- Author
-
Delgado Rocha , Daniela and Rondón Ordoñez, Jaime
- Subjects
Platforms ,Court Minutes ,Failures ,Pavimento ,Supervision ,Andenes ,Sewerage ,Cantidades De Obra ,Amounts Of Works ,Unit Prices ,Pavement ,Alcantarillado ,Control ,Unforessen ,Imprevistos ,Precios Unitarios ,Actas De Corte ,Fallos - Abstract
126 p., In the following degree project will be announced all the activities developed in the city of Aguachica, Cesar, the experiences obtained in the field as civil engineer and the knowledge acquired during the stay in the university that was of great help to provide keys to the company LUIS ALEJANDRO GONZÁLEZ Y LA GOBERNACIÓN DEL CESAR, with the objective of developing this great project and improving the quality of life of the inhabitants within five months. The business practice that was developed was related to urbanism works of the LA UNIÓN neighborhood of the city of Aguachica, Cesar, performing field work in the supervision and control of the execution of rigid pavement of 4200 PSI also verifying the characteristics of finishes (texture), platforms that were a requirement of the supervision and installation of sewer pipes; control in the reception, supply and dispatch of materials that were needed; verification of failures in the field and contingencies providing technical criteria to solve all the problems presented where the opportunity was given to investigate and apply the knowledge acquired in the academic training provided by the university. In relation to office work, work quantities were calculated, unit prices were updated, and court minutes were drawn up. To conclude, with the activities carried out in this internship all doubts were clarified in some concepts, new knowledge was learned and something worth mentioning is the acquisition of the habit to make decisions, present initiatives in the problems or difficulties presented in the development From this project. All values were corroborated, principles such as responsibility, compliance that a civil engineer must to have., En el siguiente proyecto de trabajo de grado se dará a conocer todas las actividades desarrolladas en el municipio de Aguachica – Cesar, las experiencias vividas en el campo como Ingeniera Civil y el conocimiento adquirido en la universidad fue de gran ayuda para aportar a la empresa LUIS ALEJANDRO GONZALEZ HERNANDEZ y LA GOBERNACIÓN DEL CESAR, con el fin de desarrollar este gran proyecto y de esta manera apoyar a la comunidad para mejorar la calidad de vida de los habitantes de este sector, durante un periodo aproximadamente de 5 meses. La práctica empresarial que se desarrolló fue relacionada con obras de urbanismo del Barrio LA UNIÓN del Municipio de Aguachica – Cesar, realizando labores de campo en la supervisión y control en la ejecución de pavimento rígido de 4200 PSI verificando también las características de acabados (textura), andenes que era una exigencia de la interventoría e instalación de tubería de alcantarillado; control en la recepción, suministro y despacho de materiales que se necesitaban; verificación de fallos en el terreno e imprevistos aportando con criterio técnico la solución a todos los inconvenientes presentados donde se dio la oportunidad de investigar y aplicar el conocimiento adquirido en la formación académica brindada por la universidad. Con relación al trabajo de oficina se calculaba las cantidades de obra, actualización de los precios unitarios y elaboración de actas de corte. Para concluir, con las actividades realizadas en esta pasantía se aclararon todas las dudas en algunos conceptos, se aprendieron nuevos conocimientos y algo digno de mencionar es la adquisición del hábito a tomar decisiones, presentar iniciativas en los problemas u/o dificultades presentadas en el desarrollo de este proyecto. Se corroboró todos los valores, principios como la responsabilidad, cumplimiento que un Ingeniero Civil debe tener., Pregrado, Ingeniero(a) Civil, INTRODUCCIÓN ______________________________________________________________ 20 RESUMEN __________________________________________________________________ 16 ABSTRACT __________________________________________________________________ 18 1. Objetivos _______________________________________________________________ 21 1.1 Objetivo general _______________________________________________________ 21 1.2 Objetivos específicos _______________________________________________________ 21 2. Marco teórico ___________________________________________________________ 22 2.1 Datos de la empresa ____________________________________________________ 22 1.1.1 Clases de pavimento ____________________________________________________ 22 1.1.2 Requerimientos Mínimos para la Construcción de Pavimentos Rígidos _____________ 23 2.2 Marco conceptual ______________________________________________________ 24 2.2.1 Antisol: ______________________________________________________________ 24 2.2.2 Acometidas: __________________________________________________________ 24 2.2.3 Alcantarillado: _________________________________________________________ 24 2.2.4 Alcantarilla: ___________________________________________________________ 24 2.2.5 Banca: _______________________________________________________________ 25 2.2.6 Base granular: _________________________________________________________ 25 2.2.7 Berma _______________________________________________________________ 25 2.2.8 Bitácora: _____________________________________________________________ 25 2.2.9 Bombeo: _____________________________________________________________ 25 2.2.10 Calzada: ____________________________________________________________ 26 2.2.11 Canal: _____________________________________________________________ 26 2.2.12 Capacidad: _________________________________________________________ 26 2.2.13 Diseño: ____________________________________________________________ 26 2.2.14 Obra civil: __________________________________________________________ 26 2.2.15 Pavimento: _________________________________________________________ 27 2.2.16 Pavimento articulado: _________________________________________________ 27 2.2.17 Pavimento flexible: ___________________________________________________ 27 2.2.18 Pavimento rígido: ____________________________________________________ 27 2.2.19 Pavimento semi-rígido: ________________________________________________ 28 2.2.20 Presupuesto de obra __________________________________________________ 28 2.2.21 Redes separativas: ___________________________________________________ 28 2.2.22 Redes unitarias: ______________________________________________________ 28 2.2.23 Replanteo: __________________________________________________________ 29 2.2.24 Sub-base granular: ___________________________________________________ 29 2.2.25 Superficie subrasante _________________________________________________ 29 1.2 Marco legal ___________________________________________________________ 30 3. Metodología ____________________________________________________________ 32 3.1 Generalidades ____________________________________________________________ 32 3.2 Objeto __________________________________________________________________ 32 3.2.1 Localización ____________________________________________________________ 32 3.2.2 Actividades de instalación Alcantarillado ____________________________________ 34 3.2.2.1 Actividades de campo _________________________________________________ 34 3.2.3 Actividad de pavimentación ________________________________________________ 46 3.2.4 Actividades de oficina ___________________________________________________ 107 3.2.4.1 Cantidades de obra ____________________________________________________ 107 3.2.4.2 Cuentas de cobro _____________________________________________________ 110 4. Conclusiones ___________________________________________________________ 112 5. ANEXOS _______________________________________________________________ 113 5.1 Anexo No1 – LUIS ALEJANDRO GONZALEZ HERNANDEZ _______________________ 113 5.1.1 INFORMACIÓN _______________________________________________________ 113 5.1.2 ALCANCE ____________________________________________________________ 113 5.1.3 CERTIFICADOS DE CONTRATOS Y EJECUCIÓN. _________________________________ 118 5.2 APU – EMPRESA _________________________________________________________ 123 5.3 Presupuesto de obra – ACTA FINAL___________________________________________ 124 6. Referencias bibliográficas _________________________________________________ 125
- Published
- 2018
14. Los fallos en la virtus nobiliaria de los uxoricidas calderonianos
- Author
-
Tobar Quintanar, Mª José
- Subjects
Noble decorum ,Tragedies of conjugal honour ,Tragedias de honor conyugal ,Failures ,Uxoricidas ,Wife-murderers ,Decoro nobiliario ,Fallos ,Calderón - Abstract
En este trabajo se defiende que el carácter dramático de los tres uxoricidas calderonianos (don Gutierre Alfonso de Solís, don Lope de Almeida y don Juan Roca) no se ajusta en diversas ocasiones al decoro nobiliario que cabría esperar en ellos. Primeramente se establece la nómina de virtudes que se asociaba con la nobleza de manera ideal en la época áurea. Posteriormente, el análisis detallado de la conducta de esos maridos revela fallos en su supuesto diseño como héroes intachables: no dominan sus violentas pasiones, juzgan precipitadamente los datos disponibles y cometen errores en la aplicación del código del honor. Se trata, por tanto, de nobles imperfectos que contribuyen de manera decisiva -aunque inadvertida para ellos- a las tragedias que protagonizan The author of this article defends that the dramatic character of the three Calderonian wife-murderers (don Gutierre Alfonso de Solís, don Lope de Almeida and don Juan Roca) doesn ́t fit to the noble decorum they should have. First the study presents the virtues ideally associated with the nobility in the Golden Age. Afterwards, the detailed analysis of the behaviour of those husbands reveals some failures in their supposed design as perfect heroes: they don ́t dominate their violent passions, they judge precipitately the available data and make some mistakes in the application of the honour code. In consequence, they are imperfect nobles who help in a decisive way —but unnoticed for them—to the tragedies they take the chief role in.
- Published
- 2014
Catalog
Discovery Service for Jio Institute Digital Library