1. Short stem total hip arthroplasty for osteonecrosis of the femoral head in patients 60 years or younger: a 3- to 10-year follow-up study.
- Author
-
Capone, Antonio, Bienati, Fabrizio, Torchia, Stefania, Podda, Daniele, and Marongiu, Giuseppe
- Subjects
TOTAL hip replacement ,OSTEONECROSIS ,FEMUR head ,RADIOGRAPHS ,BONE resorption ,DISEASES ,THERAPEUTICS ,ARTIFICIAL joints ,LONGITUDINAL method ,QUESTIONNAIRES ,TREATMENT effectiveness - Abstract
Background: In young patients with osteonecrosis of the femoral head (ONFH), short-stem total hip arthroplasty (THA) could allow a potential advantage in preserving metaphyseal bone-stock, when revision surgery might become necessary. However, only a few studies have evaluated the outcome of short-stem THAs in ONFH. We reviewed the prospectively collected data of a cementless partial neck-retaining short-stem with ceramic-on-ceramic bearings in ONFH patients.Methods: Thirty patients (37 hips) younger than 60 years (mean age at surgery, 51.5 years) underwent THA with the NANOS® stem (Smith and Nephew, Marl, Germany) from January 2006 to December 2012. All patients received a 32-mm or 36 mm ceramic femoral head. Harris hip score, WOMAC and UCLA activity score were recorded. Postoperative radiographs were evaluated for bone-implant fixation and osteolysis. Further analysis correlated clinical findings with implants characteristics and patient demographics at mean 5.6 years' follow-up (range, 3-10 years).Results: The clinical and functional results improved significantly (p < 0.001). At latest follow-up, mean HHS, WOMAC, and UCLA activity scores were 90 (range, 71-100), 94 (range, 76-100), and 6.3 (range, 4-10) points, respectively. The diameter of the femoral head did not influence the clinical outcome (p = 0.661). All hips showed bone ingrowth fixation of the acetabular and femoral components. No patients showed osteolysis. No revision for any reason was performed during the study period.Conclusions: The excellent clinical results and fixation pattern at mean 5.6 years' follow-up reveal this implant as a reliable option in advanced stage of ONFH either. Further investigations are crucial to determine the long-term durability and to assess whether the association of ceramic-on-ceramic bearings, can be useful to achieve longer survivorship and lower complications rates.Trial Registration: Registry number: ISRCTN 91336248 ; date of registration: 04/07/2017. [ABSTRACT FROM AUTHOR]- Published
- 2017
- Full Text
- View/download PDF