1. Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access® GI Monitor assay on the UniCel® DxI 800 Immunoassay System
- Author
-
Stieber, Petra, Molina, Rafael, Gion, Massimo, Gressner, Axel, Troalen, Frédéric, Holdenrieder, Stefan, Auge, Jose Maria, Zancan, Matelda, Wycislo, Matthias, and Jarrige, Véronique
- Subjects
GASTROINTESTINAL agents ,SYNTHETIC antigens ,BIOMARKERS ,PANCREATITIS ,DILUTION - Abstract
Background: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. Methods: The analytical and clinical performance of the Access
® GI Monitor assay (Beckman Coulter) was evaluated on the UniCel® DxI 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD+7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access® GI Monitor and Elecsys CA19-9 (R=0.959, slope=1.004, intercept=+0.17). GI Monitor serum levels were low in healthy individuals (n=267, median=6.0 kU/L, 95th percentile=23.1 kU/L), higher in individuals with various benign diseases (n=550, medians=5.8–13.4 kU/L, 95th percentiles=30.1–195.5kU/L) and even higher in individuals suffering from various cancers (n=995, medians=8.4–233.8 kU/L, 95th percentiles=53.7–13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer [area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85). Conclusions: The Access® GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers. Clin Chem Lab Med 2008;46:600–11. [ABSTRACT FROM AUTHOR]- Published
- 2008
- Full Text
- View/download PDF