1. Diffusion-weighted imaging: determination of the best pair of b-values to discriminate breast lesions.
- Author
-
Nogueira L, Brandão S, Matos E, Nunes RG, Loureiro J, Ferreira HA, and Ramos I
- Subjects
- Adult, Aged, Aged, 80 and over, Breast pathology, Breast Neoplasms pathology, Carcinoma, Ductal, Breast pathology, Carcinoma, Lobular pathology, Female, Humans, Image Processing, Computer-Assisted, Middle Aged, Prospective Studies, ROC Curve, Reproducibility of Results, Sensitivity and Specificity, Specimen Handling, Young Adult, Breast Neoplasms diagnosis, Carcinoma, Ductal, Breast diagnosis, Carcinoma, Lobular diagnosis, Diffusion Magnetic Resonance Imaging methods, Diffusion Magnetic Resonance Imaging statistics & numerical data
- Abstract
Objective: In breast diffusion-weighted imaging (DWI), the apparent diffusion coefficient (ADC) is used to discriminate between malignant and benign lesions. As ADC estimates can be affected by the weighting factors, our goal was to determine the optimal pair of b-values for discriminating breast lesions at 3.0 T., Methods: 152 females with 157 lesions (89 malignant and 68 benign) underwent breast MRI, including a DWI sequence sampling six b-values 50, 200, 400, 600, 800 and 1000 s mm(-2). ADC values were computed from different pairs of b-values and compared with ADC obtained by fitting the six b-values using a mono-exponential diffusion model (ADCall). Cut-off ADC values were determined and diagnostic performance evaluated by receiver operating characteristic analysis using Youden statistics. Mean ADCs were determined for normal tissue and lesions. Differences were evaluated by lesion and histological types., Results: Considering the cut-off values 1.46 and 1.49 × 10(3)mm(2) s(-1), the pairs 50, 1000 and 200, 800 s mm(-2) showed the highest accuracy, 77.5% and 75.4% with areas under the curve 84.4% and 84.2%, respectively. The best pair for ADC quantification was 50, 1000 s mm(-2) with 38/49 true-negative and 69/89 true-positive cases respectively; mean ADCs were 1.86 ± 0.46, 1.77 ± 0.37 and 1.15 ± 0.46 × 10(-3) mm(2) s(-1) for normal, benign and malignant lesions. There were no significant differences in these ADC values when compared with ADCall (ADC calculated from the full set of b - values) [difference = 0.0075 × 10(-3) mm(2) s(-1); confidence interval 95%: (-0.0036; 0.0186); p = 0.18]., Conclusion: The diagnostic performance in differentiating malignant and benign lesions was most accurate for the b-value pair 50, 1000 s mm(-2)., Advances in Knowledge: The best b-value pair for lesion discrimination and characterization through ADC quantification was 50, 1000 s mm(-2).
- Published
- 2014
- Full Text
- View/download PDF