9 results on '"Scaranna C."'
Search Results
2. Advanced Hybrid Closed-Loop System Achieves and Maintains Recommended Time in Range Levels for Up To 2 Years: Predictors of Best Efficacy.
- Author
-
Lepore G, Borella ND, Castagna G, Ippolito S, Bonfadini S, Corsi A, Scaranna C, Dodesini AR, Bellante R, and Trevisan R
- Subjects
- Adult, Male, Humans, Middle Aged, Blood Glucose Self-Monitoring, Retrospective Studies, Insulin therapeutic use, Insulin, Regular, Human, Hypoglycemic Agents therapeutic use, Insulin Infusion Systems, Blood Glucose, Diabetes Mellitus, Type 1 drug therapy
- Abstract
Aim: To evaluate the long-term efficacy, up to 2 years, of an advanced hybrid closed-loop (AHCL) system and to assess predictors of best results of the therapy. Methods: We retrospectively evaluated 296 adults with type 1 diabetes mellitus [mean age 42.8 ± 16.5 years, men 42.9%, duration of diabetes 22.5 ± 12.8 years, body mass index 24.9 ± 4.7 kg/m
2 , baseline glycated hemoglobin (HbA1c ) 63.4 ± 12.2 mmol/mol (8.0 ± 1.1%) ] who used the MiniMed™ 780G system. Demographic and clinical data were recorded. Continuous glucose monitoring (CGM)-derived metrics and insulin requirement were analyzed from the 4 weeks before and from every quarter after the switch to the AHCL system. Results: In the first quarter of AHCL treatment, all CGM metrics improved. Time in range (TIR) increased from 58.1 ± 17.5% to 70.3 ± 9.5% ( P < 0.0001). The improvement lasted for up to 2 years of observation regardless of previous insulin therapies. Throughout the period of observation, 53.4% of participants achieved mean TIR >70%, 92.6% mean time below range <4%, and 46% mean glucose management indicator <53 mmol/mol (7.0%). At univariable logistic regression older age, lower baseline HbA1c and insulin requirement were associated with mean TIR >70%. At multivariable analysis, lower HbA1c remained independently associated with a better glycemic control. However, mean TIR increased more in participants with a higher baseline HbA1c . Conclusions: Switching to an AHCL leads to a rapid improvement in glycemic control lasting for up to 24 months along with a low risk for hypoglycemia, confirming the safety of the system. Lower baseline HbA1c was the main predictor of better efficacy of therapy, although higher baseline HbA1c was associated with the greatest improvement in mean TIR.- Published
- 2024
- Full Text
- View/download PDF
3. Real-World Insulin Treatment in Pregnant Women with Type 1 Diabetes Using an Advanced Hybrid Closed-Loop System.
- Author
-
Dodesini AR, Borella ND, Lepore G, Bonfadini S, Corsi A, Scaranna C, Bellante R, and Trevisan R
- Subjects
- Female, Pregnancy, Humans, Pregnant People, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Blood Glucose, Insulin Infusion Systems, Blood Glucose Self-Monitoring, Diabetes Mellitus, Type 1 drug therapy
- Published
- 2023
- Full Text
- View/download PDF
4. Switching to the Minimed™ 780G system achieves clinical targets for CGM in adults with type 1 diabetes regardless of previous insulin strategy and baseline glucose control.
- Author
-
Lepore G, Rossini A, Bellante R, Corsi A, Scaranna C, Dodesini AR, and Trevisan R
- Subjects
- Adult, Blood Glucose, Blood Glucose Self-Monitoring, Female, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Insulin Infusion Systems, Male, Middle Aged, Retrospective Studies, Diabetes Mellitus, Type 1 drug therapy
- Abstract
Aims: Advanced hybrid closed-loop (AHCL) systems represent the latest introduction in the treatment of type 1 diabetes (T1DM). Randomized controlled trials and real-world evidence studies showed that AHCL systems are a safe and effective insulin management strategy. Aim of this retrospective, single-center, real-life study was to evaluate the effect on metabolic control, evaluated by continuous glucose monitoring (CGM) metrics, of the switch from four available insulin strategies to an AHCL system in adult patients with type 1 diabetes., Methods: A total of 102 patients with T1DM (mean age 42.1 ± 16.3 years, males/females 47/55, duration of diabetes 21.4 ± 13.3 years, BMI 24.4 ± 4.5 kg/m
2 , HbA1c 59.9 ± 9.6 mmol/mol or 7.6 ± 0.9%), treated with four different insulin therapies [multiple daily insulin (MDI) therapy, continuous subcutaneous insulin infusion (CSII), sensor-augmented pump (SAP) with predictive low-glucose suspend (PLGS), and hybrid closed loop (HCL) system] were evaluated before hand, two months and six months after switching to an AHCL (Minimed™ 780G system, Medtronic, Northridge, CA) system., Results: Two months after the switch, mean GCM metrics improved in all four treatment groups. Six months after the switch, the participants of all four groups achieved a mean GMI < 53 mmol/mol, TIR > 70%, TBR < 4%, and CV < 36%, which is recommended by the ADA Standard of Medical Care in Diabetes 2022, including the MDI group with worse baseline glycemic control., Conclusions: Switching to an AHCL leads to a rapid improvement in glycemic control lasting for up to six months independently of previous insulin treatment and baseline conditions., (© 2022. Springer-Verlag Italia S.r.l., part of Springer Nature.)- Published
- 2022
- Full Text
- View/download PDF
5. Continuous subcutaneous insulin infusion reduces maternal and neonatal risk in pregnant women with type 1 diabetes: An observational cohort study of 122 pregnancies.
- Author
-
Dodesini AR, Cavalli G, Ciriello E, Lepore G, Corsi A, Scaranna C, Bellante R, Albizzi M, Galliani S, Mangili G, and Trevisan R
- Subjects
- Adult, Aged, Cohort Studies, Female, Humans, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use, Infant, Newborn, Infusions, Subcutaneous, Injections, Insulin administration & dosage, Insulin Infusion Systems, Pregnancy, Treatment Outcome, Diabetes Mellitus, Type 1 drug therapy, Insulin therapeutic use
- Published
- 2020
- Full Text
- View/download PDF
6. Switching from Suspend-Before-Low Insulin Pump Technology to a Hybrid Closed-Loop System Improves Glucose Control and Reduces Glucose Variability: A Retrospective Observational Case-Control Study.
- Author
-
Lepore G, Scaranna C, Corsi A, Dodesini AR, and Trevisan R
- Subjects
- Adult, Blood Glucose analysis, Blood Glucose Self-Monitoring, Case-Control Studies, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 complications, Female, Humans, Hypoglycemia etiology, Hypoglycemia prevention & control, Male, Middle Aged, Retrospective Studies, Treatment Outcome, Diabetes Mellitus, Type 1 drug therapy, Glycemic Control instrumentation, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
There are no data whether hybrid closed-loop (HCL) systems are superior to sensor-augmented pump (SAP) therapy with predictive low glucose suspend (PLGS) feature in improving glucose control. Aim of our study was to evaluate the effect on metabolic control and glucose variability of the switch from SAP therapy with PLGS to a HCL system in type 1 diabetic individuals. Forty adults with type 1 diabetes, who had been using SAP therapy with PLGS feature (Minimed 640G; Medtronic, Northridge, CA) for at least 12 months were evaluated in a 6-month case-control observational retrospective study. Twenty subjects who consecutively switched from Minimed 640G to a HCL system (Minimed 670G; Medtronic) (670G group) were compared with a control group consisting of 20 subjects who continued with the MiniMed 640G pump (640G group) matched for age, gender, and HbA
1c . At the end of the study there was a significant reduction in average HbA1c levels (-4.9 ± 6.4 mmol/mol [-0.4% ± 0.6%], P < 0.01), sensor glucose concentrations (-15.4 ± 17.7 mg/dL, P < 0.005), coefficient of variation of sensor glucose concentrations (-3.8% ± 3.6%, P < 0.01), percentage time spent in both hyperglycemic range 181-250 mg/dL (-5.1% ± 4.5%, P < 0.05), and >250 mg/dL (-6.1% ± 6.9%, P < 0.05) in the 670G group, whereas they remained unchanged in the 640G group. Percentage of time spent in euglycemic range significantly increased (11.6% ± 8.3%, P < 0.005) only in the 670G group. There was no change in time spent in hypoglycemic range in both groups. In adults with type 1 diabetes, switching from a 640G to a 670G system significantly improved glucose control and reduced glucose variability, thus reaching in most cases the recommended targets for time spent in euglycemic and hyperglycemic ranges without increasing the risk of hypoglycemia.- Published
- 2020
- Full Text
- View/download PDF
7. Bolus calculator improves long-term metabolic control and reduces glucose variability in pump-treated patients with Type 1 diabetes.
- Author
-
Lepore G, Dodesini AR, Nosari I, Scaranna C, Corsi A, and Trevisan R
- Subjects
- Adult, Automation, Biomarkers blood, Blood Glucose metabolism, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 diagnosis, Equipment Design, Female, Glycated Hemoglobin metabolism, Humans, Hypoglycemia chemically induced, Hypoglycemia prevention & control, Hypoglycemic Agents adverse effects, Infusions, Subcutaneous, Insulin adverse effects, Male, Middle Aged, Software Design, Time Factors, Treatment Outcome, Blood Glucose drug effects, Blood Glucose Self-Monitoring instrumentation, Diabetes Mellitus, Type 1 drug therapy, Drug Dosage Calculations, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Published
- 2012
- Full Text
- View/download PDF
8. Metabolic control and complications in Italian people with diabetes treated with continuous subcutaneous insulin infusion
- Author
-
Giuseppe Lepore, Riccardo Bonfanti, Lutgarda Bozzetto, Vincenzo Di Blasi, Angela Girelli, Giorgio Grassi, Dario Iafusco, Luigi Laviola, Ivana Rabbone, Riccardo Schiaffini, Daniela Bruttomesso, F. Mammì, M. Bruzzese, M. Schettino, M.G. Nuzzo, V. Di Blasi, R. Fresa, C. Lambiase, D. Iafusco, A. Zanfardino, S. Confetto, L. Bozzetto, G. Annuzzi, A. Alderisio, G. Riccardi, S. Gentile, G. Marino, G. Guarino, S. Zucchini, G. Maltoni, T. Suprani, V. Graziani, M. Nizzoli, S. Acquati, R. Cavani, S. Romano, M. Michelini, E. Manicardi, R. Bonadonna, A. Dei Cas, E. Dall'aglio, M. Papi, S. Riboni, V. Manicardi, V. Pugni, A. Lasagni, M.E. Street, U. Pagliani, C. Rossi, R. Assaloni, B. Brunato, C. Tortul, G. Zanette, P. Li Volsi, M. Zanatta, L. Tonutti, S. Agus, M.A. Pellegrini, P. Ceccano, G. Pozzilli, Beretta Anguissola, R. Buzzetti, C. Moretti C, G. Leto, P. Pozzilli, S. Manfrini, A.R. Maurizi, S. Leotta, M. Altomare, S. Abbruzzese, S. Carletti, C. Suraci, S. Filetti, M.L. Manca Bitti, S. Arcano, M.G. Cavallo, M. De Bernardinis, D. Pitocco, S. Caputo, A. Rizzi, A. Manto, R. Schiaffini, M. Cappa, D. Benevento, S. Frontoni, I. Malandrucco, S. Morano, T. Filardi, D. Lauro, M.A. Marini, E. Castaldo, D. Sabato, F. Tuccinardi, E. Forte, P. Viterbori, C. Arnaldi, N. Minuto, G. d'Annunzio, A. Corsi, R. Rota, C. Scaranna, R. Trevisan, U. Valentini, A. Girelli, S. Bonfadini, E. Zarra, A. Plebani, E. Prandi, B. Felappi, A. Rocca, E. Meneghini, P. Galli, P. Ruggeri, E. Carrai, L. Fugazza, V. Baggi, D. Conti, E. Bosi, A. Laurenzi, A. Caretto, C. Molinari, E. Orsi, V. Grancini, V. Resi, R. Bonfanti, V. Favalli, C. Bonura, A. Rigamonti, M. Bonomo, F. Bertuzzi, B. Pintaudi, O. Disoteo, G. Perseghin, S. Perra, L. Chiovato, P. De Cata, F. Zerbini, E. Lovati, M. Laneri, L. Guerraggio, A.C. Bossi, V. De Mori, M. Galetta, I. Meloncelli, A. Aiello A, S. Di Vincenzo, A. Nuzzi, E. Fraticelli, E. Ansaldi, M. Battezzati, M. Lombardi, M. Balbo, R. Lera, A. Secco, V. De Donno, F. Cadario, S. Savastio, C. Ponzani, G. Aimaretti, I. Rabbone, G. Ignaccolo, D. Tinti, F. Cerutti, F. Bari, F. Giorgino, E. Piccinno, O. Zecchino, M. Cignarelli, O. Lamacchia, G. Picca, S. De Cosmo, A. Rauseo, L. Tomaselli, A. Tumminia, C. Egiziano, A.M. Scarpitta, F. Maggio, F. Cardella, R. Roppolo, V. Provenzano, M. Fleres, A. Scorsone, A. Scatena, G. Gregori, S. Lucchesi, F. Gadducci, S. Di Cianni, S. Pancani, S. Del Prato, M. Aragona, I. Crisci, A. Calianno, B. Fattor, D. Crazzolara, P. Reinstadler, S. Longhi, G. Incelli, S. Rauch, T. Romanelli, M. Orrasch, V. Cauvin, R. Franceschi, C. Lalli, A. Pianta, A. Marangoni, C.N. Aricò, N. Marin, N. Nogara, N. Simioni, A. Filippi, G.L. Gidoni Guarneri, M.L. Contin M.L, A.P. Decata, L. Bondesan, L. Confortin, A. Coracina, S. Lombardi, S. Costa Padova, E. Cipponeri, R. Scotton, S. Galasso, F. Boscari, M.S. Zanon, C. Vinci, G. Lisato, L. Gottardo, E. Bonora, M. Trombetta, C. Negri, C. Brangani, C. Maffeis, A. Sabbion, M. Marigliano, Lepore, Giuseppe, Bonfanti, Riccardo, Bozzetto, Lutgarda, Di Blasi, Vincenzo, Girelli, Angela, Grassi, Giorgio, Iafusco, Dario, Laviola, Luigi, Rabbone, Ivana, Schiaffini, Riccardo, Bruttomesso, Daniela, Lepore, G., Bonfanti, R., Bozzetto, L., Di Blasi, V., Girelli, A., Grassi, G., Iafusco, D., Laviola, L., Rabbone, I., Schiaffini, R., Bruttomesso, D., Mammi, F., Bruzzese, M., Schettino, M., Nuzzo, M. G., Fresa, R., Lambiase, C., Zanfardino, A., Confetto, S., Annuzzi, G., Alderisio, A., Riccardi, G., Gentile, S., Marino, G., Guarino, G., Zucchini, S., Maltoni, G., Suprani, T., Graziani, V., Nizzoli, M., Acquati, S., Cavani, R., Romano, S., Michelini, M., Manicardi, E., Bonadonna, R., Dei Cas, A., Dall'Aglio, E., Papi, M., Riboni, S., Manicardi, V., Pugni, V., Lasagni, A., Street, M. E., Pagliani, U., Rossi, C., Assaloni, R., Brunato, B., Tortul, C., Zanette, G., Li Volsi, P., Zanatta, M., Tonutti, L., Agus, S., Pellegrini, M. A., Ceccano, P., Pozzilli, G., Anguissola, B., Buzzetti, R., Moretti C, C., Leto, G., Pozzilli, P., Manfrini, S., Maurizi, A. R., Leotta, S., Altomare, M., Abbruzzese, S., Carletti, S., Suraci, C., Filetti, S., Manca Bitti, M. L., Arcano, S., Cavallo, M. G., De Bernardinis, M., Pitocco, D., Caputo, S., Rizzi, A., Manto, A., Cappa, M., Benevento, D., Frontoni, S., Malandrucco, I., Morano, S., Filardi, T., Lauro, D., Marini, M. A., Castaldo, E., Sabato, D., Tuccinardi, F., Forte, E., Viterbori, P., Arnaldi, C., Minuto, N., D'Annunzio, G., Corsi, A., Rota, R., Scaranna, C., Trevisan, R., Valentini, U., Bonfadini, S., Zarra, E., Plebani, A., Prandi, E., Felappi, B., Rocca, A., Meneghini, E., Galli, P., Ruggeri, P., Carrai, E., Fugazza, L., Baggi, V., Conti, D., Bosi, E., Laurenzi, A., Caretto, A., Molinari, C., Orsi, E., Grancini, V., Resi, V., Favalli, V., Bonura, C., Rigamonti, A., Bonomo, M., Bertuzzi, F., Pintaudi, B., Disoteo, O., Perseghin, G., Perra, S., Chiovato, L., De Cata, P., Zerbini, F., Lovati, E., Laneri, M., Guerraggio, L., Bossi, A. C., De Mori, V., Galetta, M., Meloncelli, I., Aiello A, A., Di Vincenzo, S., Nuzzi, A., Fraticelli, E., Ansaldi, E., Battezzati, M., Lombardi, M., Balbo, M., Lera, R., Secco, A., De Donno, V., Cadario, F., Savastio, S., Ponzani, C., Aimaretti, G., Ignaccolo, G., Tinti, D., Cerutti, F., Bari, F., Giorgino, F., Piccinno, E., Zecchino, O., Cignarelli, M., Lamacchia, O., Picca, G., De Cosmo, S., Rauseo, A., Tomaselli, L., Tumminia, A., Egiziano, C., Scarpitta, A. M., Maggio, F., Cardella, F., Roppolo, R., Provenzano, V., Fleres, M., Scorsone, A., Scatena, A., Gregori, G., Lucchesi, S., Gadducci, F., Di Cianni, S., Pancani, S., Del Prato, S., Aragona, M., Crisci, I., Calianno, A., Fattor, B., Crazzolara, D., Reinstadler, P., Longhi, S., Incelli, G., Rauch, S., Romanelli, T., Orrasch, M., Cauvin, V., Franceschi, R., Lalli, C., Pianta, A., Marangoni, A., Arico, C. N., Marin, N., Nogara, N., Simioni, N., Filippi, A., Gidoni Guarneri, G. L., Contin, M. L M. L., Decata, A. P., Bondesan, L., Confortin, L., Coracina, A., Lombardi, S., Costa Padova, S., Cipponeri, E., Scotton, R., Galasso, S., Boscari, F., Zanon, M. S., Vinci, C., Lisato, G., Gottardo, L., Bonora, E., Trombetta, M., Negri, C., Brangani, C., Maffeis, C., Sabbion, A., Marigliano, M., Lepore, G, Bonfanti, R, Bozzetto, L, Di Blasi, V, Girelli, A, Grassi, G, Iafusco, D, Laviola, L, Rabbone, I, Schiaffini, R, Bruttomesso, D, Mammi, F, Bruzzese, M, Schettino, M, Nuzzo, M, Fresa, R, Lambiase, C, Zanfardino, A, Confetto, S, Annuzzi, G, Alderisio, A, Riccardi, G, Gentile, S, Marino, G, Guarino, G, Zucchini, S, Maltoni, G, Suprani, T, Graziani, V, Nizzoli, M, Acquati, S, Cavani, R, Romano, S, Michelini, M, Manicardi, E, Bonadonna, R, Dei Cas, A, Dall'Aglio, E, Papi, M, Riboni, S, Manicardi, V, Pugni, V, Lasagni, A, Street, M, Pagliani, U, Rossi, C, Assaloni, R, Brunato, B, Tortul, C, Zanette, G, Li Volsi, P, Zanatta, M, Tonutti, L, Agus, S, Pellegrini, M, Ceccano, P, Pozzilli, G, Anguissola, B, Buzzetti, R, Moretti C, C, Leto, G, Pozzilli, P, Manfrini, S, Maurizi, A, Leotta, S, Altomare, M, Abbruzzese, S, Carletti, S, Suraci, C, Filetti, S, Manca Bitti, M, Arcano, S, Cavallo, M, De Bernardinis, M, Pitocco, D, Caputo, S, Rizzi, A, Manto, A, Cappa, M, Benevento, D, Frontoni, S, Malandrucco, I, Morano, S, Filardi, T, Lauro, D, Marini, M, Castaldo, E, Sabato, D, Tuccinardi, F, Forte, E, Viterbori, P, Arnaldi, C, Minuto, N, D'Annunzio, G, Corsi, A, Rota, R, Scaranna, C, Trevisan, R, Valentini, U, Bonfadini, S, Zarra, E, Plebani, A, Prandi, E, Felappi, B, Rocca, A, Meneghini, E, Galli, P, Ruggeri, P, Carrai, E, Fugazza, L, Baggi, V, Conti, D, Bosi, E, Laurenzi, A, Caretto, A, Molinari, C, Orsi, E, Grancini, V, Resi, V, Favalli, V, Bonura, C, Rigamonti, A, Bonomo, M, Bertuzzi, F, Pintaudi, B, Disoteo, O, Perseghin, G, Perra, S, Chiovato, L, De Cata, P, Zerbini, F, Lovati, E, Laneri, M, Guerraggio, L, Bossi, A, De Mori, V, Galetta, M, Meloncelli, I, Aiello A, A, Di Vincenzo, S, Nuzzi, A, Fraticelli, E, Ansaldi, E, Battezzati, M, Lombardi, M, Balbo, M, Lera, R, Secco, A, De Donno, V, Cadario, F, Savastio, S, Ponzani, C, Aimaretti, G, Ignaccolo, G, Tinti, D, Cerutti, F, Bari, F, Giorgino, F, Piccinno, E, Zecchino, O, Cignarelli, M, Lamacchia, O, Picca, G, De Cosmo, S, Rauseo, A, Tomaselli, L, Tumminia, A, Egiziano, C, Scarpitta, A, Maggio, F, Cardella, F, Roppolo, R, Provenzano, V, Fleres, M, Scorsone, A, Scatena, A, Gregori, G, Lucchesi, S, Gadducci, F, Di Cianni, S, Pancani, S, Del Prato, S, Aragona, M, Crisci, I, Calianno, A, Fattor, B, Crazzolara, D, Reinstadler, P, Longhi, S, Incelli, G, Rauch, S, Romanelli, T, Orrasch, M, Cauvin, V, Franceschi, R, Lalli, C, Pianta, A, Marangoni, A, Arico, C, Marin, N, Nogara, N, Simioni, N, Filippi, A, Gidoni Guarneri, G, Contin, M, Decata, A, Bondesan, L, Confortin, L, Coracina, A, Lombardi, S, Costa Padova, S, Cipponeri, E, Scotton, R, Galasso, S, Boscari, F, Zanon, M, Vinci, C, Lisato, G, Gottardo, L, Bonora, E, Trombetta, M, Negri, C, Brangani, C, Maffeis, C, Sabbion, A, and Marigliano, M
- Subjects
Blood Glucose ,Male ,Pediatrics ,Acute and chronic complication ,Glycated Hemoglobin A ,Time Factors ,Endocrinology, Diabetes and Metabolism ,medicine.medical_treatment ,Medicine (miscellaneous) ,Ketosi ,Infusions, Subcutaneous ,Settore MED/13 - Endocrinologia ,Acute and chronic complications ,Continuous subcutaneous insulin infusion (CSII) ,Diabetes mellitus ,Metabolic control ,Nutrition and Dietetics ,Cardiology and Cardiovascular Medicine ,0302 clinical medicine ,Endocrinology ,Adolescent ,Adult ,Albuminuria ,Biomarkers ,Child ,Cross-Sectional Studies ,Diabetes Mellitus, Type 1 ,Diabetes Mellitus, Type 2 ,Diabetic Nephropathies ,Diabetic Retinopathy ,Female ,Health Care Surveys ,Humans ,Hypertension ,Hypoglycemia ,Hypoglycemic Agents ,Insulin ,Italy ,Ketosis ,Middle Aged ,Risk Factors ,Treatment Outcome ,Young Adult ,Insulin Infusion Systems ,030212 general & internal medicine ,Subcutaneous ,Diabetic retinopathy ,Diabetes and Metabolism ,medicine.symptom ,Type 2 ,Human ,Type 1 ,Insulin pump ,Infusions ,medicine.medical_specialty ,Diabetes mellitu ,Time Factor ,030209 endocrinology & metabolism ,03 medical and health sciences ,medicine ,Cross-Sectional Studie ,Glycated Hemoglobin ,Type 1 diabetes ,Hypoglycemic Agent ,business.industry ,Risk Factor ,Biomarker ,medicine.disease ,Ketoacidosis ,Infusions, Subcutaneou ,Health Care Survey ,Diabetic Nephropathie ,business - Abstract
Background and aim: The objective of this cross-sectional study was to evaluate the degree of glycaemic control and the frequency of diabetic complications in Italian people with diabetes who were treated with continuous subcutaneous insulin infusion (CSII). Methods and results: Questionnaires investigating the organisation of diabetes care centres, individuals’ clinical and metabolic features and pump technology and its management were sent to adult and paediatric diabetes centres that use CSII for treatment in Italy. Information on standard clinical variables, demographic data and acute and chronic diabetic complications was derived from local clinical management systems. The sample consisted of 6623 people with diabetes, which was obtained from 93 centres. Of them, 98.8% had type 1 diabetes mellitus, 57.2% were female, 64% used a conventional insulin pump and 36% used a sensor-augmented insulin pump. The median glycated haemoglobin (HbA1c) level was 60 mmol/mol (7.6%). The HbA1c target (i.e. 18 years) was achieved in 43.4% of paediatric and 23% of adult participants. Factors such as advanced pump functions, higher rate of sensor use, pregnancy in the year before the study and longer duration of diabetes were associated with lower HbA1c levels. The most common chronic complications occurring in diabetes were retinopathy, microalbuminuria and hypertension. In the year before the study, 5% of participants reported ≥1 episode of severe hypoglycaemic (SH) episodes (SH) and 2.6% reported ≥1 episode of ketoacidosis. Conclusions: Advanced personal skills and use of sensor-based pump are associated with better metabolic control outcomes in Italian people with diabetes who were treated with CSII. The reduction in SH episodes confirms the positive effect of CSII on hypoglycaemia. Clinical trial registration number: NCT 02620917 (ClinicalTrials.gov).
- Published
- 2018
9. Bolus calculator improves long-term metabolic control and reduces glucose variability in pump-treated patients with Type 1 diabetes
- Author
-
C. Scaranna, I. Nosari, Giuseppe Lepore, R. Trevisan, Anna Maria Corsi, Alessandro Roberto Dodesini, Lepore, G, Dodesini, A, Nosari, I, Scaranna, C, Corsi, A, and Trevisan, R
- Subjects
Adult ,Blood Glucose ,Male ,medicine.medical_specialty ,Time Factors ,Endocrinology, Diabetes and Metabolism ,Medicine (miscellaneous) ,Infusions, Subcutaneous ,Automation ,Bolus (medicine) ,Insulin Infusion Systems ,Software Design ,Internal medicine ,medicine ,Humans ,Hypoglycemic Agents ,Insulin ,Drug Dosage Calculations ,Glycated Hemoglobin ,Type 1 diabetes ,Nutrition and Dietetics ,business.industry ,Blood Glucose Self-Monitoring ,Equipment Design ,type 1 diabetes, glucose variability, bolus calculator ,Middle Aged ,medicine.disease ,Hypoglycemia ,Diabetes Mellitus, Type 1 ,Treatment Outcome ,Metabolic control analysis ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Biomarkers - Published
- 2012
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.