1. Effects of an MDP-based surface cleaner on dentin structure, morphology and nanomechanical properties.
- Author
-
Toledano M, Osorio E, Espigares J, González-Fernández JF, and Osorio R
- Subjects
- Humans, Dentin chemistry, Resin Cements chemistry, Phosphoric Acids pharmacology, Phosphoric Acids chemistry, Saliva, Surface Properties, Microscopy, Electron, Scanning, Materials Testing, Dentin-Bonding Agents chemistry, Dental Bonding methods
- Abstract
Objective: To analyze the effect of Katana™ Cleaner (KC) in nanomechanical and triboscopic properties of etched dentin., Methods: Dentin disks from human third molars were prepared. Two main groups of study were established in function of the etching conditioning, phosphoric acid (PA) and Clearfil SE Bond primer (CSEB). Four subgroups were tested within each group: i) untreated dentin (UD), ii) etched dentin (ED) [(PAED/CSEB)], iii) etched dentin contaminated with saliva (PAED+S)/(CSEB+S), and iv) etched and contaminated dentin treated with KC (PAED+S+KC)/(CSEB+S+KC). Nano-DMA testing and imaging, atomic force microscopy (AFM) analysis and nanoroughness (SRa) measurements were obtained. Field emission scanning electron microscopy (FESEM) images were also acquired., Results: Phosphoric acid etched dentin samples and those specimens contaminated with saliva (PAED+S) attained the highest SRa values, that decreased after Katana™ Cleaner application (PAED+S+KC). In the group of dentin treated with CSEB primer, all subgroups performed similar, except in CSEB+S that attained the highest SRa values. The treatment with KC restored the original values of complex modulus of the untreated dentin. KC application produced the lowest and the highest tan delta values on PAED and CSEB groups, respectively., Conclusion: Katana™ Cleaner provided equally mature dentin surfaces after any of the etching methods. Tan delta increased when Katana™ Cleaner was applied on the dentin surface previously etched and contaminated with saliva, regardless the kind of etchant, thus facilitating the dissipation of energy for elastic recoil during loading., Clinical Significance: Katana™ Cleaner application after saliva contamination originated similar low roughness levels, regardless the type of etching method. Both complex and storage moduli were similar, after Katana™ Cleaner application, in any case., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 Elsevier Ltd. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF