1. Accuracy of a Novel SARS-CoV-2 Antigen-Detecting Rapid Diagnostic Test from Standardized Self-Collected Anterior Nasal Swabs.
- Author
-
Osmanodja, Bilgin, Budde, Klemens, Zickler, Daniel, Naik, Marcel G., Hofmann, Jörg, Gertler, Maximilian, Hülso, Claudia, Rössig, Heike, Horn, Philipp, Seybold, Joachim, Lunow, Stephanie, Bothmann, Melanie, Barrera-Pesek, Astrid, Mayrdorfer, Manuel, and Petrosillo, Nicola
- Subjects
SARS-CoV-2 ,COVID-19 pandemic ,NASOPHARYNX ,DIAGNOSIS methods ,STANDARDIZED tests ,NASAL mucosa ,POLYMERASE chain reaction ,DIAGNOSTIC services - Abstract
Background Antigen-detecting rapid diagnostic tests (Ag-RDT) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) offer new opportunities for the quick and laboratory-independent identification of infected individuals for control of the SARS-CoV-2 pandemic. Despite the potential benefits, nasopharyngeal sample collection is frequently perceived as uncomfortable by patients and requires trained healthcare personnel with protective equipment. Therefore, anterior nasal self-sampling is increasingly recognized as a valuable alternative. Methods We performed a prospective, single-center, point of care validation of an Ag-RDT using a polypropylene absorbent collector for standardized self-collected anterior nasal swabs. Real-time polymerase chain reaction (RT-PCR) from combined oropharyngeal/nasopharyngeal swabs served as a comparator. Primary endpoint was sensitivity of the standardized Ag-RDT in symptomatic patients with medium or high viral concentration (≥1 million RNA copies on RT-PCR for SARS-CoV-2). Results Between 12 February and 22 March 2021, 388 participants were enrolled. After exclusion of 9 patients for which no PCR result could be obtained, the novel Ag-RDT was evaluated based on 379 participants, of whom 273 were symptomatic and 106 asymptomatic. In 61 samples from symptomatic patients with medium or high viral load (≥1 million RNA copies), the sensitivity of the standardized Ag-RDT was 96.7% (59/61; 95% confidence interval (CI): 88.7–99.6%) for the primary endpoint. In total, 62 positive Ag-RDT results were detected out of 70 RT-PCR positive individuals, yielding an overall sensitivity of 88.6% (95% CI: 78.7–94.9%). Specificity was 99.7% (95% CI: 98.2–100%) in 309 RT-PCR negative individuals. Conclusions Here, we present a validation of a novel Ag-RDT with a standardized sampling process for anterior nasal self-collection, which meets World Health Organisation (WHO) criteria of ≥80% sensitivity and ≥97% specificity. Although less sensitive than RT-PCR, this assay could be beneficial due to its rapid results, ease of use, and suitability for standardized self-testing. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF