1. Reliability of dutch obstetric telephone triage
- Author
-
Bernice Engeltjes, Doug Cronie, Ageeth Rosman, Fedde Scheele, Eveline Wouters, Loes C.M. Bertens, Athena Institute, Obstetrics & Gynecology, Tranzo, Scientific center for care and wellbeing, and Technological and Social Innovation for Mental Health
- Subjects
Inter observer agreement ,artikel tijdschrift ,Obstetric care ,SDG 3 - Good Health and Well-being ,medicine ,intra-observer agreement ,Telephone triage ,Reliability (statistics) ,Original Research ,Risk Management and Healthcare Policy ,inter-observer agreement ,obstetrics ,business.industry ,Health Policy ,undertriage and overtriage ,Public Health, Environmental and Occupational Health ,medicine.disease ,Triage ,triage system ,Vignette ,Medical emergency ,Public aspects of medicine ,RA1-1270 ,business ,Kappa - Abstract
Bernice Engeltjes,1,2 Ageeth Rosman,2 Loes CM Bertens,3 Eveline Wouters,4 Doug Cronie,2 Fedde Scheele1,5 1Athena Institute for Transdisciplinary Research, Faculty of Science, VU University, Amsterdam, the Netherlands; 2Department of Healthcare Studies, Rotterdam University of Applied Sciences, Rotterdam, the Netherlands; 3Department of Obstetrics and Gynecology, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, the Netherlands; 4Department of Tranzo, Tilburg School of Social and Behavioral Sciences, Tilburg University, Tilburg, the Netherlands; 5Department of Healthcare Education, OLVG Teaching Hospital, Amsterdam, the NetherlandsCorrespondence: Bernice EngeltjesDepartment of Healthcare Studies, Rotterdam University of Applied Sciences, Rotterdam, the NetherlandsTel +31 6 41804881Email engeltjesbernice@gmail.comBackground: Safety and efficiency of emergency care can be optimized with a triage system which uses urgency to prioritize care. The Dutch Obstetric Telephone Triage System (DOTTS) was developed to provide a basis for assessing urgency of unplanned obstetric care requests by telephone. Reliability and validity are important components in evaluating such (obstetric) triage systems.Objective: To determine the reliability of Dutch Obstetric Telephone Triage, by calculating the inter-rater and intra-rater reliability.Methods: To evaluate the urgency levels of DOTTS by testing inter-rater and intra-rater reliability, 90 vignettes of possible requests were developed. Nineteen participants, from hospitals where DOTTS had been implemented, rated in two rounds a set of ten vignettes. The five urgency levels and five presenting symptoms had an equal spread and had to be entered in accordance with DOTTS per vignette. Urgency levels were dichotomized into high urgency and intermediate urgency. Inter-rater reliability was rated as degree of agreement between two different participants with the same vignette. Intra-rater reliability was rated as agreement by the same participants at different moments in time. The degree of inter-rater and intra-rater reliability was tested using weighted Cohenâs Kappa and ICC.Results: The agreement of urgency level between participants in accordance with predefined urgency level per vignette was 90.5% (95% CI 87.5â 93.6) [335 of 370]. Agreement of urgency level between participants was 88.5% (95% CI 84.9â 93.0) [177 of 200] and 84.9% (95% CI 78.3â 91.4) after re-rating [101 of 119]. Inter-rater reliability of DOTTS expressed as Cohenâs Kappa was 0.77 and as ICC 0.87; intra-rater reliability of DOTTS expressed as Cohenâs Kappa was 0.70 and as ICC 0.82.Conclusion: Inter-rater and intra-rater reliability of DOTTS showed substantial correlation, and is comparable to other studies. Therefore, DOTTS is considered reliable.Keywords: obstetrics, triage system, inter-observer agreement, intra-observer agreement, undertriage and overtriage
- Published
- 2021
- Full Text
- View/download PDF