Antonio Di Lonardo, Anna Maria Tamisani, Paolo Cerulli, Maria Giuseppina Onesti, Giorgio Stracuzzi, Davide Melandri, Gianpiero Gravante, G. Esposito, Antonio Merone, Roberto Sorge, Giovanna Doneddu, Raimondo Pinn, and Alessandro Scalise
Results of a national retrospective survey on Hyalomatrix PA in burn patients are reported.A total of 11 burn centers were contacted.A total of 57 patients were available. Hyalomatrix PA was used on young and adult patients, mainly in deep partial thickness and full thickness burns. In most cases, Hyalomatrix PA was applied immediately after the wound cleaning (wound debridement or escharectomy for adults, dermabrasion or debridement in young patients). After 7 days, reepithelization processes were more frequent in deep partial thickness burns. One-half of the patient population underwent grafting. After 29 days, complete closure was achieved in almost all patients. The Vancouver Scar Scale showed better values for adults, while no differences were observed for burn depth or patients undergoing grafting. No adverse reactions were recorded.Hyalomatrix PA is used in young and adults, in deep partial thickness and full thickness burns, as a temporary coverage before grafting or alone for wound healing.