1. Adopting permanent His bundle pacing: learning curves and medium-term outcomes
- Author
-
Eugene Tan, Rodney Soh, Pipin Kojodjojo, Elaine Boey, Jie Ying Lee, Vern Hsen Tan, Jhobeleen De Leon, Swee-Chong Seow, Colin Yeo, Lisa Jie Ting Teo, and Hiong Hiong Gan
- Subjects
Male ,Bundle of His ,medicine.medical_specialty ,medicine.medical_treatment ,Cardiac resynchronization therapy ,Ventricular Function, Left ,Medium term ,Cardiac Resynchronization Therapy ,Electrocardiography ,QRS complex ,Physiology (medical) ,Internal medicine ,Humans ,Medicine ,Aged ,Aged, 80 and over ,Ejection fraction ,Intention-to-treat analysis ,business.industry ,Cardiac Pacing, Artificial ,Stroke Volume ,Odds ratio ,Middle Aged ,medicine.disease ,Treatment Outcome ,Cardiology ,Female ,Implant ,Cardiology and Cardiovascular Medicine ,business ,Atrioventricular block ,Learning Curve - Abstract
Aims This study aims to determine procedural characteristics, acute success rates, and medium-term outcomes of consecutive patients undergoing His bundle pacing (HBP); and learning curves of experienced electrophysiologists adopting HBP. Methods and results Consecutive HBP patients at three hospitals were recruited. Clinical characteristics, acute procedural details, and medium-term outcomes were extracted from electronic medical records. Two hundred and thirty-three patients [mean age 74.6 ± 10.1 years, 48% female, 68% narrow QRS, 71% normal left ventricular ejection fraction (LVEF), 55.8% atrioventricular block] underwent HBP. Acute procedural success was 81.1% (mean procedural and fluoroscopic times of 105.5 ± 36.5 and 13.8 ± 9.3 min). Broad QRS was associated with lower HBP success (odds ratio 0.39, P = 0.02). Fluoroscopic and procedural times decreased and plateaued after 30–40 cases per operator. Implant HBP threshold was 1.3 ± 0.7 V at 1.0 ± 0.2 ms and R wave was 5.0 ± 3.9 mV. During follow-up, loss of HBP occurred in a further 12.4% and 11.3% of patients experienced a ≥1 V increase in HBP threshold. Five (2.6%) patients required HBP revision for pacing difficulties. About 8.6% of patients had a >50% decrease in R wave but lead revision for sensing issues was not necessary. On an intention to treat basis, 56.7% of patients in whom HBP was attempted had persisting HBP capture and thresholds of Conclusion Physicians adopting HBP should be cognizant of the learning curve and preferentially select non-dependent patients with normal QRS and LVEF, to minimize risk of lead revision. Further rises in HBP threshold may increase battery drain and need for reoperations, important considerations when choosing HBP for cardiac resynchronization therapy.
- Published
- 2021
- Full Text
- View/download PDF