1. ECG-based score estimates the probability to detect Fabry Disease cardiac involvement
- Author
-
Kelvin Chow, Massimo Lombardi, Paola Lusardi, Antonia Camporeale, Andrea Bernardini, Sara Boveri, Mehdi Namdar, Federico Pieruzzi, Alessandro P. Burlina, Marco Spada, Lara Tondi, Silvia Pica, Renzo Mignani, Maurizio Pieroni, Stefano Figliozzi, Francesca Graziani, Figliozzi, S, Camporeale, A, Boveri, S, Pieruzzi, F, Pieroni, M, Lusardi, P, Spada, M, Mignani, R, Burlina, A, Graziani, F, Pica, S, Tondi, L, Bernardini, A, Chow, K, Namdar, M, and Lombardi, M
- Subjects
medicine.medical_specialty ,Intraclass correlation ,Magnetic Resonance Imaging, Cine ,Electrocardiography ,QRS complex ,Predictive Value of Tests ,Internal medicine ,medicine ,Humans ,cardiovascular diseases ,Probability ,Fabry disease ,Ejection fraction ,medicine.diagnostic_test ,Left bundle branch block ,business.industry ,Myocardium ,T1 mapping ,Nomogram ,medicine.disease ,Magnetic Resonance Imaging ,Cross-Sectional Studies ,Early Diagnosis ,Cine ,Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE ,Cohort ,cardiovascular system ,Cardiology ,Cardiovascular magnetic resonance ,Cardiology and Cardiovascular Medicine ,business - Abstract
Objectives To elaborate an ECG-based nomogram estimating the probability to detect cardiac involvement by cardiac magnetic resonance (CMR) in Fabry Disease (FD). Methods 119 FD patients and 26 healthy controls underwent ECG and CMR. Test (n = 88, 60%) and validation cohorts (n = 57, 40%) were randomly derived. Cardiac involvement was defined as the presence of low myocardial T1 value, a CMR-surrogate of myocardial glycosphingolipid storage. ECG changes associated with low T1 value were identified in the test cohort, included in the nomogram and then tested in the validation cohort. Results Sokolow-Lyon index (AUC = 0.769), ratio between P-wave and PR-segment durations (Pwave/PRsegment) (AUC = 0.778), QRS duration (AUC = 0.703), QT (AUC = 0.769) duration were independently associated with the presence of low T1 on CMR at multivariate analysis. An ECG-based nomogram including these four parameters was accurate in identifying patients with CMR evidence of glycosphingolipid storage (c-index of the derived-nomogram = 0.90 in the test group; 0.81 in the validation group). Conclusion We propose a practical ECG-based nomogram accurately estimating the probability to detect low T1 values by CMR in FD patients. The application of this tool in clinical practice could improve early detection of FD cardiac involvement.
- Published
- 2021