1. Advanced Analysis Techniques Improve Infant Bone and Body Composition Measures by Dual-Energy X-Ray Absorptiometry
- Author
-
Kathy George, John A. Shepherd, Michael Basar, Lynda Stranix-Chibanda, Markus J. Sommer, Amanda Zadzilka, Cynthia Mukwasi-Kahari, Cassidy Powers, George K. Siberry, and Bo Fan
- Subjects
0301 basic medicine ,medicine.medical_specialty ,Bone density ,030209 endocrinology & metabolism ,Bone and Bones ,Article ,03 medical and health sciences ,0302 clinical medicine ,Absorptiometry, Photon ,Region of interest ,Bone Density ,Medicine ,Humans ,Dual-energy X-ray absorptiometry ,Bone mineral ,medicine.diagnostic_test ,business.industry ,Infant, Newborn ,Infant ,Reproducibility of Results ,Bone area ,030104 developmental biology ,Cross-Sectional Studies ,Multicenter study ,Pediatrics, Perinatology and Child Health ,Lean body mass ,Body Composition ,Bone mineral content ,Radiology ,business ,Nuclear medicine - Abstract
Objective To evaluate a novel technique designed to reduce the negative impact of motion artifacts in infant dual-energy X-ray absorptiometry (DXA) scans. Study design Using cross-sectional data from a large multicenter study, we developed and tested advanced methods for infant scan analysis. Newborns (n = 750) received spine and whole-body DXA scans with up to 3 attempts to acquire a motion free scan. Precision of infant DXA was estimated from visits with multiple valid scans. Accuracy of regional reflection, fusion, and omission techniques was estimated by comparing modified scans to unmodified valid scans. The effectiveness of the acquisition and analysis protocol was represented by the reduction in rate of failure to acquire valid results from infant visits. Results For infant whole-body DXA, arm reflection and all fusion techniques caused no significant changes to bone mineral content, bone mineral density, bone area, total mass, fat mass, lean mass, and percentage fat. Leg reflection and arm/leg dual-reflection caused significant changes to total mass, but the percentage change remained small. For infant spine DXA, fusion and omission caused no significant changes. Advanced analysis techniques reduced the failure rate of whole-body scanning from 20.8% to 9.3% and the failure rate of spine scanning from 8.9% to 2.4%. Conclusions Advanced analysis techniques significantly reduced the impact of motion artifacts on infant DXA scans. We suggest this protocol be used in future infant DXA research and clinical practice.
- Published
- 2016