1. Assessing an aflatoxin exposure biomarker: Exploring the interchangeability and correlation between venous and capillary blood samples
- Author
-
Balaji Srinivasan, Shibani Ghosh, Patrick Webb, Stacy P. Griswold, Kathy S. Xue, Jia-Sheng Wang, and Saurabh Mehta
- Subjects
Adult ,Aflatoxin B1 ,Adolescent ,Lysine ,Middle Aged ,Biochemistry ,Young Adult ,Aflatoxins ,Albumins ,Carcinogens ,Humans ,Female ,Biomarkers ,General Environmental Science - Abstract
Exposure to dietary aflatoxins has been recognized as a potential threat to child nutrition and growth, in addition to being a known carcinogen. The ability to accurately assess concentration of aflatoxin in the blood of at-risk individuals is therefore very important to inform public health policies and on-the-ground programs around the world. Venous blood is frequently used to quantify biomarkers of exposure such as AFB1-lysine adducts. However, venous blood collection methods are invasive, requiring highly trained staff, which makes this method challenging to implement, especially in resource-limited settings. In contrast, capillary blood collection by fingerprick is less invasive and has the potential for application in point-of-need monitoring. The aim of this exploratory study was to investigate the correlation and interchangeability of capillary and venous human blood samples in the quantification of AFB1-lysine adduct concentration. A total of 72 venous and capillary blood samples were collected from 36 women of reproductive age (16-49 years) in northern Uganda. All sample specimens were analyzed using high-performance liquid chromatography with fluorescence detection. Regression analysis and Bland-Altman analysis were performed to compare AFB1-lysine concentrations between venous and capillary sample pairs. Bland-Altman analysis of albumin-normalized AFB1-lysine data-bias was -0.023 pg/mg-albumin and the 95% limits of agreement were 0.51 to -0.56 pg/mg-albumin for log-transformed data. There was a positive correlation between albumin-normalized venous and capillary AFB1-lysine concentrations with r of 0.71 (p .0001). A lack of any accepted clinical cutoff for aflatoxin exposure makes definition of an 'acceptable' limit for statistical analysis and comparison of methods challenging. Our data suggests a positive correlation between albumin-normalized AFB1-lysine concentrations in venous and capillary sample pairs, but relatively weak agreement and interchangeability based on Bland-Altman analysis.
- Published
- 2022